TUFF-DOR 3 Single

TUFF-DOR 3 Single

Third party certifications:
  • Secured By Design

    Secured By Design

    Certificate type

  • QA Certificate

    QA Certificate

    Certificate type

Robust UK Ltd

LPS 1175 SR3 certified, single leaf, steel security doorset.

Jump to:
+44 (0)1782 592900 www.robust-uk.com
Application

Provides up to five minutes of resistance to experienced attempts at forced entry using a wide range of tools including high powered cordless tools, felling axe, sledgehammer, power drill, disc grinder, jigsaw, etc.

Description

Single leaf, fully certified LPS 1175 SR3 steel security doorset designed to offer an enhanced level of security for a wide range of premises, from domestic or light commercial premises through to those at high risk of attack by experienced intruders.

Applications:

Provides up to five minutes of resistance to experienced attempts at forced entry using a wide range of tools including high powered cordless tools, felling axe, sledgehammer, power drill, disc grinder, jigsaw, etc.

General information

Uniclass 2015

Pr_30_59_24_37 High-security doorsetsPrimary

CAWS

L20/480 Doorsets

L20/55 Doorsets

Specification data - High-security doorsets

Product Reference

TUFF-DOR 3 Single

Size (w x h)

As drawing

Insert reference.

As schedule

Insert reference.

Finish/ Colour

Insert requirements, contact manufacturer for information.

Vision panels

Not required

170 x 370 mm

Louvre panels

Not required

400 x 450 mm

400 x 675 mm

400 x 450 mm and 400 x 675 mm

Not permitted with panic hardware.

Ironmongery

Insert requirements, contact manufacturer for information.

Standard product features

Door leaf:

- Construction:

Welded Aluzinc sheets around a solid timber core.

- Thickness:

59 mm.

Door frame:

- Construction:

Welded Aluzinc sheets.

- Depth:

115 mm.

Intruder resistance (to LPS 1175):

SR3.

Product Options

Size (w x h):

Available up to 1300 x 2500 mm.

Clearance requirements:

  • Strike: 3 mm.
  • Hinge: 13 mm.
  • Meeting stile: 5 mm.
  • Head: 3 mm.
  • Floor: 5 mm.

Wall construction:

The opening must be fully formed from a material with sufficient composition strength to withstand a minimum load/ fixing of 7 N/nm² (such as concrete or brick). Aerated concrete is not recommended, and hollow brick/ block should only be considered if suitably backfilled with materials that will provide adequate strength (7 N/nm²) to take the frame fixings.

Third party certifications
  • Certified
  • Loss Prevention Certification Board (LPCB): Certificate: 1070A : Certified to LPS 1175