NBS Source
I'm a manufacturer
Compare variants

TITANE Next 75 Commercial door

Verified by manufacturer 2 days ago

Titane Next 75 Door and Framing System - Entrance Door

Technal Variant:
Product certifications:
  • CAB Closed Loop Recycling Scheme

    Certificate type

  • EPD

    EPD

    Certificate type

  • Secured By Design

    Secured By Design

    Certificate type

A commercial building aluminium door solution.

Jump to:
+44 (0)1684 853 500 Website

Application

Suitable for use in school and commercial environments.

Description

TITANE Next offers a blend of durability, aesthetics and functionality for high-traffic commercial spaces. Extruded with aluminium made with at least 75% recycled post-consumer scrap, it delivers thermal performance, security, and long-lasting durability. Customisable finishes and large dimensions allow it to enhance any commercial property, while its low-maintenance design ensures reliability in demanding environments.

Features and benefits:

  • Sustainable design: Made with Hydro CIRCAL 75R® as standard, and Hydro CIRCAL 100R® on request, containing 75% recycled content and 95% recyclable components, TITANE Next aligns with eco-conscious building practices while maintaining a low carbon footprint across its entire lifecycle. 
  • High performance: U-values as low as 0.79 W/m²K, weather resistance, and durability tested up to 500 000 cycles, ensuring reliable performance in high-traffic environments.
  • Versatile applications: Adaptable to various configurations, including single/ double-leaf, panic exit and electomagnetic lock setups, it suits a range of architectural and functional needs.
  • Customisable aesthetics: Concealed hardware, a variety of finish options, and the ability to accommodate large dimensions.
  • Can incorporate single or double doors and automated sliding doors, designed for entrance screens and facades where compliance with The Building Regulations (E&W) Part L is required.
  • Can be used in conjunction with Technal curtain walling, windows and doors – consult manufacturer for details.
  • Thermally broken with polyamide strips.
  • Fully weather tested.

General information

Finish

Powder-coated

Anodized

Material

Aluminium

Polyamide

Acrylonitrile butadiene styrene (ABS)

Length

Bespoke

Width

Bespoke

Height

Bespoke

Uniclass

Pr_30_59_24_02 Aluminium doorsetsPrimary

CAWS

L20/55 Doorsets

L20/480 Doorsets

Specification data - Aluminium doorsets

Manufacturer

Technal.

Standard

External non-fire-rated aluminium alloy doorset to BS 4873 and UKCA/ UKNI/ CE marked in accordance with BS EN 14351-1.

Configuration

Double-leaf, single-action.
Double-leaf, double-action.
Leaf and part-leaf, single-action.
Leaf and part-leaf, double-action.
Single-leaf, single-action.
Single-leaf, double-action.

Doorset size

-

Manufacturer guidance

Maximum size 1500 x 3000 mm. Insert requirements or refer to a drawing or schedule.

Performance

-

Strength and durability

To BS EN 1191:2012, Class 7.

Guidance for specification option:

500 000 cycles.

Class 1 in accordance with EN 12046-1; Class 4 in accordance with EN 12046-1.

Thermal

1.6 W/m²K.

Guidance for specification option:

With 1.0 W/m²K DGU.

1.2 W/m²K.

Guidance for specification option:

With 0.5 W/m²K TGU. 

Intruder resistance

-

Minimum requirement

To PAS 24.
Secured by Design certification.

Frame

-

Material

Aluminium.

Guidance for specification option:

  • All frames and other sections to be extruded to EN 12020, EN 573-3, EN 515 and EN 775-1 to 9 from aluminium alloy specification 6060 T66 comprising a minimum of 75% recycled end-of-life aluminium (post-consumer scrap) and a GWP (A1-A3) of no greater than 1.9 kg of CO2e/kg of aluminium. Provide EcoPlatform third party published EPD conforming to ISO 14025 and EN 15804+A2 to confirm the above.
  • All aluminium billets and extrusions to be sourced from cast house and extrusion plants certified by Aluminium Stewardship Initiative (ASI) for Performance Standard and Chain of Custody Standard.
  • Thermal break comprising glass reinforced recycled polyamide extrusions PA66 GF25 mechanically jointed to form a single compound profile.
  • The thermal break is to be applicable to all profiles, including vents, couplers and cills.

Threshold

Approved Doc M approved.

Perimeter seals or inserts

EPDM membranes, ≤ 250 mm width.

Guidance for specification option:

In accordance with CWCT/ SFE 'Technical Guidance for interpretation in relation to external walls and specified attachments of Relevant Buildings in England issue 2, July 2023'.

Finish

-

Coating

Powder coating to BS EN 12206-1.

Guidance for specification option:

Any special warranties or guarantees (such as marine or industrial/ chlorine) to be issued directly by the powder supplier and agreed prior to material order.

Anodizing to BS 3987.

Manufacturer guidance

All finishing to be undertaken by Hydro Building Systems prior to delivery to the manufacturer.

Texture

Gloss.
Matt.
Satin.

Colour

Standard Technal finish.

Manufacturer guidance

Standard Technal finish (RAL, gloss level and classification TBC) from standard Technal range. Consult manufacturer and insert requirements.

Door leaf

-

Thickness

75 mm.

Panel details

Solid infill and spandrel panels to be tested and classified to Class A2-s1, d0 or A1 according to BS EN 13501 1:2007+A1:2009 for reaction to fire. Panel U-value to be 1.0 W/m²K (or less). Panels to have rigid edges.

Guidance for specification option:

External facing, internal facing and insulation: Consult manufacturer and insert requirements.

