NBS Source
I'm a manufacturer

Type RG Plus glazed acoustic movable wall

Verified by manufacturer 5 months ago

London Wall Design Ltd Third party certifications:
  • ISO 9001 Quality Management

    Certificate type

  • EPD

    EPD

    Certificate type

  • Constructionline

    Constructionline

    Certificate type

  • Acclaim Accreditation

    Certificate type

Framed acoustic glazed movable wall.

Jump to:
+44 (0)20 8391 8750 Website

Application

Suitable for internal use.

Description

Framed glass sliding stacking panel partition system.


Features and benefits:

  • Individually operated, top hung, aluminium framed glass panels, purpose made to suit any opening size.
  • Retractable top and bottom seals with telescopic jamb seals, all operated by removable crank handle.
  • Mechanically operated by worm screw drive.
  • Optional semi-electric operation
  • No floor track.
  • Height maximum: 4 m.


Acoustic performance:

  • Can be used to limit noise transmission between rooms.
  • Sound reduction ratings of either Rw 46 dB (laboratory tested) or Rw 50 dB (laboratory tested).

General information

Color

-

Manufacturer guidance

Aluminium frame powder coated to any standard RAL colour choice

Finish

Powder-coated

Guidance for specification option:

Powder coated to any standard RAL colour choice

Material

Glass

Steel

Shape

Rectangle

Length

Bespoke

Width

Bespoke

Height

Bespoke

Warranty description

Two year

Uniclass

Pr_25_71_57_80 Sliding stacking panel partitionsPrimary

CAWS

K30/76 Glazing for relocatable partitions

K30/480 Glazing for relocatable partitions

L20/545 Sliding stacking panel partitions

Specification data - Sliding stacking panel partitions

Performance

Sound reduction Rw 46 dB (laboratory tested).

Guidance for specification option:

Average achieved site insulation typically less than laboratory conditions.

Sound reduction Rw 50 dB (laboratory tested).

Guidance for specification option:

Average achieved site insulation typically less than laboratory conditions.

Manufacturer guidance

  • Can be used to limit noise transmission between rooms.
  • Insulation typically related to panel weight.

Operation

M – Manual.

SE – Semi electric.

Guidance for specification option:

Semi electric available with slimmer frame; consult manufacturer for details.

Dimensions (nominal)

-

Panel (average)

-

Width

Guidance for specification option:

Up to 1200 mm (maximum). Insert requirements.

Height

Guidance for specification option:

Up to 4000 mm (maximum). Insert requirements.

Thickness

103 mm.

Panels

-

Construction

NE (Standard panel).

TE (Telescopic element).

SE1 (Single inset pass door).

SE2 (Double inset pass door).

EE (Corner / junction panel).

DT (Full height hinged pass door).

Manufacturer guidance

  • Faceted layouts, corner panels, glazed pass door available.
  • Panels and wall jambs have interconnecting profiles.
  • Can be used in conjunction with Type 100 panels.

Finish as delivered

Double glazed.

Bunching

Single stack.

Double stack.

Bi-parting.

Ceiling angle trim

Not required.

Flush with underside of ceiling.

Guidance for specification option:

Two point suspension only.

Exposed 20 mm from underside of ceiling.

Guidance for specification option:

Single point suspension only.

Manufacturer guidance

Ceiling track profile:

  • Selection of material and profile by manufacturer, dependent on panel weight and other parameters. Consult manufacturer to confirm size.
  • Ceiling angle trim allows support of suspended ceiling edge.
  • 20 mm exposed angle trim required to avoid partition panels fouling ceiling when using TL 1 ‘E’ system single point suspension.

Partition assembly

As per manufacturer drawings SL – 111 and SL – 112.

Track

TL 1 ‘E’ system.

Guidance for specification option:

  • Straight runs only, panels stacked within opening.
  • Single track, single point suspension.

TL 2 ‘Za’ system.

Guidance for specification option:

  • Straight runs only.
  • Twin point guide roller suspension.
  • System, minimal panel stack.

TL 3 ‘Zb’ system.

Guidance for specification option:

  • Straight runs only.
  • Twin point guide roller suspension.
  • Panels stacked within opening to left or right of track.

TL 4 ‘Z’ system.

Guidance for specification option:

  • Straight runs only.
  • Twin point guide roller suspension.
  • Stacked in recess cupboard.

TL 5 ‘K’ system.

Guidance for specification option:

For 90° movement of panels away from main track, twin point cross roller suspension.

Show more

Manufacturer guidance

Layout.

Track finish

White.

Guidance for specification option:

Standard.

RAL.

Guidance for specification option:

Special order; insert requirement.

Edges

Powder-coated, RAL.

Guidance for specification option:

Insert requirement.

Fire performance

Non fire rated.

Jambs

Standard: Width 80 mm.

Telescopic jamb extended to 350 mm.

Sustainability data

Contains Red List materials

No

Country of material origin

Netherlands

Country of product manufacture

Netherlands

Recyclability

Metal parts can be separated and directed to material recycling. Theoretically, particle board can also be recycled by directing the panels to new production

Third party certifications

Third party certifications

ISO 9001 Quality Management

ISO 9001 Quality Management

ISO 9001 Parthos

EPD

EPD

Parthos EPD

Constructionline

Constructionline

Social Value Certificate Constructionline

 Acclaim Accreditation

Acclaim Accreditation

SSIP Acclaim

Literature

Type RG Plus

Type RG Plus