Verified by manufacturer 2 months ago
CWCT Certificate
Certificate type
Thermally broken tilt-and-slide door.
Suitable to act as a door in both private and public buildings.
A thermally broken tilt-and-slide door system.
Features and benefits:
Color | Beige Black Blue Bronze Brown |
Finish | Powder-coated Guidance for specification option: Gloss, Matt or Satin finish. Anodized Guidance for specification option: Metallic finish. |
Material | Aluminium |
Shape | Rectangle |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Uniclass | |
CAWS | L20/280 Doors L20/60 Doors |
Configuration | Single leaf, tilt and slide. |
Doorset size | Manufacturer guidanceConsult manufacturer and insert requirements. |
Performance | |
Fire resistance | |
Insulation | Guidance for specification option: Can withstand temperatures in excess of 200°C. |
Frame | |
Material | Extruded aluminium alloy 6060 T4. Extruded aluminium alloy 6060 T5. Extruded aluminium alloy 6060 T6. |
Finish | |
Coating | To BS EN 12206-1, Powder-coated. Guidance for specification option: Gloss, Matt or Satin finish. To BS EN 12206-1, Anodized. Guidance for specification option: Metallic finish. |
Colour | Manufacturer guidanceInsert requirements. |
Door leaf | |
Thickness | Manufacturer guidanceInsert requirements. |
Glazing | |
Type | Guidance for specification option: Doors can accommodate a range of insulating glass units and can be glazed in the factory or on site. |
Finish | |
Coating | Powder coating to BS EN 12206-1. |
External colour | Manufacturer guidanceInsert requirements. |
Internal colour | Manufacturer guidanceInsert requirements. |
Door accessories | Guidance for specification option: Consult Metal Technology Ltd with requirements. |
Glazing method | Factory-fitted. Site glazed. |
Glazing details | Guidance for specification option: Insert requirements. |
Air permeability | To BS 6375-1, 600 Pa. |
Water resistance | To BS 6375-1, 600 Pa. |
Wind resistance | To BS 6375-1, 2400 Pa. |
Contains Red List materials | No |
Country of product manufacture | United Kingdom |
A1-A3 (production stage) | Embodied carbon as defined in BS EN 15804 |
Normalised unit | |
Declared unit | 7.64 kg CO₂ eq/m² Self-declared Lower emissions Guidance for specification option: Aluminium billet options available 1.9kg CO2e/kg Al and 4.0kg CO2e/kg Al Manufacturer guidanceAluminium billet options available 1.9kg CO2e/kg Al and 4.0kg CO2e/kg Al |