Performance:

With suitable glazing, rooflights can contribute to meeting the requirements of Building Regulations for conservation of heat and power. Consult Metal Technology for recommendations and details.

The windows provide Class III weathertightness as defined by BS 6375-1:

  • Static Air Permeability: <1.5m³/hr. at 600 Pa.
  • Static Water Penetration: 0 ml at 600 Pa.
  • Dynamic Water penetration: 0 ml at 600 Pa.
  • Structural performance: 2400 Pa (140mph).
  • Safety Gust Performance: 3600 Pa (210mph).

Fixing:

Lugs and/ or frame anchors used to secure windows to the building structure must accommodate predicted loads and deflection within design tolerances. Generally, fixings must be positioned 150 mm from each corner and each mullion/ transom, and at centres not exceeding 600 mm. Fixing lugs/ straps should be used only where they can be suitably concealed.

Secured by Design:

System 17 rooflight has been tested in line with PAS24 security standards and is certified by a UKAS accredited certification body.

General information
Size

As drawing

As schedule

Material

Extruded aluminium alloy 6060 T4

Extruded aluminium alloy 6060 T5

Extruded aluminium alloy 6060 T6

Uniclass 2015 Framed rooflights (Pr_30_59_72_31)
Specification data
Product Reference

System 17 Rooflight

Size

As drawing

As schedule

Material

Extruded aluminium alloy 6060 T4

Extruded aluminium alloy 6060 T5

Extruded aluminium alloy 6060 T6

Finish -
Internal colour

Insert requirements.

Colour

Insert requirements.

Glazing details

Insert requirements.

Glazing method

Factory fitted

Site glazed

Ironmongery/ Accessories

Consult Metal Technology Ltd with requirements.

Product Options

Finish (as delivered):

Aluminium sections are polyester powder coated to BS EN 12206, with the option of different interior and exterior colours. Consult Metal Technology for availability of colours and to obtain samples.

Glazing:

Dry glazed using proprietary, high performance captive gaskets. All double-glazed units, panels and inserts are supported continuously along all four edges by a structural member and held firmly in position by means of a screw fixed pressure plate with a snap-on face cap. All gasket joints within the frame are bonded and sealed during construction, using a suitable waterproof adhesive to ensure watertight joint at all cruciform connections.