Spacetherm - Aerogel insulation blanket.

Verified by manufacturer 6 months ago

Spacetherm

A Proctor Group Ltd Variant:

Aerogel Insulation blanket, optionally laminated to other board materials.

Jump to:
BOS
+44 (0)1250 872261 Website

Application

Suitable for a variety of purposes as general purpose insulation blanket. Also available laminated to a variety of facing boards (e.g. plasterboard, magnesium oxide, plywood) or as encapsulated, self-adhesive cold bridge strips.

Description

Spacetherm is fibrous blanket impregnated with silica aerogel, which can be laminated to a selection of plasterboard, MgO and plywood materials. It can also be supplied on its own in sheet form and is suitable for use internally where low U-values are required but space is limited.


Spacetherm A1 is a glass fibre blanket impregnated with silica aerogel producing a highly thermally efficient insulation which surpasses most insulations, mineral and rigid. Spacetherm A1 Blanket can be installed in layers, using mechanical fixings such as stickpins, to achieve required thermal performance or overall thickness. As it is A1-Rated, it is considered incombustible and can be used where mineral wool may be too great a thickness to employ.


Features and benefits:

  • Ultra low thermal conductivity of 0.015 W/mK (Standard)
  • A1-Rated Material thermal conductivity 0.0195 W/mK.
  • Available cut to any size or shape - contact A Proctor Group Ltd for information.
  • Available bonded to multiple finishing boards.
  • Maximum thermal performance in limited space.
  • 50 year continued thermal performance.
  • Hydrophobic nature resists water absorption.

General information

Material

Fibre-reinforced

Guidance for specification option:

Fibre-reinforced silica gel.

Silica

Shape

Rectangle

Length

Bespoke

2400 mm

Width

Bespoke

1200 mm

Height

Bespoke

10 mm

Uniclass

Pr_25_57_06_02 Aerogel blanket insulationPrimary

CAWS

K11/795 Wall lining on metal framing

K10/45 Wall lining system (adhesive)

K10/41 Wall lining system (metal furrings)

K10/415 Gypsum plasterboard

K10/35 Wall lining system (metal framing)

K10/30 Metal stud

K10/275 Encasement on timber framing

K10/255 Encasement system (metal framing)

K10/245 Ceiling lining on timber

K10/220 Proprietary suspended ceiling system

K10/205 Lining on timber

K10/185 Wall lining system (adhesive)

K10/175 Wall lining system (metal furrings)

K10/165 Wall lining system (metal framing)

K10/15 Lining on timber

K10/155 Wall lining system (metal studs)

K10/125 Metal stud partition system

Specification data - Aerogel blanket insulation

Thermal conductivity (maximum)

0.015 W/mK when tested to EN 12667.

Thickness

5 mm.

10 mm.

Manufacturer guidance

Thickness of insulation to be 5 mm, 10 mm or multiples thereof, bonded by APG to achieve desired thermal performance or overall thickness.

Density

150 kg/m³.

Fire performance

Class C - s1, d0 when tested to EN 13501.

Dimensional stability

Dimensional stability: length, width and thickness all to be no less than 1% when tested to EN 1604 48h at 70°C.

Water vapour permeability

µ = 5.0 when tested to EN 12086.

CompressiveStrength

8psi (55kPa) @ 10% Deflection

BIM objects

BOS

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.

Find out more about the NBS BIM Object Standard.

Platform Compatible Version
Revit
-

1

IFC
-

1

Literature

Spacetherm - Building & Construction Brochure

Spacetherm - Building & Construction Brochure

Spacetherm - Custom Applications

Spacetherm - Custom Applications

Spacetherm Wall Liner Brochure

Spacetherm Wall Liner Brochure

Proctor Group HAMM Principles Brochure

Proctor Group HAMM Principles Brochure

Spacetherm FAQ Document

Spacetherm FAQ Document

Proctor Group Modular & Offsite Solutions

Proctor Group Modular & Offsite Solutions

Proctor High Rise and Façade Systems

Proctor High Rise and Façade Systems

Proctor Passive House Systems

Proctor Passive House Systems

Wraptherm Installation Guide

Wraptherm Installation Guide

Spacetherm CBS Installation Guide

Spacetherm CBS Installation Guide

Spacetherm Wallboard Installation Guide

Spacetherm Wallboard Installation Guide

Spacetherm Multi Installation Guide - Timber Frame/Battens

Spacetherm Multi Installation Guide - Timber Frame/Battens

Spacetherm Multi Installation Guide - Direct to Masonry

Spacetherm Multi Installation Guide - Direct to Masonry

Spacetherm Directfix Installation Guide

Spacetherm Directfix Installation Guide

Spacetherm Window Reveal Board Installation Guide

Spacetherm Window Reveal Board Installation Guide

Spacetherm Multi Installation Guide - Floors

Spacetherm Multi Installation Guide - Floors

Spacetherm Wall Liner Installation Guide

Spacetherm Wall Liner Installation Guide

Spacetherm Installation Essentials

Spacetherm Installation Essentials

Spacetherm MgO Facing Information

Spacetherm MgO Facing Information

Spacetherm Wall Liner Datasheet

Spacetherm Wall Liner Datasheet

Spacetherm Wraptherm Datasheet

Spacetherm Wraptherm Datasheet

Spacetherm Wallboard Datasheet

Spacetherm Wallboard Datasheet

Spacetherm Multi Datasheet - Walls

Spacetherm Multi Datasheet - Walls

Spacetherm Multi Datasheet - Floors

Spacetherm Multi Datasheet - Floors

Spacetherm Directfix Datasheet

Spacetherm Directfix Datasheet

Spacetherm Cold Bridge Strip Datasheet

Spacetherm Cold Bridge Strip Datasheet

Case studies

Spacetherm Multi - Bath

Spacetherm Multi - Bath

Spacetherm WL - Paris