Verified by manufacturer 17 hours ago
Soleal Next PZ75 - Entrance Door
Secured By Design
Certificate type
Cradle to Cradle Certified
Certificate type
EN 1627-1630 RC2
Certificate type
BM Trada
Certificate type
PAS 24
Certificate type
An aluminium door that provides maximum light and has been created to be dismantled at the end of its use phase. SOLEAL Next is designed with a circular economy in mind.
Suitable for all applications, including: commercial, residential, education and hospitality.
The SOLEAL Next door has been created to offer a range of solutions to cover the different needs for safety, comfort and building management. It is available in many applications, including, stand-alone or with fixed field, glazed or with overlapping panel, push pull, façade integrated, hinged, and low or barrier free threshold.
SOLEAL Next offers effective thermal, acoustic and weather performance, all complying with the highest international standards. It is also the greener option for projects, created with a circular economy in mind. It is made with 75% recycled materials and is 100% recyclable at the end of its life.
SOLEAL Next combines aesthetic design with a large choice of colours and accessories, as well as concealed elements and hardware to bring elegance and modernity for new or renovated building projects.
Features and benefits:
Sustainability Information:
Finish | Powder-coated Anodized |
Material | Aluminium Polyamide Acrylonitrile butadiene styrene (ABS) |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Uniclass | |
CAWS | L20/55 Doorsets L20/480 Doorsets |
Product range |
Manufacturer | Technal. |
Standard | External non-fire-rated aluminium alloy doorset to BS 4873 and UKCA/ UKNI/ CE marked in accordance with BS EN 14351-1. |
Configuration | Single-leaf, single-action. Double-leaf, single-action. Leaf and part-leaf, single-action. |
Doorset size | Manufacturer guidanceMaximum size 1400 x 3000 mm (W x H). Insert requirements or refer to a drawing or schedule. |
Performance | |
Acoustic performance | Up to a maximum Rw = 43 dB. Guidance for specification option: With double glazing 50 mm: 88.2 Si/ 20/ 66.2 Si. Actual performance dependant of glazing infill performance - to be determined, refer to acoustic report. |
Strength and durability | To BS EN 1191:2012, Class 7. Guidance for specification option: 500 000 cycles. Class 4 in accordance with EN 12046-1. |
Thermal | 1.35 W/m²K. Guidance for specification option: With 1.0 W/m²K DGU. 1.2 W/m²K. Guidance for specification option: With 0.8 W/m²K TGU. |
Intruder resistance | |
Minimum requirement | To EN 1627, RC2. To EN 1627, RC3. To PAS 24. Secured by Design certification. |
Conformity | Certification by accredited third-party certification body. |
Frame | |
Material | Aluminium. Guidance for specification option: Hydro CIRCAL® aluminium.
|
Threshold | Approved Doc M approved. |
Perimeter seals or inserts | EPDM weatherseal, ≤ 250 mm width. Guidance for specification option: In accordance with CWCT/ SFE 'Technical Guidance for interpretation in relation to external walls and specified attachments of Relevant Buildings in England issue 2, July 2023'. |
Finish | |
Coating | Powder coating to BS EN 12206-1. Guidance for specification option: Any special warranties or guarantees (such as marine or industrial/ chlorine) to be issued directly by the powder supplier and agreed prior to material order. Anodizing to BS 3987. Manufacturer guidanceAll finishing to be undertaken by Hydro Building Systems prior to delivery to the manufacturer. |
Texture | Gloss. Matt. Satin. |
Colour | Standard Technal finish. Manufacturer guidanceStandard Technal finish (RAL, gloss level and classification TBC) from standard Technal range. Consult manufacturer and insert requirements. |
Door leaf | |
Thickness | 75 mm. |
Panel details | Solid infill and spandrel panels to be tested and classified to Class A2-s1, d0 or A1 according to BS EN 13501 1:2007+A1:2009 for reaction to fire. Panel U-value to be 1.0 W/m²K (or less). Panels to have rigid edges. Guidance for specification option: External facing, internal facing and insulation: Consult manufacturer and insert requirements. |
Material | Aluminium. |
Perimeter seals | EPDM weather. |
Glazing | |
Type | Double-glazed units. Guidance for specification option:
|