Material

Aluminium.

Glazing

-

Type

Double-glazed units.

Guidance for specification option:

  • Glazing to be hermetically sealed double-glazed units, in accordance with Building Regulations.
  • Glazing to windows to be secured by means of glazing beads.
  • Composition of units to be confirmed, with laminated low-e clear glass inner pane (to BS EN 356:2000 P1A where required for PAS 24 compliance).
  • Where self-cleaning coating is applied to the external pane, use non-silicone lubricated gasket. Specialist contractor to supply confirmation from glass supplier of gasket compatibility.
  • All glass and glazing shall conform to:
    • BS EN 12600:2002.
    • BS EN 1279.
  • All glazing in WCs and bathrooms shall have obscured glass to the inner pane.
  • All glass within 800 mm from FFL shall be toughened or laminated. (Below 1500 mm if within a door or 300 mm of a door).
  • Heat soak test all toughened glass used as outer pane above ground floor or in all overhead glazing in accordance with BS EN 14179.
  • Carry out thermal safety check to all glazing.
  • Full height barrier glazing to comply with BS 6180:2011, Code of Practice in respect of relevant point, U.D.L and line loads.

Manifestation

Not required.
Required.

Guidance for specification option:

Manifestation design and location to be confirmed by the contract administrator. Recommendations of the Glass and Glazing Federation should be adhered to. Insert requirements or refer to a drawing.

Beading

-

Type

Internal.

Guidance for specification option:

For doors and fixed panels.

External.

Guidance for specification option:

For fixed panels only.

Manufacturer guidance

Square.

Finish

-

Coating

Powder coating to BS EN 12206-1.

Guidance for specification option:

Any special warranties or guarantees (such as marine or industrial/ chlorine) to be issued directly by the powder supplier and agreed prior to material order.

Anodizing to BS 3987.

Manufacturer guidance

All finishing to be undertaken by Hydro Building Systems prior to delivery to the manufacturer.

Texture

Gloss.
Matt.
Satin.

External colour

Standard Technal finish.

Manufacturer guidance

Standard Technal finish (RAL, gloss level and classification TBC) from standard Technal range. Consult manufacturer and insert requirements.

Internal colour

Standard Technal finish.

Manufacturer guidance

Standard Technal finish (RAL, gloss level and classification TBC) from standard Technal range. Consult manufacturer and insert requirements.

UK exposure category

1200 Pa.

Guidance for specification option:

Notwithstanding any information within this specification, all framing and infills shall be capable of withstanding the design wind loadings calculated in accordance BS EN 1991-1-4, and imposed loads as defined in BS EN 1991-1-1, and the specialist contractor shall carry out calculations to demonstrate this.

Air permeability

To EN 14351-1+A1, Class 2 (300 Pa).

Watertightness

To EN 14351-1+A1, Class E3A (100 Pa).

Resistance to wind load

To EN 14351-1+A1, Class C3 (1200 Pa).

Louvres

Glazed-in louvres to be tested and classified to Class A2-s1, d0 or A1 according to BS EN 13501-1:2007+A1:2009 for reaction to fire.

Guidance for specification option:

Blades, surface finish, fixing: Consult manufacturer and insert requirements.

Closers

Technal Part M compliant concealed overhead closers TPZ60510 with 90° hold open facility.

Technal Part M compliant concealed overhead closers TPZ60511 without hold open facility.

Manufacturer guidance

Closer strength selected to be compatible with physical capabilities of users and be adjustable from EN2–EN5. Closing speed and latching speed to be adjustable. 

Locking

TPZ63234 Hook bolt deadlock operated by double cylinder.

TPZ63234 Hook bolt deadlock operated by cylinder thumb turn.

Locking/ handles

Inactive leaf: 2-point lever handle operated mortise shoot bolts lock with internal rod TPZ63815.

Third-party certification

BM Trada Q Mark, UL, IFT.

FrameMaterial

Recycled content: Minimum of 75% recycled end-of-life aluminium (post-consumer scrap).
Embodied carbon: GWP (A1-A3) of no greater than 1.9 kg of CO2e/kg of aluminium.

Verification

Submit EcoPlatform third party published EPD conforming to ISO 14025 and EN 15804+A2.

Proof of calculation of U-values to EN 10077-2 to be provided by specialist contractor.

Sustainability data

Contains Red List materials

No

Country of material origin

United Kingdom

Material

Aluminium
Polyamide
Acrylonitrile butadiene styrene (ABS)

A1-A3 (production stage)

Normalised unit

1.9 kg CO₂ eq/kg

Declared unit

1.9 kg CO₂ eq/kg

Certified

Lower emissions

Recyclability

95%

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

75 %

Expected Life

50 year

Product certifications

Certified

Product certifications

CAB Closed Loop Recycling  Scheme

CAB Closed Loop Recycling Scheme

CAB Closed Loop Scheme

EPD

EPD

Titane Next

Secured By Design

Secured By Design

Secured by Design - certficate

Literature

Titane Next Data Sheet

Titane Next Data Sheet

TITANE Next Aluminium Commercial Door - TECHNAL UK

TITANE Next Aluminium Commercial Door - TECHNAL UK

Similar products from Technal

SOLEAL Next 75 Sustainable Aluminium Door  - Aluminium Thermally Broken Door

SOLEAL Next 75 Sustainable Aluminium Door - Aluminium Thermally Broken Door

STII High Traffic Aluminium Commercial Door - Door

STII High Traffic Aluminium Commercial Door - Door