NBS Source
I'm a manufacturer
Compare variants

Superglass Acoustic Partition Roll (APR) - Acoustic Insulation

Verified by manufacturer 28 days ago

Acoustic Partition Roll (APR) - 50 mm

Superglass Insulation Ltd Variant:
Third party certifications:
  • EPD

    EPD

    Certificate type

  • ISO 9001 Quality Management

    Certificate type

  • UK Conformity Assessed (UKCA)

    UK Conformity Assessed (UKCA)

    Certificate type

  • CE Marking

    Certificate type

  • BS EN 13501-1

    BS EN 13501-1

    Certificate type

  • DoP

    DoP

    Certificate type

Superglass Acoustic Partition Roll (APR) is a non-combustible glass mineral wool insulation roll for use in internal walls & floors.

Jump to:
+44 (0)808 1645 134 Website

Application

Superglass Acoustic Partition Roll (APR) is designed to provide thermal and acoustic insulation for the following applications:


  • Internal walls and floors
  • Separating walls and floors
  • Timber and metal stud partitions
  • Drylining system


Description

Superglass Acoustic Partition Roll (APR) is a non-combustible glass mineral wool insulation roll. The roll is supplied at 1200mm, 2x600mm or 3x400mm widths to allow quick and easy installation between common stud/joist spacings, minimising gaps at joints and reducing on-site cutting.


Density:

25mm is manufactured at a nominal density of 18kg/m³.

40mm and 50mm is manufactured at a nominal density of 16kg/m³.


Thermal Conductivity:

25mm has a declared thermal conductivity (lambda (λ) value) of 0.036W/mK.

40mm and 50mm has a declared thermal conductivity (lambda (λ) value) of 0.038W/mK.


Fire Classification:

Deemed non-combustible with a fire classification of Euroclass A1 (the highest possible rating) when tested to BS EN 13501-1 Reaction to Fire.


Vapour Resistivity

The product has a nominal vapour resistivity of 5 MN·s/g·m.


Environmental credentials.

  • Manufactured in accordance with ISO 14001 - Environmental Management Systems (EMS). Certificate number: EMS 646508.
  • Contains no ozone-depleting substances or greenhouse gases. For more information, please refer to the Environmental Product Declaration (EPD).
  • Made from up to 84% recycled glass.
  • Generic BRE Green Guide Rating of A+.


Standards and Approvals.

  • BS EN 13162:2012(+A1:2015) Thermal insulation products for buildings - Factory made mineral wool (MW) products.
  • BS EN 13172: 2012 Thermal insulation products – Evaluation of conformity.
  • BS EN ISO 9001 - Quality Management Systems (QMS). Certificate number: FM 02264.


Certification:

  • UKCA certified to BS EN 13162:2012+A1:2015. Certificate number: 0086 CPR 469699.
  • CE marked to BS EN 13162:2012+A1:2015. Certificate number: 0751-CPR-399.0-01.


General information

Color

Yellow

Material

Glass mineral wool

Mineral wool

Mineral fibre

Shape

Rectangle

Length

11250 mm

6500 mm

Width

1200 mm

600 mm

Height

25 mm

50 mm

Uniclass

Pr_25_57_06_53 Mineral wool insulationPrimary

Pr_25_57_06/310 Insulation products generally

Pr_25_57_06_34 Glass fibre insulation

CAWS

J31/23 Mineral wool insulation

K10/115 Metal stud partition system

K10/125 Metal stud partition system

K10/145 Wall lining system (metal studs)

K10/175 Wall lining system (metal furrings)

K10/215 Suspended ceiling system

K10/165 Wall lining system (metal framing)

K10/155 Wall lining system (metal studs)

