Verified by manufacturer 15 hours ago
Terrain Q is a reliable alternative traditional noise reducing drainage systems. The multi-layer noise reducing system also provides increased fire retardancy with a classification of B-s1,d0.
Acoustic (noise reducing) drainage system. Terrain Q is a pipe system especially developed to be applied within the structure of multi-occupancy buildings.
Multi-layer acoustic drainage system with increased fire retardancy.
Terrain Q is a simple, reliable alternative to other traditional noise reducing drainage systems.
Features and benefits:
Color | Blue |
Finish | Smooth |
Material | Polypropylene |
Shape | Circle |
Length | 3000 mm |
Width | 40 mm 50 mm 75 mm 110 mm 160 mm Manufacturer guidancePipe diameter. |
Height | Bespoke Manufacturer guidancePipe diameter. |
Uniclass | |
CAWS | R11/115 Above ground foul drainage system R11/11 Plastics branch pipework R11/355 Polypropylene pipework |
Standard | To BS EN 1451-1, BS EN 14366. |
Jointing type | Push-fit ring seal. |
Nominal sizes | DN 40.Guidance for specification option: Thickness: 1.8 mm. Weight: 0.71 kg/unit. DN 50.Guidance for specification option: Thickness: 1.8 mm. Weight: 0.899 kg/unit. DN 75.Guidance for specification option: Thickness: 1.9 mm. Weight: 1.448 kg/unit. DN 110.Guidance for specification option: Thickness: 2.7 mm. Weight: 3.095 kg/unit. DN 160.Guidance for specification option: Thickness: 3.9 mm. Weight: 6.629 kg/unit. DN 200.Guidance for specification option: Thickness: 4.9 mm. Weight: 10.630 kg/unit. Manufacturer guidanceConsult manufacturer for further details. |
Colour | Blue.Guidance for specification option: External. White lining. |
Pipes | Single socket, 3 m long as standard. |
Bends | Bend, 15°. Guidance for specification option: DN 110 only. Bend, 30°. Guidance for specification option: DN 110 only. Bend, 45°. Guidance for specification option: Available for all nominal sizes. Bend, 87°. Guidance for specification option: Available for all nominal sizes. Double socket end, 45°. Guidance for specification option: DN 110 only. Manufacturer guidanceConsult manufacturer's literature for full details. Refer to drawing/ schedule and add details as required. |
Branches | Single branch, 45°. Guidance for specification option: Available for all nominal sizes. Single branch, 87°. Guidance for specification option: Available for all nominal sizes. Single reducing branch, 45°. Guidance for specification option: Insert requirements.
Single reducing branch, 87°. Guidance for specification option: Insert requirements.
Fully socketed branch, 45°, DN 110. Manufacturer guidanceRefer to drawing/ schedule and add details as required. |
Adaptors and reducers | Eccentric reducer. Guidance for specification option: Available for all nominal sizes. Short eccentric reducer. Guidance for specification option: Insert requirements:
Straight boss adaptor. Guidance for specification option: For use with 110 Terrain Q PVC branch; solvent weld to boss horn. Terrain Q to PVC adaptor, 40 mm to 1½". Guidance for specification option: For use with 110 Terrain Q PVC branch; to be specified with straight boss adaptor. Terrain Q to PVC adaptor, 50 mm to 2". Guidance for specification option: For use with 110 Terrain Q PVC branch; to be specified with straight boss adaptor. Manufacturer guidanceWhere applicable, consult manufacturer's literature for options and insert requirements/ further details as required. Refer to drawing/ schedule and add details as required. |
Connectors | Double depth socket. Guidance for specification option: DN 50 or 110 only. Slip coupler. Guidance for specification option: Available for all nominal sizes. Double socket. Guidance for specification option: Available for all nominal sizes. Socket plug. Guidance for specification option: Available for all nominal sizes. Manufacturer guidanceWhere applicable, consult manufacturer's literature for options and insert requirements/ further details as required. Refer to drawing/ schedule and add details as required. |
Access pipes | Access pipe with cap. Guidance for specification option: Consult manufacturer's literature for options and insert requirements. Not available for DN 40. Manufacturer guidanceWhere applicable, consult manufacturer's literature for options and insert requirements/ further details as required. Refer to drawing/ schedule and add details as required. |
Fire classification | To BS EN 13501, B-s1,d0. |
Brackets | All bracket types used in the Terrain Q system shall be specifically designed to reduce the passage of vibration from the pipe/ fitting surface in to the structure of the building. This can be achieved by the correct type of rubber lined bracket, the rubber lining being designed to optimize vibration de-coupling or, by de-coupling the connection rod back to the building structure by use of a proprietary anti-vibration bracket back-plate. |
Material | Polypropylene |