Verified by manufacturer 24 days ago
T 30-1-FSA, Teckentrup 62“
DAkkS
Certificate type
Commercially competitive integrity and insulation steel doors that have fire-proof, smoke-proof life safety performance - U value of 1.3 W(m2)K.
Insulated fire doors & doorsets.
T60-FSA:
A heavy-duty insulated steel fire door for front and back-of house applications and high traffic locations.
Features and benefits:
T90 DF FSA:
62 mm-thick, fire-proof steel door .
Features and benefits:
T 30-1-FSA
Steel fire-resistant door with thin-thick rebate 62 mm thick, fire proof steel door.
Features and benefits:
T30-2-FSA
Flush mounted door leaf with thin-thick rebate 62 mm thick, fire proof steel door.
Features and benefits:
Color | Grey Other Guidance for specification option: Coated to Any RAL colour. |
Finish | Powder-coated Satin Other Guidance for specification option: Marbled. |
Material | Steel Stainless steel |
Shape | Rectangle |
Width | 750 mm Guidance for specification option: T 30-1-FSA standard door width; consult manufacturer's literature for available heights. 875 mm Guidance for specification option: T 30-1-FSA standard door width; consult manufacturer's literature for available heights. 1000 mm Guidance for specification option: T 30-1-FSA standard door width; consult manufacturer's literature for available heights. 1125 mm Guidance for specification option: T 30-1-FSA standard door width; consult manufacturer's literature for available heights. 1250 mm Guidance for specification option: T 30-1-FSA standard door width; consult manufacturer's literature for available heights. |
Height | 1750 mm Guidance for specification option: T30-2-FSA special door height; consult manufacturer's literature for available widths. 1875 mm Guidance for specification option: T 30-1-FSA standard door height; consult manufacturer's literature for available widths. 2000 mm Guidance for specification option: T90 DF FSA, T 30-1-FSA and T30-2-FSA standard door height; consult manufacturer's literature for available widths. 2125 mm Guidance for specification option: T90 DF FSA, T 30-1-FSA and T30-2-FSA standard door height; consult manufacturer's literature for available widths. 2250 mm Guidance for specification option: T90 DF FSA, T 30-1-FSA and T30-2-FSA standard door height; consult manufacturer's literature for available widths. |
Warranty description | Manufacturer guidanceWarranty is subject to application, location and specification. Consult manufacturer for details. |
Uniclass | |
CAWS | L20/55 Doorsets L20/480 Doorsets |
SKU Code | T60-FSA, T90 DF FSA, T 30-1-FSA, T30-2-FSA |
Standard | To EN 1634-1, DIN 18095, DIN EN 20140, EN 1627/30, EN 1191, and EN ISO 12567-1. |
Configuration | Double leaf. Single leaf. |
Doorset size | 750 x 2000 mm. 750 x 2125 mm. 875 x 1875 mm. 875 x 2000 mm. 875 x 2125 mm. 1000 x 2000 mm. 1000 x 2125 mm. 1125 x 2000 mm. 1125 x 2125 mm. 1250 x 2000 mm. 1250 x 2125 mm. 1250 x 2250 mm. Other. Guidance for specification option: A range of sizes are available: consult manufacturer for details. Manufacturer guidanceStandard sizes. |
Performance | |
Fire resistance | |
Integrity | To BS EN 1634-1 E30/ EI30. |
Smoke leakage | To DIN 18095/ EN 1634-3, smoke proof. Guidance for specification option: For solid walls and lightweight construction stud walls. |
Acoustic performance | To DIN EN 20140 acoustic standard rated Rw 42 dB. |
Strength and durability | To EN 1191, C5. |
Thermal | To EN ISO 12567-1, 1.3 W/m²K. Guidance for specification option: Sheet thickness 1.0 mm. To EN ISO 12567-1, 1.4 W/m²K. Guidance for specification option: Sheet thickness 1.5 mm. Manufacturer guidanceWithout glazing. |
Intruder resistance | |
Minimum requirement | Not applicable. To EN 1627, RC4. LPS 1175 Issue 7 security standard to SR3 rating. LPS 1175 Issue 8 security standard to A1 (SR1) rating. LPS 1175 Issue 8 security standard to B3 (SR2) rating. LPS 1175 Issue 8 security standard to C5 (SR3) rating. LPS 1175 Issue 8 security standard to D5 (SR4) rating. LPS 2081 Stealth A rating. LPS 2081 Stealth B rating. |
Application | Manufacturer guidanceInsert requirements. |
Bullet resistance | Not required. To BS EN 1522, Class FB4. |
Frame | |
