Verified by manufacturer 2 months ago
70-S-63(50)
BES 6001
Certificate type
BSI Kitemark
Certificate type
EPD
Certificate type
ISO 14001 Environmental Management Systems
Certificate type
ISO 9001 Quality Management
Certificate type
UK Conformity Assessed (UKCA)
Certificate type
An economical friction-fit system to assemble frames for strong, compact and lightweight non-load‑bearing partition.
Sectors:
An economical friction-fit system to assemble frames for strong, compact, lightweight non-load‑bearing partitions, Speedline Partitioning Systems are suitable for use in domestic and commercial situations.
Features and benefits:
Structural performance:
Fire performance:
Acoustic performance:
Installing framing for partitions:
Length | Bespoke |
Width | 102 mm 124 mm 127 mm 132 mm 149 mm |
Height | Bespoke |
Uniclass | |
CAWS | K10/30 Metal stud K10/125 Metal stud partition system |
Product range |
Framing | Speedline 'C' Stud, 70 mm. |
Insulation | Acoustic partition roll, 50 mm. |
Linings | |
Outer layers | Siniat GTEC Universal/Megadeco Board, 15 mm. |
Fasteners | Speedline Drywall Screws. |
Joint treatment | Speedline Drywall Fibreglass Tape.Speedline Ready Mix Joint Compound.Speedline Putty Pads.Speedline Corner Bead Tape. |
System accessories | Speedline Fire Rated Acoustic Sealant.Speedline PB24 Partition Brace.Speedline FS24 Flat Bracing Strip.Speedline Service Support Plate.Speedline Putty Pads. |
Fire resistance | To BS 476:1987:Part 22, 60/ 60 minutes (Integrity/ Insulation). |
Partition height | Guidance for specification option: Insert requirement based on centres specified.
Calculated based on a limiting deflection of L/240 at 200 Pascals. |
Nominal thickness | 102 mm. Guidance for specification option: Optimum system thickness. Note that if a greater partition thickness is required, this may improve the sound reduction index (Rw) - consult manufacturer for details. |
Calculated weighted sound reduction index (Rw) | 47 Rw dB. Guidance for specification option: Based on the nominal system thickness. |
StrengthGrade | Severe duty. |
Centres | 600 mm. Guidance for specification option: Standard. 400 mm. Guidance for specification option: Allows for greater maximum partition heights. 300 mm. Guidance for specification option: Allows for greater maximum partition heights. |
Head/ Floor channel | Speedline Standard Track. Guidance for specification option: Used for partition heights under 4 m. Available in 50, 52, 62 or 72 mm wide. 25 mm flange. Speedline 32 mm Leg Track. Guidance for specification option: Used for partition heights under 4 m. Available in 52, 62, 72, 94 or 148 mm wide. 32 mm flange. Speedline Deep Track. Guidance for specification option: Used for partition heights between 4m and 8m. Can be used as a head track where a deflection head of up to 30 mm is needed. Available in 52, 62, 72, 94 or 148 mm wide. 50 mm flange. Speedline Extra Deep Track. Guidance for specification option: Used for partition heights between 8m and 10.2 m. Can be used as a head track where a deflection head of up to 45mm is needed. Available in 72, 94 or 148 mm wide. 70 mm flange. |
BES 6001
BES 6001 Responsible Sourcing of Construction Products
BSI Kitemark
BIM Level 2 Kitemark - For Design and Construction Phase
BSI Kitemark
BSI Kitemark™ for BIM Objects
EPD
Environmental Product Declaration EPD - Drylining
ISO 14001 Environmental Management Systems
ISO 14001:2015 Environmental Management System
ISO 9001 Quality Management
ISO 9001:2015 Quality Management System
UK Conformity Assessed (UKCA)
UKCA Declarations of Performance - Drylining