Verified by manufacturer 2 days ago
Titane Next 75 Door and Framing System - Entrance Door
CAB Closed Loop Recycling Scheme
Certificate type
EPD
Certificate type
Secured By Design
Certificate type
A commercial building aluminium door solution.
Suitable for use in school and commercial environments.
TITANE Next offers a blend of durability, aesthetics and functionality for high-traffic commercial spaces. Extruded with aluminium made with at least 75% recycled post-consumer scrap, it delivers thermal performance, security, and long-lasting durability. Customisable finishes and large dimensions allow it to enhance any commercial property, while its low-maintenance design ensures reliability in demanding environments.
Features and benefits:
Finish | Powder-coated Anodized |
Material | Aluminium Polyamide Acrylonitrile butadiene styrene (ABS) |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Uniclass | |
CAWS | L20/55 Doorsets L20/480 Doorsets |
Manufacturer | Technal. |
Standard | External non-fire-rated aluminium alloy doorset to BS 4873 and UKCA/ UKNI/ CE marked in accordance with BS EN 14351-1. |
Configuration | Double-leaf, single-action. Double-leaf, double-action. Leaf and part-leaf, single-action. Leaf and part-leaf, double-action. Single-leaf, single-action. Single-leaf, double-action. |
Doorset size | Manufacturer guidanceMaximum size 1500 x 3000 mm. Insert requirements or refer to a drawing or schedule. |
Performance | |
Strength and durability | To BS EN 1191:2012, Class 7. Guidance for specification option: 500 000 cycles. Class 1 in accordance with EN 12046-1; Class 4 in accordance with EN 12046-1. |
Thermal | 1.6 W/m²K. Guidance for specification option: With 1.0 W/m²K DGU. 1.2 W/m²K. Guidance for specification option: With 0.5 W/m²K TGU. |
Intruder resistance | |
Minimum requirement | To PAS 24. Secured by Design certification. |
Frame | |
Material | Aluminium. Guidance for specification option:
|
Threshold | Approved Doc M approved. |
Perimeter seals or inserts | EPDM membranes, ≤ 250 mm width. Guidance for specification option: In accordance with CWCT/ SFE 'Technical Guidance for interpretation in relation to external walls and specified attachments of Relevant Buildings in England issue 2, July 2023'. |
Finish | |
Coating | Powder coating to BS EN 12206-1. Guidance for specification option: Any special warranties or guarantees (such as marine or industrial/ chlorine) to be issued directly by the powder supplier and agreed prior to material order. Anodizing to BS 3987. Manufacturer guidanceAll finishing to be undertaken by Hydro Building Systems prior to delivery to the manufacturer. |
Texture | Gloss. Matt. Satin. |
Colour | Standard Technal finish. Manufacturer guidanceStandard Technal finish (RAL, gloss level and classification TBC) from standard Technal range. Consult manufacturer and insert requirements. |
Door leaf | |
Thickness | 75 mm. |
Panel details | Solid infill and spandrel panels to be tested and classified to Class A2-s1, d0 or A1 according to BS EN 13501 1:2007+A1:2009 for reaction to fire. Panel U-value to be 1.0 W/m²K (or less). Panels to have rigid edges. Guidance for specification option: External facing, internal facing and insulation: Consult manufacturer and insert requirements. |
Material | Aluminium. |
Glazing | |
Type | Double-glazed units. Guidance for specification option:
|
Manifestation | Not required. Required. Guidance for specification option: Manifestation design and location to be confirmed by the contract administrator. Recommendations of the Glass and Glazing Federation should be adhered to. Insert requirements or refer to a drawing. |
Beading | |
Type | Internal. Guidance for specification option: For doors and fixed panels. External. Guidance for specification option: For fixed panels only. Manufacturer guidanceSquare. |
Finish | |
Coating | Powder coating to BS EN 12206-1. Guidance for specification option: Any special warranties or guarantees (such as marine or industrial/ chlorine) to be issued directly by the powder supplier and agreed prior to material order. Anodizing to BS 3987. Manufacturer guidanceAll finishing to be undertaken by Hydro Building Systems prior to delivery to the manufacturer. |
Texture | Gloss. Matt. Satin. |
External colour | Standard Technal finish. Manufacturer guidanceStandard Technal finish (RAL, gloss level and classification TBC) from standard Technal range. Consult manufacturer and insert requirements. |
Internal colour | Standard Technal finish. Manufacturer guidanceStandard Technal finish (RAL, gloss level and classification TBC) from standard Technal range. Consult manufacturer and insert requirements. |
UK exposure category | 1200 Pa. Guidance for specification option: Notwithstanding any information within this specification, all framing and infills shall be capable of withstanding the design wind loadings calculated in accordance BS EN 1991-1-4, and imposed loads as defined in BS EN 1991-1-1, and the specialist contractor shall carry out calculations to demonstrate this. |
Air permeability | To EN 14351-1+A1, Class 2 (300 Pa). |
Watertightness | To EN 14351-1+A1, Class E3A (100 Pa). |
Resistance to wind load | To EN 14351-1+A1, Class C3 (1200 Pa). |
Louvres | Glazed-in louvres to be tested and classified to Class A2-s1, d0 or A1 according to BS EN 13501-1:2007+A1:2009 for reaction to fire. Guidance for specification option: Blades, surface finish, fixing: Consult manufacturer and insert requirements. |
Closers | Technal Part M compliant concealed overhead closers TPZ60510 with 90° hold open facility. Technal Part M compliant concealed overhead closers TPZ60511 without hold open facility. Manufacturer guidanceCloser strength selected to be compatible with physical capabilities of users and be adjustable from EN2–EN5. Closing speed and latching speed to be adjustable. |
Locking | TPZ63234 Hook bolt deadlock operated by double cylinder. TPZ63234 Hook bolt deadlock operated by cylinder thumb turn. |
Locking/ handles | Inactive leaf: 2-point lever handle operated mortise shoot bolts lock with internal rod TPZ63815. |
Third-party certification | BM Trada Q Mark, UL, IFT. |
FrameMaterial | Recycled content: Minimum of 75% recycled end-of-life aluminium (post-consumer scrap). |
Verification | Submit EcoPlatform third party published EPD conforming to ISO 14025 and EN 15804+A2. Proof of calculation of U-values to EN 10077-2 to be provided by specialist contractor. |
Contains Red List materials | No |
Country of material origin | United Kingdom |
Material | Aluminium Polyamide Acrylonitrile butadiene styrene (ABS) |
A1-A3 (production stage) | Embodied carbon as defined in BS EN 15804 |
Normalised unit | 1.9 kg CO₂ eq/kg |
Declared unit | 1.9 kg CO₂ eq/kg Certified Lower emissions |
Recyclability | 95% |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 75 % |
Expected Life | 50 year |
Certified