NBS Source
I'm a manufacturer
Compare variants

Type 100 movable acoustic wall

Verified by manufacturer 5 months ago

DT Full height hinged pass door. Fixed element, at end of run only

London Wall Design Ltd Variant:
Third party certifications:
  • ISO 9001 Quality Management

    Certificate type

  • EPD

    EPD

    Certificate type

  • Constructionline

    Constructionline

    Certificate type

  • Acclaim Accreditation

    Certificate type

Top hung movable acoustic wall.

Jump to:
+44 (0)20 8391 8750 Website

Application

To limit noise transmission between rooms.

Description

Sliding stacking panel partition.


Features and benefits:

  • Individually operated, top hung panels, purpose made to suit any opening size.
  • Retractable top and bottom seals, able to deal with uneven floor levels.
  • Manual, semi-electric or fully electric options.
  • No floor track.
  • Faceted layouts, corner panels, junction panels, glazing cutouts, pass door options available.

General information

Color

-

Manufacturer guidance

Standard Laminate, factory spray painted, fabric wrapped panels, high pressure laminate, veneer, white board, magnetic white board or to clients requirements

Finish

-

Manufacturer guidance

Standard Laminate, factory spray painted, fabric wrapped panels, high pressure laminate, veneer, white board, magnetic white board or to clients requirements

Material

Aluminium

Glass

Shape

Rectangle

Length

Bespoke

Manufacturer guidance

1200mm wide x 20000mm high maximum panel dimension

Width

Bespoke

Manufacturer guidance

1200mm wide x 20000mm high maximum panel dimension

Warranty description

Two year

Uniclass

Pr_25_71_57_80 Sliding stacking panel partitionsPrimary

CAWS

K30/76 Glazing for relocatable partitions

K30/480 Glazing for relocatable partitions

L20/545 Sliding stacking panel partitions

Specification data - Sliding stacking panel partitions

Performance

Up to 60 dB to EN ISO 140-3.

Guidance for specification option:

  • Can be used to limit noise transmission between rooms, using optional dense cladding, optional internal insulation. Type 100 panels have been tested to achieve sound reduction ratings of up to Rw 60 dB, measured in accordance with EN ISO 140-3.
  • Insulation typically related to panel weight. Average achieved site insulation typically less than laboratory conditions, due to flanking structures.
  • Can be used to control room sound absorption levels using optional fabric wrapped acoustic panels or optional perforated/ slotted sound absorbent boards.

Operation

E: Fully electric.

Guidance for specification option:

  • Horizontal and vertical seals activated by 24 V electric motors concealed within panel thickness.
  • Electric relocation of panels by motors within trolleys, housed within special track type.
  • Each panel requires two-point suspension.
  • Power to trolleys conducted via busbars within track.
  • Mains connection by main contractor: 240 V,13 A with isolated breaker and fused spur adjacent to London Wall control box, below ceiling level and adjacent to TE panel.


M: Manual.

Guidance for specification option:

  • Manual relocation of panels.
  • Seals operated by removable winding handle.


SE: Semi-electric.

Guidance for specification option:

  • Manual relocation of panels.
  • Horizontal and vertical seals activated by 24 V electric motors concealed within panel thickness.
  • Electrical supply to panels conducted through contacts in panel edge profiles.
  • Remote master switching (to be within sight of TE panel, for safe operation.
  • Mains connection by main contractor: 240 V,13 A with isolated breaker and fused spur adjacent to London Wall control box, below ceiling level and adjacent to TE panel.


Dimensions (nominal)

-

Panel (average)

-

Width

Guidance for specification option:

Up to 1230 mm (maximum). Wider panels possible to special order; insert requirements.

Height

Guidance for specification option:

Minimum: 1.5 m up to 15 m *maximum); insert requirements.

Thickness

19 mm.

Track system

-

Wall jamb and abutments

Finished to match panels as standard.

Manufacturer guidance

  • Can be supplied without wall jambs in special cases.
  • Independent wall jamb available in instances where wall structure unsuitable for standard wall jamb.
  • Fixed to structural floor and soffit.

Panels

-

Construction

Internal bracket frame with double skin cladding of 19 mm thick, three layer, high density chipboard.

Finish as delivered

Back painted glass.

Client supplied fully finished boards.

Guidance for specification option:

Insert details as required.

Factory spray paint to RAL colour.

Guidance for specification option:

Insert requirement.

High pressure laminate.

Lacquered steel sheet to RAL colour.

Guidance for specification option:

Insert requirement.

Magnetic back painted glass.

Magnetic whiteboard laminate.

Perforated sound absorbent board.

Guidance for specification option:

Perforation specification by specifier; insert details as required.

Priming sheet ready for ‘on site’ decoration by others.

Guidance for specification option:

Insert details as required.

Slotted sound absorbent board.

Guidance for specification option:

Slot specification by specifier; insert details as required.

