Verified by manufacturer 2 days ago
Polymer modified bitumen membrane green roofing system.
Suitable for protective roof gardens, sunken works and gravel covered roofs. It is used in all waterproofing systems in contact with the ground or where there is a risk of the system being attached by roots.
A root resistant waterproofing membrane, The antiroot properties are obtained by adding phenoxifatty acid ester, a specific antiroot agent, to the polymer-bitumen compound. Once applied, it forms a continuous barrier against roots.
As it does not contain film or double-reinforced foils, defend antiroot polyester is more flexible and malleable
during application. The additive has been developed specifically as a root inhibitor, for both hot-laid bitumen
and for torch-laid bitumen membranes, The product comes from thirty years of German experience in the
waterproofing industry.
Manufactured from distilled and selected bitumen for industrial use containing high quantity of
elsatoplatomeric polymers such as to obtain a 'phase inversion' alloy. The continuous phase of this alloy
consists of the polymer in which the bitumen is dispersed, where the characteristics are determined by the
polymer matrix and not by the bitumen, even if it is the largest ingredient. The performance of bitumen is
therefore increased, durability and resistance to high and low temperatures are improved, thus maintaining
the bitumen’s already excellent qualities of adhesion and waterproofing.
The reinforcement of the membrane consists of single strand spunbound non-woven polyester fabric,
with high basic weight (grammage). This fabric is isotopic, rot-proof, thermally-fixed and boasts: high
mechanical resistance, considerable ultimate elongation, excellent resistance to puncturing and laceration.
The membrane has both faces coated with Flamina, the hot-melt film, which stops the rolls of material from
sticking together. The reinforcement and the waterproofing mass are resistant to chemical effects of humic acids and fertilizers.
Features and benefits:
System Includes:
Color | Grey |
Finish | Mineral |
Material | Bitumen |
Shape | Rectangle |
Length | 10000 mm |
Width | 1000 mm |
Height | 0.2 mm Guidance for specification option: Thickness |
Uniclass | |
CAWS | J41/110 Built-up reinforced bitumen membrane warm deck roof covering J41/10 Reinforced bitumen membrane warm deck roof covering |
Preparation | |
Horizontal work | Strataprime.Guidance for specification option: ICB STRATAPRIME is a black priming solution designed to deeply penetrate and seal porous surfaces to provide a base for bituminous waterproofing and flashing systems. It contains a wetting agent to enable it to be applied to ‘damp’ as well as dry surfaces. |
Skirtings and vertical work | Strataprime.Guidance for specification option: ICB STRATAPRIME is a black priming solution designed to deeply penetrate and seal porous surfaces to provide a base for bituminous waterproofing and flashing systems. It contains a wetting agent to enable it to be applied to ‘damp’ as well as dry surfaces. |
Waterproof covering | |
First layer | |
Type | Stratabase SBS.Guidance for specification option: STRATABASE-SBS consist of a special compound based on distilled bitumen modified with selected elastomers and reinforced with a non-woven spunbond polyester reinforcement, which offers good characteristics of mechanical resistance, ultimate elongation and dimensional stability. Manufacturer guidanceRoll size: 1 x 15 m. Thickness: 2 mm. |
Attachment | Torch-applied. |
Top layer | |
Type | Stratagreen.Manufacturer guidanceRoll size: 1 x 10 m. Thickness: 0.2 mm. |
Attachment | Torch-applied. |
Detail work | |
Welted drips | Contractor to form suitably sized welted drip on site. |
System accessories | Ryno GRP Pultruded glass fibre reinforced polyester roof edge trim.Guidance for specification option: Installation: RynoTrim is fixed over the first layer of a built-up roofing system. The trim should be fixed at maximum 300 mm centres, using suitable fixings. Welted Drip.Guidance for specification option: Contractor to form suitably sized welted drip on site. Lead Flashing.Guidance for specification option: Created on site using suitable code lead and following the relevant codes of practice. FPA Profile.Guidance for specification option: Mechanically fixed to the wall 150 mm min. above finished roof level. Fixed at 200 mm centres using ICB approved fixings. Roof Vent.Guidance for specification option: Manufacturer: RYNO – Product of ICB (Waterproofing) Ltd. - Product reference: Ryno Breather Vent Diameter: 75 mm. Ryno Flat Flange Outlets Diameter: 50–150 mmGuidance for specification option: Manufacturer: RYNO – Product of ICB (Waterproofing) Ltd. - Product reference: Ryno Flat Flange Outlets Diameter: 50mm-150mm Ryno Horizontal Outlets Diameter: 65 / 100 mm.WalkwayGuidance for specification option: Product reference: Stratawalk Colour: Red. |
Country of product manufacture | Italy |
Material | Bitumen |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | 0.05 kg CO₂ eq/unit Self declared |