AS92-K-160(50)

Metsec (voestalpine Metsec) Variant:
Third party certifications:
  • BSI Kitemark

    BSI Kitemark

    Certificate type

  • EPD

    EPD

    Certificate type

  • ISO 9001 Quality Management

    Certificate type

  • UK Conformity Assessed (UKCA)

    UK Conformity Assessed (UKCA)

    Certificate type

A cost-effective way to achieve improved acoustic performance in both domestic and commercial situations.

Jump to:
+44 (0) 121 601 6000 Website

Application

Sectors:

  • Residential.
  • Offices.
  • Healthcare.
  • Education.
  • Commercial.
  • Retail.
  • RMI.
  • Student accommodation.

Description

A cost-effective way to achieve improved acoustic performance in both domestic and commercial situations, our Acoustic Stud has built in discontinuity which results in improved sound insulation.

 

Acoustic Stud is designed to offer better sound insulation in the key speech frequency bands (250 to 1000 Hz) whilst maintaining structural strength and integrity. This enables slimmer partitions to be constructed, maximizing floor space but still satisfying high acoustic requirements.


Features and benefits:

  • Extremely cost-effective.
  • Ideal for domestic and commercial use.
  • Reduced installation time.
  • Slimmer partitions maximize floor space.
  • Quieter living spaces.
  • Greater sound insulating performance.
  • Reduces the transfer of common noise.
  • Fire: 30–120 minutes.
  • Acoustic: 40–63 Rw dB.
  • Duty Rating Medium, Heavy and Severe available.

Structural performance:

  • Strength grade to BS 5234-2:1992 Annexes A-F.

Fire performance:

  • Fire resistance to BS 476:1987:Part 22.

Acoustic performance:

  • Calculated weighted sound reduction index (Rw) to BS EN ISO 10140-2: 2010.

Installing framing for partitions:

  • Partition height (maximum) calculated based on a limiting deflection of L/240 at 200 Pascals.

General information

Length

Bespoke

Width

102 mm

124 mm

132 mm

Height

Bespoke

Uniclass

Ss_25_10_30_35 Gypsum board partition systemsPrimary

CAWS

K10/30 Metal stud

K10/125 Metal stud partition system

Product range

Drylining / Single Frame Partitions - Acoustic Stud

Specification data - Gypsum board partition systems

Framing

Speedline Acoustic 'C' Stud, 92 mm.

Insulation

Acoustic partition roll, 50 mm.

Linings

-

Inner layers

Knauf Soundshield Plus, 15 mm.

Outer layers

Knauf Soundshield Plus, 15 mm.

Fasteners

Speedline Drywall Screws.

Joint treatment

Speedline Drywall Fibreglass Tape.

Speedline Ready Mix Joint Compound.

Speedline Corner Bead Tape.

System accessories

Speedline Fire Rated Acoustic Sealant.

Speedline PB24 Partition Brace.

Speedline FS24 Flat Bracing Strip.

Speedline Service Support Plate.

Speedline Putty Pads.

Fire resistance

To BS 476:1987:Part 22, 120/ 120 minutes (Integrity/ Insulation).

Partition height

Guidance for specification option:

Insert requirement based on centres specified.

  • 600 mm centres: maximum 5900 mm.
  • 400 mm centres: maximum 6500 mm.
  • 300 mm centres: maximum 6700 mm.

Calculated based on a limiting deflection of L/240 at 200 Pascals.

NominalThickness

132 mm.

Guidance for specification option:

Optimum system thickness.

Note that if a greater partition thickness is required, this may improve the sound reduction index (Rw) - consult manufacturer for details.

Calculated weighted sound reduction index (Rw)

57 Rw dB (-6).

Guidance for specification option:

Based on the nominal system thickness.

Centres

600 mm.

Guidance for specification option:

Standard.

400 mm.

Guidance for specification option:

Allows for greater maximum partition heights.

300 mm.

Guidance for specification option:

Allows for greater maximum partition heights.

StrengthGrade

Severe duty.

Head/ Floor channel

Speedline Standard Track.

Guidance for specification option:

Used for partition heights under 4 m.

Available in 50, 52, 62 or 72 mm wide.

25 mm flange.

Speedline 32 mm Leg Track.

Guidance for specification option:

Used for partition heights under 4 m.

Available in 52, 62, 72, 94 or 148 mm wide.

32 mm flange.

Speedline Deep Track.

Guidance for specification option:

Used for partition heights between 4m and 8m.

Can be used as a head track where a deflection head of up to 30 mm is needed.

Available in 52, 62, 72, 94 or 148 mm wide.

50 mm flange.

Speedline Extra Deep Track.

Guidance for specification option:

Used for partition heights between 8m and 10.2 m.

Can be used as a head track where a deflection head of up to 45mm is needed.

Available in 72, 94 or 148 mm wide.

70 mm flange.

Sustainability data

Third party certifications

Third party certifications

BSI Kitemark

BSI Kitemark

BIM Level 2 Kitemark - For Design and Construction Phase

BSI Kitemark

BSI Kitemark

BSI Kitemark™ for BIM Objects

EPD

EPD

Environmental Product Declaration EPD - Drylining

ISO 9001 Quality Management

ISO 9001 Quality Management

ISO 9001:2015 Quality Management System

UK Conformity Assessed (UKCA)

UK Conformity Assessed (UKCA)

UKCA Declarations of Performance - Drylining

Literature

SPEEDLINE Fixings and Finishing Solutions

SPEEDLINE Fixings and Finishing Solutions

SPEEDLINE Partitioning Systems

SPEEDLINE Partitioning Systems

Product Data Sheet - Drylining

Product Data Sheet - Drylining