Insuwrap - PVC 1500 TNL - Underground Single Ply PVC Waterproofing Membrane

Verified by manufacturer 2 months ago

Saveto

Single-ply waterproofing membrane for underground structures.

Jump to:
BOS
+96611265 3334 Website

Application

Underground single ply PVC waterproofing membrane suitable for:

  • Tunnel lining.
  • Tanking of underground structures.
  • Projects in the MENA Region.

Description

Insuwrap PVC underground waterproofing membrane 1500 TNL is a calendered extruded high polymer waterproofing membrane (thickness 1.50 mm).


Features and benefits:

  • Safe application tools (no torch needed).
  • Easy to apply using hot air welding for joints. The joints are homogeneously welded (PVC to PVC). No sealant or chemicals are required for joints (overlaps).
  • No adhesives or primers are required for installation.
  • Self-extinguishing material - safe in case of fire.
  • Resistant to high-temperature fluctuations.

General information

Color

Grey

Finish

Smooth

Material

Polyvinyl chloride (PVC)

Shape

Other

Length

20000 mm

Width

2100 mm

Height

1.5 mm

Uniclass

Pr_25_57_51_66 Polymeric membranesPrimary

CAWS

J40/297 Waterproofing/ damp-proofing/ gas-retardant membrane

Specification data - Polymeric membranes

Material

Polyvinyl chloride (PVC).

Standard

To ASTM D7176.

Guidance for specification option:

Please refer to the CSI document for a full list of standards.

Performance characteristics

-

External fire performance

To ASTM E108, Pass (Class B).

Tensile properties

Tensile strength at break to ASTM D882, ≥ 15 kN/m.
Tensile modulus at 100% elongation to ASTM D882, ≥ 10 kN/m.
Elongation at break to ASTM D882, > 300%.

Guidance for specification option:

Soil Burial - Max Change (to ASTM G 160 Standard Practice for Evaluating Microbial Susceptibility of Nonmetallic Materials By Laboratory Soil Burial).

  • Break Strength: ≤ 2.5%.
  • Elongation: ≤ 12%.
  • Modulus at 100%: ≤ 17%.

Tear resistance

To ASTM D1004, ≥ 50 kN/m.

Width (minimum)

2100 mm.

Thickness (minimum)

1.5 mm.

Colour

Light grey.

Dimensional stability

To ASTM D1204, ≤ 1% (maximum).

Hydrostatic resistance

To ASTM D751, ≥ 290 kPa.

MolecularWeight

To ASTM D2124, 400 (average).

Puncture resistance

Pass.

Sustainability data

Country of material origin

Saudi Arabia

Country of product manufacture

Saudi Arabia

Material

Polyvinyl chloride (PVC)

BIM objects

BOS

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.

Find out more about the NBS BIM Object Standard.

Platform Compatible Version
Revit
-

1

IFC
-

1

Literature

Insuwrap PVC 1500 TNL TDS

Insuwrap PVC 1500 TNL TDS

CSI Thermoplastic Sheet Waterproofing - Insuwrap PVC 1500 TNL