PREFALZ aluminium standing seam is available in 20 different colours, including a range of P.10 finishes. It is lightweight, malleable, corrosion resistant, rust proof and A1 non combustible.
500 and 650 mm width coils are applicable for use in standing seam roofing.
1000 mm coil widths are suitable for use as flashing strips.
Aluminium standing seam roof system.
Prefalz® is highly malleable and therefore easy to shape. This results in countless individual design possibilities.
Using Prefalz® includes all the advantages of aluminium, combined with a material guarantee of 40-years.
Features and benefits:
PREFA PREFALZ® – COLOUR RANGE & NEAREST RAL
01. P.10 BROWN
Nearest RAL 7013
02. P.10 ANTHRACITE
Nearest RAL 7016
03. P.10 BLACK
Nearest RAL 9005
04. P.10 BRICK RED
Nearest RAL 8004
05. P.10 OXIDE RED
Nearest RAL 3009
06.P.10 MOSS GREEN
Nearest RAL 6005
07.P.10 LIGHT GREY
Nearest RAL 7005
08. P.10 ZINC GREY
Nearest RAL 7030
10. P.10 PREFA WHITE
Nearest RAL 9002
11. P.10 NUT BROWN
Nearest RAL 8019
12. METALLIC SILVER
Nearest RAL 9006
13.PLAIN ALUMINIUM
-
17. P.10 PURE WHITE
Nearest RAL 9010
19.P.10 DARK GREY
Nearest RAL 7043
23. BLACK GREY
Nearest RAL 7022
43. P.10 STONE GREY
Nearest RAL 7031
45. BRONZE
Nearest RAL 7048
46.P.10 PATINA GREEN
Nearest RAL 6027
47. PATINA GREY
Nearest RAL 7042
Color | Black Brown Bronze Green Grey |
Finish | Coated |
Material | Aluminium |
Shape | Other |
Length | Bespoke |
Width | 0.7 mm |
Height | 500 mm 650 mm |
Warranty description | 40 year Guidance for specification option: 40 year for material, up to 40 year for colour. |
Uniclass | |
CAWS | H72/110 Aluminium sheet fully supported roof covering |
Membrane | Vapour permeable sheets in accordance with BS EN 13859-1. |
Insulation | Guidance for specification option: Please insert requirement. NOTE: An aluminium standing seam roof does not have any specific requirement with regard to the insulation, unless it is used as the substrate for the standing seam in a warm roof build-up. In this instance, the insulation must be dense in quality and supportive of foot traffic without denting, with a minimum compression strength of 50 kpa (0.5 kg/cm²) at a maximum of 10% deformation and remain dimensionally stable at 100°C. |
Substrate | 24 mm open gap softwood boards.Guidance for specification option: 24 mm open gap softwood boards, according to EN 12775-2. In widths of 100 mm to 125 mm and laid with 3-5 mm gaps between the boards parallel to the eaves, with fastener heads driven just below surface. 50 mm minimum vented cavity, 25 mm open air inlet at the eave and 25 mm open air outlet at the ridge. 50 mm cavity created with a batten. Standing seam fixings, and positioning, as per PREFA installation instructions and FTMRC Guidelines. Pitches from 3° to the vertical.
System build-up:
18 mm WBP external grade plywood.Guidance for specification option: 18 mm WBP external grade plywood - EN 314 bond class 2 and EN 636-2 timber performance. A 50 mm minimum vented cavity must be created under the plywood using battens. The cavity must have a minimum 25 mm open air inlet at the eaves, and a minimum 25 mm open air out let at the ridge. Standing seam fixings, and positioning, as per PREFA installation instructions and FTMRC Guidelines. Pitches from 3° to the vertical.
System build-up:
Ventilated galvanized steel metal deck.Guidance for specification option: 0.9 mm thickness. To give a minimum clip pull-out value of 400 N, installed 'façade side outwards' to give maximum support to the standing seam panels, parallel to eaves, all ends supported. A 50 mm minimum vented cavity must be created under metal deck, using a bracket and rail system. The cavity must have a minimum 25 mm open air inlet at the eave and a minimum 25 mm open air out let at the ridge. Standing seam fixings, and positioning, as per PREFA installation instructions and FTMRC Guidelines Pitches from 3° to the vertical. |
Cavity barriers | Guidance for specification option: To architects specification. Insert accordingly. |
Sheet underlay | |
Material | Aluminium alloy. |
Eave details | |
Form | Guidance for specification option: To PREFA installation guidelines and detailing. |
Verge details | |
Form | Guidance for specification option: To PREFA installation guidelines and detailing. |
Material | Aluminium alloy. |
Fixings | |
Joints | PREFA preformed fixed and sliding clips.Guidance for specification option: According to project requirements. |
Ridge and hip details | |
Form | Guidance for specification option: To PREFA installation guidelines and detailing. |
Abutments | |
Form | Guidance for specification option: To PREFA installation guidelines and detailing. |
System accessories | Guidance for specification option: An extensive range of accessories is available; consult literature for details and insert requirements. |
Colour/ Finish | 01 Brown P.10. Guidance for specification option: Similar to RAL 7013. 02 Anthracite P.10. Guidance for specification option: Similar to RAL 7016. 03 Black P.10. Guidance for specification option: Similar to RAL 9005. 04 Brick Red P.10. Guidance for specification option: Similar to RAL 8004 05 Oxide Red P.10. Guidance for specification option: Similar to RAL 3009. |
Width | 500 mm. 650 mm. |
Thickness | 0.7 mm. |
Roof pitch | Guidance for specification option: The manufacturer recommends a minimum substructure roof pitch of >7° (13%). Roof pitch from 3° is possible. From 3–7° it is required to seal the seams (using PREFA Sealing Gel). The position of clips will be according to roof pitch – consult PREFA planning guide. |
Weight | 1.89 kg/m². Guidance for specification option: Average consumption of approximately 2.3 kg/m² (500 mm-wide coils) or 2.2 kg/m² (650 mm-wide coils). |
Installation | Guidance for specification option: On fully boarded substrate (thickness in accordance with national guidelines or regulations; PREFA recommends 24 mm). A suitable separation layer is required. Observe national standards and specialist guidelines (such as the FTMRC Guide to Good Practice in Metal Roofing). |
FireRating | A1. Guidance for specification option: Non-combustible. |
Surface finish | Stucco. Guidance for specification option: As standard. Smooth. Guidance for specification option: Available on request. |
Rear panel | Protective paint. |
Third-party certification | QA Certificate. |
Contains Red List materials | No |
Country of material origin | Austria |
Country of product manufacture | Austria |
Material | Aluminium |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | 6.39 kg CO₂ eq/kg Manufacturer guidanceEPD available upon request |
Recyclability | 100 Manufacturer guidanceFully Recycable |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 87 % Manufacturer guidanceInformation available upon request |
EPD
Environmental Performance Declaration
BBA Agrément Certificate
BBA Cert for Non-P.10 Coated PREFALZ
BBA Agrément Certificate
BBA Certificate for P.10 Coated PREFALZ
QA Certificate
IQNet-certification-ISO-9001-2015
ISO 9001 Quality Management
ISO -9001:2015
Fire Safety Certification
PREFA Fire Classification Report