Verified by manufacturer 3 days ago
Janisol C4 Double Leaf Inward Opening
Fire door for demanding security requirements.
Suitable as a fire door.
A steel profile series with a basic depth of 70 mm offering the safety features of a fire protection system. Fire-resistant infill panels achieve resistance times of up to 90 minutes in accordance with DIN 4102, improve the security requirements and are easy to install due to the cable ducts supplied as standard in the Janisol C4 profile.
Features and benefits:
Standards:
Finish | Galvanized Guidance for specification option: Strip galvanized steel profiles. Natural Guidance for specification option: Uncoated. Powder-coated Enamelled Guidance for specification option: Stove enamelled. |
Material | Steel |
Width | Bespoke |
Height | Bespoke |
Uniclass | |
CAWS | L20/480 Doorsets L20/55 Doorsets |
Standard | To EN 16034. |
Third-party certification | EPD; CE Marking. |
Configuration | Double leaf inward opening. |
Doorset size | Manufacturer guidanceInsert requirements, up to 3000 x 1400 mm. Maximum weight: 350 kg. |
Performance | |
Fire resistance | |
Insulation | To EN 13501-2, EI60.To EN 13501-2, EI90. |
Smoke leakage | To EN 1634-3, S200. |
Acoustic performance | Manufacturer guidanceTo BS EN ISO 10140-2. Insert requirements, up to 43 dB. |
Strength and durability | To BS EN 1192, Class 4; to EN 1191, Class 6.Guidance for specification option: Durability: Up to one million cycles. |
Thermal | Manufacturer guidanceConsult manufacturer for details and insert requirements.
|
Frame | |
Material | Steel. |
Finish | |
Coating | Uncoated.Strip-galvanized.Guidance for specification option: Strip galvanised steel profiles. Powder coated.Stove enamelled. |
Colour | Manufacturer guidanceInsert requirements or omit as applicable for Coating specified. |
Installation fasteners | Manufacturer guidanceConsult manufacturer for details and insert requirements. |
Frame accessories | Manufacturer guidanceConsult manufacturer for details and insert requirements or omit. |
Door leaf | |
Thickness | 70 mm. |
Core | Manufacturer's standard.Guidance for specification option: To achieve specified performance. |
Panel details | Manufacturer's standard. |
Material | Steel. |
Glazing | |
Type | Manufacturer guidanceInsert requirements, up to 49 mm thick. Maximum glass panel size: 1400 x 2500 mm. |
Manifestation | Manufacturer guidanceConsult manufacturer for options and insert requirements or omit. |
Finish | |
Coating | As Frame. |
Texture | Manufacturer's standard. |
External colour | As Frame. |
Internal colour | As External. |
Film thickness (minimum) | Manufacturer's standard. |
Door accessories | Manufacturer guidanceConsult manufacturer for options and insert requirements or omit. |
Hardware | Manufacturer guidanceConsult manufacturer for options and insert requirements. |
Architraves | |
Material | Steel. |
Finish | As Frame. |
Accessories | Manufacturer guidanceConsult manufacturer for options and insert requirements or omit. |
Resistance to wind load | To EN 12210, Class 4. |
Watertightness | To EN 12208, 4A. |
Air permeability | To EN 12207, Class 4. |
Operating forces | To EN 12217, Class 2. |
Country of material origin | United Kingdom |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 23 % |
Platform | Compatible | Version |
---|---|---|
- | 1 |