NBS Source
I'm a manufacturer

Type 80 movable acoustic wall

Verified by manufacturer 2 months ago

Movawall Systems Ltd Third party certifications:
  • ISO 9001 Quality Management

    Certificate type

  • Constructionline

    Constructionline

    Certificate type

Top hung movable acoustic wall, movable wall, folding partition, sliding folding partition, room divider, bi-fold doors, sliding door, operable wall

Jump to:
+44 (0)20 8391 8790 Website

Application

Suitable for internal use only.


Description

Movable acoustic folding wall.


Features and benefits:

  • Individually operated, top hung panels, purpose made to suit any opening size.
  • Retractable top and bottom seals, mechanically operated by worm screw drive.
  • No floor track.
  • Faceted layouts, corner panels, junction panels, glazing cut outs and pass doors available.

General information

Color

-

Manufacturer guidance

Standard Laminate, factory spray painted, fabric wrapped panels, high pressure laminate, veneer, white board, magnetic white board or to clients requirements

Finish

-

Manufacturer guidance

Standard Laminate, factory spray painted, fabric wrapped panels, high pressure laminate, veneer, white board, magnetic white board or to clients requirements

Material

Aluminium

Chipboard

Shape

Rectangle

Length

Bespoke

Manufacturer guidance

1200mm wide x 6000mm high maximum panel dimensions

Width

Bespoke

Manufacturer guidance

1200mm wide x 6000mm high maximum panel dimensions

Height

Bespoke

Warranty description

Two year

Uniclass

Pr_25_71_57_80 Sliding stacking panel partitionsPrimary

CAWS

K30/76 Glazing for relocatable partitions

K30/480 Glazing for relocatable partitions

L20/545 Sliding stacking panel partitions

Specification data - Sliding stacking panel partitions

Third party accreditation

To DIN EN ISO 140-3-95.

Performance

Up to Rw 50 dB, measured in accordance with EN ISO 140-3.

Guidance for specification option:

  • Can be used to limit noise transmission between rooms, using optional dense cladding, optional internal insulation. Type 80 panels have been tested to achieve sound reduction ratings of up to Rw 55 dB, measured in accordance with EN ISO 140-3.
  • Insulation typically related to panel weight. Average achieved site insulation typically less than laboratory conditions, due to flanking structures.
  • Can be used to control room sound absorption levels using optional fabric wrapped acoustic panels, or optional perforated/ slotted sound absorbent boards.

Operation

Manual.

Dimensions (nominal)

-

Panel (average)

-

Width

Guidance for specification option:

Up to 1230 mm (maximum). As standard, wider panels possible to special order; insert requirements.

Height

Guidance for specification option:

Up to 6000 mm (maximum). Insert requirement.

Track system

-

Ceiling flange finish

White.

Guidance for specification option:

As standard, spray painted.

RAL.

Guidance for specification option:

Spray painted, special order; insert requirement.

Wall jamb and abutments

Finished to match panels.

Panels

-

Construction

Aluminium frame with double skin cladding of high density chipboard.

Finish as delivered

Priming sheet ready for ‘on site’ decoration by others.

Guidance for specification option:

Insert details as required.

Standard laminate.

High pressure laminate.

Whiteboard laminate.

Magnetic whiteboard laminate.

Factory spray paint to RAL colour.

Guidance for specification option:

Insert requirement.

Veneer.

Guidance for specification option:

Insert details of species type and cut.

Client supplied fully finished boards.

Guidance for specification option:

Insert details as required.

Lacquered steel sheet to RAL colour.

Guidance for specification option:

Insert requirement.

Stretch fabric system.

Guidance for specification option:

Thickness and fabric specification by specifier; insert details as required.

Perforated sound absorbent board.

Guidance for specification option:

Perforation specification by specifier; insert details as required.

Slotted sound absorbent board.

Guidance for specification option:

Slot specification by specifier; insert details as required.

Back painted glass.

Magnetic back painted glass.

Fire rating for panels

Non fire rated.

Guidance for specification option:

Standard.

30 minute fire rated (no pass door).

60 minute fire rated (no pass door).

Manufacturer guidance

  • Available with optional fire separation construction.
  • Particular fire rating may not be available in all panel types and finishes.
  • Consult manufacturer prior to specification.

Fire performance

Not required.

Class 1 to BS 476.

Guidance for specification option:

Available with optional finish: Standard range rated Class 1 Surface Spread of Flame when tested to BS 476.

Class 0 to Approved Document B.

Guidance for specification option:

Available with optional finish: In accordance with Building Regulation Approved Document B.

