Sliding stacking panel partition.

  • Individually operated, top hung panels, purpose made to suit any opening size.
  • Retractable top and bottom seals, able to deal with floor level differences up to 20 mm.
  • Mechanically operated by worm screw drive.
  • No floor track.
  • Curved layouts, corner panels, junction panels, glazing cutouts, matching recess doors to special order.
  • Suitable for internal use and for external use with appropriate choice of features.

General information
Specification data
Product Reference

Type 100

Partition assembly

See drawing ___

See schedule ___

Operation

E - Fully electric

M - Manual

SE - Semi electric

Bunching

Single stack

Bi - parting

Track -
Layout

E system

K system, offset stack

K system, behind reveal stack

K system, wall recess stack

K system, branch stack

K system, remote stacking

Z system, Za

Z system, Zb

Z system, cupboard stack

Track profile -
Type

For Full electric operation

For Manual or Semi - electric operation

Ceiling angle trim

None

Flush with underside of profile

Recessed 20 mm from underside of profile

Recessed ___ mm from underside of profile

Track finish

Aluminium, satin anodized

RAL 9010

Other RAL colours ___

Wall jamb

None

WAL

WAL, Independent

WAL, Special order

WL

WL, Independent

WL, Special order

Panel Type

DT ___

EE - angle ___

Glazed panel ___

LE

NE ___

SE1 ___

SE2 ___

Tee

TE ___

Pocket door

Acoustic insulation

Rw 40 dB

Rw 42 dB

Rw 45 dB

Rw 47 dB

Rw 51 dB

Rw 53 dB

Rw 55 dB

Rw 58 dB

Finish

Acoustic backed textile overcladding. Range, colour ___

Acoustic rigid overcladding. Perforation, finish ___

Acoustic stretched textile overcladding. Range, colour ___

Client supply finishing boards

Melamine. Range, colour, texture ___

Laminate. Range, colour, texture ___

Priming sheet

Sheet steel. Colour ___

Spray - painted cladding. Paint type, texture, colour ___

Veneer. Species, cut, finish ___

Non - standard ___

Panel vertical edge type

Concealed

Exposed

Panel vertical edge finish

PVC, colour ___

Aluminium, colour anodized, colour ___

Aluminium, RAL 9010

Aluminium, RAL colour ___

Aluminium, satin anodized

Pass door handle

None

With aluminium backplate, satin anodized

With pvc backplate, black colour

With pvc backplate, white colour

With stainless steel backplate, semi- matte

Standard product features

Panels:

  • Steel bracket frame with double skin cladding of 19 mm thick, three layer, high density chipboard. Wide range of panel finishes. Exposed or concealed panel edge profiles.

Panel size:

  • Height: Up to 10 m as standard. Higher panels possible to special order.
  • Width: Up to 1250 mm as standard. Wider panels possible to special order.
  • Panel with concealed edge profiles: thickness 105 mm.

Acoustic performance:

  • Can be used to limit noise transmission between rooms, using optional dense cladding, optional internal insulation. Type 100 panels have been tested to achieve sound reduction ratings of up to Rw 58 dB, measured in accordance with EN ISO 140 - 3. Insulation typically related to panel weight. Average achieved site insulation typically less than laboratory conditions, due to flanking structures.
  • Can be used to adjust room reverberation time using optional textile coverings or optional perforated overcladding.

Fire performance:

  • Available with optional fire separation construction. Particular fire rating may not be available in all panel types and finishes. Consult manufacturer prior to specification.
  • Available with optional finishes from standard range rated Class 1 Surface Spread of Flame when tested to BS476 or Class O, in accordance with Building Regulation Approved Document B.

Product Options

Partition Assembly:

Refer to drawing for disposition of specified elements.

Operation:

  • M. Manual relocation of panels. Seals operated by removable winding handle.
  • SE. Semi-electric. Manual relocation of panels. Horizontal and vertical seals activated by 24 v electric motors concealed within panel thickness. Electrical supply to panels conducted through contacts in panel edge profiles. Remote master switching (to be within sight of TE panel, for safety). Each panel requires two - point suspension.
  • E. Fully electric. Seals activated as for Semi - electric. Electric relocation of panels by motors within trolleys, housed within special track type. Each panel requires two - point suspension. Power to trolleys conducted via busbars within track.
  • Mains connection by main contractor: 240V 13 AMP with isolated breaker and fused spur adjacent to London Wall control box, below ceiling level and adjacent to TE panel.

Track layout:

E system. Straight runs only, panels stacked within opening. Single track, single point suspension. Four wheel hanger.

K system. For 90° movement of panels away from main track, for remote panel stacking. Twin point cross roller suspension. Ball bearing solid housing hanger.

