Verified by manufacturer 3 months ago
50-K-58(25)
BSI Kitemark
Certificate type
EPD
Certificate type
ISO 9001 Quality Management
Certificate type
UK Conformity Assessed (UKCA)
Certificate type
An economical friction-fit system to assemble frames for strong, compact and lightweight non load‑bearing partition.
Sectors:
An economical friction-fit system to assemble frames for strong, compact, lightweight-non load‑bearing partitions, Speedline Partitioning Systems are suitable for use in domestic and commercial situations.
Features and benefits:
Structural performance:
Fire performance:
Acoustic performance:
Installing framing for partitions:
Length | Bespoke |
Width | 77 mm 82 mm 97 mm 102 mm 112 mm |
Height | Bespoke |
Uniclass | |
CAWS | K10/30 Metal stud K10/125 Metal stud partition system |
Product range |
Framing | Speedline 'C' Stud, 50 mm. |
Insulation | Acoustic partition roll, 25 mm. |
Linings | |
Inner layers | Knauf Wallboard, 15 mm. |
Outer layers | Knauf Wallboard, 15 mm. |
Fasteners | Speedline Drywall Screws. |
Joint treatment | Speedline Drywall Fibreglass Tape.Speedline Ready Mix Joint Compound.Speedline Corner Bead Tape. |
System accessories | Speedline Fire Rated Acoustic Sealant.Speedline PB24 Partition Brace.Speedline FS24 Flat Bracing Strip.Speedline Service Support Plate.Speedline Putty Pads. |
Fire resistance | To BS 476:1987:Part 22, 60/ 60 minutes (Integrity/ Insulation). |
Partition height | Guidance for specification option: Insert requirement based on centres specified.
Calculated based on a limiting deflection of L/240 at 200 Pascals. |
Nominal thickness | 112 mm. Manufacturer guidanceOptimum system thickness. Note that if a greater partition thickness is required, this may improve the sound reduction index (Rw) - consult manufacturer for details. |
Calculated weighted sound reduction index (Rw) | 47 Rw dB. Guidance for specification option: Based on the nominal system thickness. |
StrengthGrade | Severe duty. |
Centres | 600 mm. Guidance for specification option: Allows for greater maximum partition heights. 400 mm. Guidance for specification option: Allows for greater maximum partition heights. 300 mm. Guidance for specification option: Standard. |
Head/ Floor channel | Speedline Standard Track. Guidance for specification option: Used for partition heights under 4 m. Available in 50, 52, 62 or 72 mm wide. 25 mm flange. Speedline 32 mm Leg Track. Guidance for specification option: Used for partition heights under 4 m. Available in 52, 62, 72, 94 or 148 mm wide. 32 mm flange. Speedline Deep Track. Guidance for specification option: Used for partition heights between 4m and 8m. Can be used as a head track where a deflection head of up to 30 mm is needed. Available in 52, 62, 72, 94 or 148 mm wide. 50 mm flange. Speedline Extra Deep Track. Guidance for specification option: Used for partition heights between 8m and 10.2 m. Can be used as a head track where a deflection head of up to 45mm is needed. Available in 72, 94 or 148 mm wide. 70 mm flange. |