K10/220 Proprietary suspended ceiling system

K11/235 Oriented strand board floating floor

K11/225 Particleboard floating floor

K11/245 Cement bonded particleboard floating floor

K11/215 Plywood floating floor

K11/115 Battened plywood floating floor

K11/135 Battened oriented strand board floating floor

K11/125 Battened particleboard floating floor

K11/275 Acoustic separating floor system

K13/160 Proprietary

K13/170 Acoustic panel lining

K20/150 Battened timber board floating floor

K21/130 Battened wood floating floor

K21/120 Battened wood flooring

K21/140 Battened wood laminate flooring

K21/145 Composite laminate flooring

K45/425 Insulation

P10/45 Insulation laid between floor joists

P10/50 Insulation supported between joists

P10/40 Insulation fitted betweenor to the face ofstuds

K10/35 Wall lining system (metal framing)

K10/50 Suspended ceiling system on metal framing

K45/50 Insulation

P10/190 Insulation fitted between studs

P10/240 Insulation fitted between floor joists

K10/30 Metal stud

K11/25 Particleboard floating floor

K10/85 mineral wool insulation

K20/20 Battened timber board floating floor

K21/20 Composite laminated flooring

K40/55 Insulation

B15/120 Timber-framed

B15/110 Timber-framed

Product range

Internal Partition Insulation
Glass Mineral Wool Insulation
Internal Floor Insulation

Specification data - Mineral wool insulation

Standard

To BS EN 13162.

Guidance for specification option:

Manufactured in accordance with:

  • BS EN 13162:2012(+A1:2015) thermal insulation products for buildings factory made mineral wool (MW) products.
  • BS EN 13172:2012 thermal insulation products evaluation of conformity.
  • BS EN ISO 9001:2015 quality management systems (QMS).

Form

Glass mineral wool roll.

Thickness (minimum)

50 mm.

Width (nominal)

1200 mm.

600 mm.

Guidance for specification option:

Supplied as 2 x 600 mm sections.

Fire performance

Reaction to fire classification of A1, as defined in BS EN 13501-1.

Guidance for specification option:

All Superglass products are deemed non-combustible and have a fire classification of A1 when tested to BS EN 13501-1 reaction to fire.

Recycled content

Up to 84%.

Guidance for specification option:

All Superglass products are deemed non-combustible and have a fire classification of A1 when tested to BS EN 13501-1 reaction to fire.

Green guide rating

A+.

Length

6500 mm.

R-Value

1.30 m²K/W.

Sustainability data

Contains Red List materials

No

Country of material origin

United Kingdom

Country of product manufacture

United Kingdom

Material

Glass mineral wool

Mineral wool

Mineral fibre

Manufacturing plant location

Embodied carbon

A1-A3 (production stage) as defined in BS EN 15804

1.35 kg CO₂ eq/kg

Manufacturer guidance

Please see product EPD.

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

84 %

Guidance for specification option:

All Superglass products are deemed non-combustible and have a fire classification of A1 when tested to BS EN 13501-1 reaction to fire.

Expected Life

Lifetime

Third party certifications

BIM objects

Platform Compatible Version
Revit
-

1

Third party certifications

EPD

EPD

Environmental Product Declaration (EPD) – Cured Glass Mineral Wool Insulation

ISO 9001 Quality Management

ISO 9001 Quality Management

Quality Management System ISO 9001:2015

UK Conformity Assessed (UKCA)

UK Conformity Assessed (UKCA)

UKCA Certificate - Cured Glass Mineral Wool Insulation

CE Marking

CE Marking

CE Certificate - Cured Glass Mineral Wool Insulation

BS EN 13501-1

BS EN 13501-1

Euroclass A1 Reaction to Fire Classification

DoP

DoP

Declaration of Performance (DoP) - 25mm Superglass Acoustic Partition (APR) - UKCA

DoP

DoP

Declaration of Performance (DoP) - 50mm Superglass Acoustic Partition (APR) - UKCA

Literature

Superglass Acoustic Partition Roll (APR) - Datasheet

Superglass Acoustic Partition Roll (APR) - Datasheet

Insulation Solutions Guide

Insulation Solutions Guide