  • K system, offset stack within opening.
  • K system, behind reveal stack.
  • K system, wall recess stack.
  • K system, branch stack.

Z system - straight runs only. Twin point guide roller suspension. Four wheel hanger.

  • Za system. With 100 mm offset to left or right of track.
  • Zb system. Panels stacked within opening, to left or right of track.
  • Z system, cupboard stack.

Track profile:

  • Selection of material and profile by manufacturer, dependent on panel weight and other parameters. Consult manufacturer to confirm size.
  • Ceiling angle trim allows masking of suspended ceiling edge.
  • 20 mm recessed angle trim required to avoid partition panels fouling ceiling when using E system single point suspension.
  • Recessed angle trim may be advisable in other applications, dependent on panel width and pattern of use.

Wall jamb:

Finished to match panels.

  • None. Requires NE or TE panel with optional bulb seal.
  • WAL. Wall jamb, not for panel stacking. For fixing to wall.
  • WAL, Independent. Wall jamb, not for panel stacking. For fixing to floor and ceiling.
  • WAL, Special order. Wall jamb, not for panel stacking, precut to wall profile. For fixing to wall.
  • WL. Wall jamb for panel stacking.
  • WL, Independent. Wall jamb for panel stacking. For fixing to floor and ceiling.
  • WL, Special order. Wall jamb for panel stacking, precut to wall profile. For fixing to wall.

Panel type:

Where panel type varies within the partition assembly, insert identifiers for panels after each selection.

  • DT. Full height door. Full height hinged pass door panel. Fixed element, at end of run only. Includes jamb fixed to wall on hinge side of door. Reduces overall acoustic insulation of installation. Select from: unrated/ unrated with vision panel/ half hour fire rated.
  • EE. Corner, angle or T - junction panel.
  • Glazed panel. Glazed area to choice. Minimum margins apply. Select from: single glazed/ double glazed/ double glazed with blinds.
  • LE. Overlap panel.
  • NE. Standard panel.
  • SE1. Single leaf inset pass door panel. Reduces overall acoustic insulation of installation. Select from: plain/ with vision panel.
  • SE2. Double leaf inset pass door panel. Includes head panel and jamb on hinge side of door. Reduces overall acoustic insulation of installation. Select from: plain/ with vision panel.
  • TE. Telescopic closure panel. One TE panel required at end of run for each opening. External sleeve as standard, for optimum acoustic seal. Internal tongue optional, for visual neatness. Select from: external sleeve, internal tongue or internal tongue with bulb seal.
  • Pocket door. Choice of finishes as for panels.

Acoustic performance:

  • Can be used to adjust room reverberation time using optional textile coverings.
  • Can be used to limit noise transmission between rooms.
  • Tested to achieve sound reduction ratings of up to Rw 53 dB, measured in accordance with EN ISO 140 - 3.
  • Insulation typically related to panel weight. Average achieved site insulation typically less than laboratory conditions due to flanking structure.

Acoustic insulation:

Choose from construction offering the following nominal performance:

  • Rw 40 dB. Weight: 37 Kg/m².
  • Rw 42 dB. Weight: 40 Kg/m².
  • Rw 45 dB. Weight: 42 Kg/m².
  • Rw 47 dB. Weight: 45 Kg/m².
  • Rw 51 dB. Weight: 60 Kg/m².
  • Rw 53 dB. Weight: 64 Kg/m².
  • Rw 55 dB. Weight: 68 Kg/m².
  • Rw 58 dB. Weight: 75 Kg/m².

Panel finish:

Where panel type varies within the partition assembly, insert identifiers for panels after each selection.

  • Acoustic backed textile overcladding. With absorbant board backing. Applied on site.
  • Acoustic rigid overcladding. Choice of perforation, as standard. Choice of board finish, including veneers and spray paint, as standard. Additional panel thickness: 12 mm minimum.
  • Acoustic stretched textile overcladding. Tensioned over frame without backing. Applied on site.
  • Client supply finishing boards. Subject to weight, fixing type, spread of flame. Consult manufacturer.
  • Laminate. Manufacturer's colour range. RAL colours and woodgrains from Getalit range, as standard.
  • Melamine. Manufacturer's colour range. RAL colours and woodgrains from Getalan, as standard. Coated board.
  • Priming sheet. Applied sheet, ready for final finish by Contractor.
  • Sheet steel. Manufacturer's colour range. Spray painted.
  • Veneer. Manufacturer's range.

Panel vertical edge finish:

  • Aluminium, satin anodized aluminium. As standard.
  • Aluminium, powder coated RAL 9010. To match standard head track.
  • PVC. Low cost option. Available in brown, beige, white, grey.

Approvals:

  • Acoustic tests to DIN 52210 by Frauehofer Institute for Building Technology, Stuttgart.