Manufacturer guidance

  • Available with optional fire separation construction.
  • Particular fire rating may not be available in all panel types and finishes.
  • Consult manufacturer prior to specification.

Bunching

Single stack.

Double stack.

Bi - parting.

Stacking layout

TL 1 ‘E’ system

Guidance for specification option:

  • Straight runs only, panels stacked within opening.
  • Single track, single point suspension.

TL 2 ‘Za’ system

Guidance for specification option:

  • Straight runs only.
  • Twin point guide roller suspension.
  • Minimal panel stack.

TL 3 ‘Zb’ system

Guidance for specification option:

  • Straight runs only.
  • Twin point guide roller suspension.
  • Panels stacked within opening to left or right of track.

TL 4 ‘Z’ system

Guidance for specification option:

  • Straight runs only.
  • Twin point guide roller suspension.
  • Stacked in recess cupboard.

TL 5 ‘K’ system

Guidance for specification option:

  • For 90° movement of panels away from main track, twin point cross roller suspension.
  • Two point suspension.

Show more

Partition assembly

Refer to manufacturer drawings (SL – 101, SL – 801 and SL – 802), for disposition of specified elements.

Acoustic insulation

Rw 41 dB.

Guidance for specification option:

Weight: 26 kg/m²; Thickness: 85 mm with exposed edge profiles, 93 mm with concealed edge profiles.

Rw 44 dB.

Guidance for specification option:

Weight: 30 kg/m²; Thickness: 85 mm with exposed edge profiles, 93 mm with concealed edge profiles.

Rw 46 dB.

Guidance for specification option:

Weight: 35 kg/m²; Thickness: 85 mm with exposed edge profiles, 93 mm with concealed edge profiles.

Rw 48 dB.

Guidance for specification option:

Weight: 40 kg/m²; Thickness: 85 mm with exposed edge profiles, 93 mm with concealed edge profiles.

Rw 50 dB.

Guidance for specification option:

Weight: 50 kg/m²; Thickness: 85 mm with exposed edge profiles, 93 mm with concealed edge profiles.

Track profile

-

Manufacturer guidance

  • Selection of material and profile by manufacturer, dependent on panel weight and other parameters; consult manufacturer to confirm size.
  • Ceiling angle trim allows support of suspended ceiling edge.
  • 20 mm exposed angle trim required to avoid partition panels fouling ceiling when using TL 1 ‘E’ system single point suspension.

Panel Type

NE (Standard panel).

TE (Telescopic element): Telescopic closure panel.

Guidance for specification option:

One TE panel required at end of run for each opening.

SE1 (Single leaf inset pass door).

Guidance for specification option:

Select from: no vision panel/ with vision panel to client dimensions.

SE2 (Double leaf inset pass door): Includes head panel and jamb on hinge side of door.

Guidance for specification option:

Select from: no vision panel/ with vision panel to client dimensions.

EE (Corner/ junction panel): Corner, angle or T-junction panel.

Show more

Manufacturer guidance

Where panel varies within the partition assembly, insert identifiers for panels after each selection.

Track finish

White.

Guidance for specification option:

As standard, spray painted.

RAL.

Guidance for specification option:

Spray painted, special order; insert requirement.

Ceiling angle trim

None.

Flush with underside of ceiling.

Guidance for specification option:

Two point suspension only.

Exposed 20 mm from underside of ceiling.

Guidance for specification option:

Single point suspension only.

Edge profile

Exposed.

Concealed.

Panel vertical edge trim finish

Satin anodized aluminium.

Guidance for specification option:

Standard.

Powder-coated aluminium, RAL.

Guidance for specification option:

Insert requirement.

Vision panel

Not required.

Glazed panel, cut out to client dimensions.

Guidance for specification option:

Not available for NE (Standard panel), EE (Corner/ junction panel) or TE (Telescopic element).

Minimum margins apply; consult manufacturer for details.

Guidance for specification option:

Not available for NE (Standard panel), EE (Corner/ junction panel) or TE (Telescopic element).

Available with integral blinds.

Guidance for specification option:

Not available for NE (Standard panel), EE (Corner/ junction panel) or TE (Telescopic element).

Sustainability data

Contains Red List materials

No

Country of material origin

Sweden

Country of product manufacture

Sweden

Recyclability

Metal parts can be separated and directed to material recycling. Theoretically, particle board can also be recycled by directing the panels to new production

Third party certifications

ISO 9001 Quality Management

ISO 9001 Quality Management

ISO 9001 Winab

Constructionline

Constructionline

Social Value Certificate

Literature

Type 80

Type 80