Standard laminate.

Stretch fabric system.

Guidance for specification option:

Thickness and fabric specification by specifier; insert details as required.

Veneer.

Guidance for specification option:

Insert details of species type and cut.

Whiteboard laminate.

Manufacturer guidance

Where panel type varies within the partition assembly, insert identifiers for panels after each selection.

Panel Type

Full height hinged pass door.

Guidance for specification option:

  • Fixed element, at end of run only.
  • Includes jamb fixed to wall on hinge side of door.
  • Select from: no vision panel/ with vision panel to client dimensions.

Track profile

-

Manufacturer guidance

  • Selection of material and profile by manufacturer, dependent on panel weight and other parameters; consult manufacturer to confirm size.
  • Ceiling angle trim allows support of suspended ceiling edge.
  • 20 mm exposed angle trim required to avoid partition panels fouling ceiling when using TL 1 ‘E’ system single point suspension.


Track layout

TL 1 ‘E’ system.

Guidance for specification option:

  • Straight runs only, panels stacked within opening.
  • Single track, single point suspension.

TL 2 ‘Za’ system.

Guidance for specification option:

  • Straight runs only.
  • Twin point guide roller suspension.
  • Minimal panel stack.

TL 3 ‘Zb’ system.

Guidance for specification option:

  • Straight runs only.
  • Twin point guide roller suspension.
  • Panels stacked within opening to left or right of track.

TL 4 ‘Z’ system.

Guidance for specification option:

  • Straight runs only.
  • Twin point guide roller suspension.
  • Stacked in recess cupboard.

TL 5 ‘K’ system.

Guidance for specification option:

  • For 90° movement of panels away from main track, twin point cross roller suspension.
  •  Two point suspension.

Show more

Manufacturer guidance

Please note: If Type TL1 'E' track is specified then Rw 58dB (laboratory tested) sound reduction and Rw 60dB (laboratory tested) sound reduction is not suitable.

Fire performance

Class 1 to BS 476.

Guidance for specification option:

Available with optional finish from standard range rated Class 1 Surface Spread of Flame, when tested to BS 476.

Class 0 to Approved Document M.

Guidance for specification option:

In accordance with Building Regulation (E&W) Approved Document B.

Manufacturer guidance

  • Particular fire rating may not be available in all panel types and finishes; consult manufacturer prior to specification.
  • Available with optional fire separation construction.

Partition assembly

Refer to manufacturer drawing (SL – 101, SL – 102 and SL – 103), for disposition of specified elements.

Panel vertical edge type

Concealed.

Exposed.

Bunching

Bi–parting.

Double stack.

Single stack.

Acoustic insulation

Rw 37 dB.

Rw 41 dB.

Rw 43 dB.

Rw 44 dB.

Rw 45 dB.

Show more

Manufacturer guidance

Please note: If the Rw 58dB or Rw 60dB value is specified, then Type TL 1 'E' track single point suspension is not suitable.

FireRating

Not fire rated.

Guidance for specification option:

Standard.

30 minute fire rated.

60 minute fire rated (no pass door).

Ceiling angle trim

None.

Exposed 20 mm from underside of ceiling.

Guidance for specification option:

Single point suspension only.

Flush with underside of ceiling.

Guidance for specification option:

Two point suspension only.

Track finish

White.

Guidance for specification option:

As standard, spray painted.

RAL.

Guidance for specification option:

Spray painted, special order; insert requirement.

Powder-coated aluminium, RAL.

Guidance for specification option:

Insert requirement.

Satin anodized aluminium.

Guidance for specification option:

Standard.

Sustainability data

Country of material origin

-

Manufacturer guidance

Germany, Holland or Sweden

Country of product manufacture

-

Manufacturer guidance

Germany, Holland or Sweden

Material

Aluminium

Glass

Recyclability

Metal parts can be separated and directed to material recycling. Theoretically, particle board can also be recycled by directing the panels to new production

Third party certifications

Third party certifications

ISO 9001 Quality Management

ISO 9001 Quality Management

ISO 9001 Abopart

ISO 9001 Quality Management

ISO 9001 Quality Management

ISO 9001 Parthos

ISO 9001 Quality Management

ISO 9001 Quality Management

ISO 9001 Winab

EPD

EPD

Parthos EPD

Constructionline

Constructionline

Social Value Certificate Constructionline

 Acclaim Accreditation

Acclaim Accreditation

SSIP Acclaim

Literature

Type 100

Type 100

Case studies

Type 100 Fully Electric - London School of Hygiene

Type 100 Fully Electric - London School of Hygiene

Type 100 - Longwater Reading

Type 100 - Longwater Reading

Type 100SE and Type G100 Combination - QEII Centre

Type 100SE and Type G100 Combination - QEII Centre

Type 100SE - Radiation Protection

Type 100SE - Radiation Protection

London Wall Design Ltd - Showroom