Manifestation | Not required. Required. Guidance for specification option: Manifestation design and location to be confirmed by the contract administrator. Recommendations of the Glass and Glazing Federation should be adhered to. Insert requirements or refer to a drawing. |
Beading | |
Type | Internal. |
Finish | |
Coating | Powder coating to BS EN 12206-1. Guidance for specification option: Any special warranties or guarantees (such as marine or industrial/ chlorine) to be issued directly by the powder supplier and agreed prior to material order. Anodizing to BS 3987. Manufacturer guidanceAll finishing to be undertaken by Hydro Building Systems prior to delivery to the manufacturer. |
Texture | Gloss. Matt. Satin. |
External colour | Standard Technal finish. Manufacturer guidanceStandard Technal finish (RAL, gloss level and classification TBC) from standard Technal range. Consult manufacturer and insert requirements. |
Internal colour | Standard Technal finish. Manufacturer guidanceStandard Technal finish (RAL, gloss level and classification TBC) from standard Technal range. Consult manufacturer and insert requirements. |
Film thickness (minimum) | 60 microns. |
Hardware | TPZ62011 2-part Butt hinge. TPZ62014 3-part Butt hinge. TPZ62017 2-part Built on hinge. TPZ62020 3-part Built on hinge. TPY3638 Concealed hinge. |
UK exposure category | 1200 Pa. Guidance for specification option: Notwithstanding any information within this specification, all framing and infills shall be capable of withstanding the design wind loadings calculated in accordance BS EN 1991-1-4, and imposed loads as defined in BS EN 1991-1-1, and the specialist contractor shall carry out calculations to demonstrate this. |
Air permeability | To EN 14351-1+A1, Class 4 (600 Pa). |
Watertightness | To EN 14351-1+A1, Class E5A (200 Pa). |
Resistance to wind load | To EN 14351-1+A1, Class C3 (1200 Pa). |
Louvres | Glazed-in louvres to be tested and classified to Class A2-s1, d0 or A1 according to BS EN 13501-1:2007+A1:2009 for reaction to fire. Guidance for specification option: Blades, surface finish, fixing: Consult manufacturer and insert requirements. |
Handles | Technal Selection single or double lever handles with rosette or long plate handle with square spindle of 8 mm. External pull knob handle. Pull tubular handles. Stainless steel pull handles. Technal TCZ61027/61053 aluminium lever handles and a 5 pin anti-drill/bump resistant cylinder complying with Kitemark BS EN 1303. Guidance for specification option: Cylinder to be double cylinder/ cylinder thumbturn/ single cylinder/single thumbturn. Insert requirements. |
Closers | Face mounted closer EN 2/3/5 or EN 1 to 5 to suit door size and weight and opening and closing forces. |
Locking | T11 3/4-point lock to master leaf with central latch and deadbolt and with additional hook bolt and dual round bolts top and bottom, key operated - with optional roller latch. T3 3/4-point lock to master leaf with central latch and deadbolt and with additional hook bolt top and bottom, key or lever operated - with optional roller latch. T4 3/4-point lock to master leaf with central latch and deadbolt and with additional automatic dead locking latch top and bottom. With/ without day function. Key operated. 5 pin anti-drill/bump resistant cylinder complying with Kitemark BS EN 1303. Guidance for specification option: Cylinder to be double cylinder/ cylinder thumbturn/ single cylinder/single thumbturn. Insert requirements. Central and side adjustable strikes with stainless steel face. |
Third-party certification | BM Trada Q Mark, UL, IFT. |
FrameMaterial | Recycled content: Minimum of 75% recycled end-of-life aluminium (post-consumer scrap). |
Verification | Submit EcoPlatform third party published EPD conforming to ISO 14025 and EN 15804+A2. Proof of calculation of U-values to EN 10077-2 to be provided by specialist contractor. |
Contains Red List materials | No |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Material | Aluminium Polyamide Acrylonitrile butadiene styrene (ABS) |
A1-A3 (production stage) | Embodied carbon as defined in BS EN 15804 |
Normalised unit | 1.9 kg CO₂ eq/kg |
Declared unit | 1.9 kg CO₂ eq/kg Self-declared Lower emissions |
Recyclability | 95% |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 75 % |
Platform | Compatible | Version |
---|---|---|
![]() | - | 1 |