Material | Steel, 2 mm-thick corner frame. Guidance for specification option: Standard. T90 FSA: 2/ 3mm thick with three-sided seal and bottom sill. With three welded-on wall anchors per side and fire protection strips in the upper part. Steel, 2 mm counter frame. Steel, 2 mm closed frame. Steel, 2 mm single rebate 'block' frame. Guidance for specification option: T60 FSA: German design single rebate 'Block' 2 mm thick, mitred corners at the vertical to head joints. |
Finish | |
Coating | Polyester powder-coated. Guidance for specification option: Door leaf and frame galvanized steel, polyester powder-coated. Stainless steel. |
Colour | RAL. Guidance for specification option: Powder-coated any RAL colour, insert requirements. Stainless steel. |
Door leaf | |
Thickness | 62 mm. |
Core | Mineral wool. |
Panel details | Solid. Vision panel(s). Guidance for specification option: Insert requirements below under Glazing. |
Material | Steel. |
Glazing | |
Type | Rectangular vision panel(s), fire-resistant 37 mm-thick Promaglas. Guidance for specification option: Insert requirements, maximum 741 x 1658 mm. 300 mm-diameter vision panel(s), fire-resistant 37 mm-thick Promaglas. 400 mm-diameter vision panel(s), fire-resistant 37 mm-thick Promaglas. 500 mm-diameter vision panel(s), fire-resistant 37 mm-thick Promaglas. Not required. |
Finish | |
Coating | Polyester powder-coated. Guidance for specification option: Door leaf and frame galvanized steel, polyester powder coated. Stainless steel. Guidance for specification option: Optional. As Frame. |
External colour | RAL. Guidance for specification option: Powder coated any RAL colour, insert requirements. Stainless steel. As Frame. |
Internal colour | RAL. Guidance for specification option: Powder coated any RAL colour, insert requirements. Stainless steel. As External. |
Door accessories | Not requirement. 3D adjustable architectural hinges. Guidance for specification option: 3D adjustable architectural hinges along with various other accessories are available, consult manufacturer for details. |
Hardware | One spring hinge and one construction hinge with ball bearing. Two CO hinges with ball bearing and one TDC. Mortise lock prepared for profile cylinder according to DIN 18250. FP round handle set black (plastic). Guidance for specification option: Handle pivoted on bearing with tumbler(Bb) insert and 1 Bb-key. Handle sets/lever/knob sets. Guidance for specification option: Various options available, consult manufacturer and insert requirement.
Prepared for rose escutcheon. Panic bar. Panic lock. Block lock. Profile cylinder 40.5 + 40. 5 mm. TDC DIN EN 1154 hinge/opposite hinge side. Guidance for specification option:
Electrical door opener. Lock control (bolt contact) integrated. Opening detector (reed contact) integrated. Swing door drive. Design profile-FB. 3D-hinges (with TDC). |
Accessories | Guidance for specification option: Various items of special equipment and control devices are available, consult manufacturer and insert requirements. |
Type | Double skinned. |
Sheet thickness | 1 mm. 1.5 mm. |
Over panels | Required. Guidance for specification option: As drawing. Not required. |
Reinforcement | Unspecified. |
Country of material origin | Germany |
Country of product manufacture | Germany |
Material | Steel Stainless steel |
A1-A3 (production stage) | Embodied carbon as defined in BS EN 15804 |
Normalised unit | |
Declared unit | 53.85 kg CO₂ eq/m² Self-declared |
Recyclability | Manufacturer's standard. Guidance for specification option: Specific parts of steel and stainless steel are recycled, plastics are thermally recycled. Residual fractions are sent to landfill. |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | Manufacturer guidanceInformation available on request; consult manufacturer for details. |
Steel Fire Doorset & Fire Door Selector I60 E120 EN1634-1
Teckentrup Stainless Steel Door & Doorsets for Fire, Security, Smoke and Acoustic applications in architectural settings, clean environments, high stress & chemical sites.pdf
Fire Protection Door T90-1-FSA "Teckentrup 62" (Technical Data)
Fire Protection Door T90-2-FSA "Teckentrup 62" (Technical Data)
Fire Protection Door T30-1-FSA "Teckentrup 62" (Technical Data)
Fire Protection Door T30-2-FSA "Teckentrup 62" (Technical Data)
Fire Protection Door T60-1-FSA "Teckentrup 62" (Technical Data)
Fire Protection Door T60-2-FSA "Teckentrup 62" (Technical Data)
Environmental Product Declaration
EN ISO 9001: 2008 Certificate