Verified by manufacturer 3 months ago
Aluminium sheets, AP 22/50-S profile
Aluminium and steel soffit profiles and panels.
Soffit cladding profiles and panels.
Applications include: Educational and leisure facilities, commercial premises, offices and manufacturing facilities.
Aluminium and steel soffit profiles and panels.
Features and benefits:
System components:
Color | Silver Guidance for specification option: Aluminium or steel. Other Guidance for specification option: Standard and RAL colours available. Manufacturer guidanceAluminium/ Steel: Standard APL Range; Bespoke upon request. Cor-Ten: Unweathered. |
Finish | Powder-coated Guidance for specification option: Class 1 or Class 2 Full RAL colour range and / or contact APL for additional finishes such as anodised-look Anodized Guidance for specification option: Contact APL for details Natural Guidance for specification option: Smooth mill-finish aluminium Unweathered Cor-Ten Embossed Guidance for specification option: Stucco-embossed mill-finish aluminium or Armacoil™ HDP (Subject to minimum quantity) Painted Guidance for specification option: Aluminium with Armacoil™ HDP (Subject to minimum quantity) Steel with APL PUF, PRISMA or Leathergrain Plastisol Manufacturer guidancePPC, Armacoil™ HDP, Anodised, APL PUF, Stucco-Embossed Mill-Finish (SEMF), Smooth Mill Finish (MF). Natural, PRISMA |
Material | Aluminium Steel Cor-Ten |
Shape | Other Guidance for specification option: Trapezoidal. |
Length | Bespoke |
Width | 1000 mm Guidance for specification option: Cover width, AP22/50 S. Bespoke Guidance for specification option: Slimwall™ - MODULE WIDTHS (Face + Joint)
|
Height | 20 mm Guidance for specification option: AP22/50 S. 24 mm Guidance for specification option: SFP24-S. 42 mm Guidance for specification option: SFP42-S. 35 mm Guidance for specification option: CPS-SSF-S. |
Warranty description | 25 year Guidance for specification option: Cladshield™ fully-installed system warranty available; consult manufacturer for details. |
Uniclass | |
CAWS | H31/10 Metal H31/120 Metal |
Liner sheets | |
Material | AP19 LPH profile in 0.4 mm steel in off-white 80F - solid. |
Primary fasteners | APL P191/HH fixing range. |
End and side laps | Minimum 75 mm; APL P191/HH fixing range at one per mid span, APL P103 + P108/VCT side lap sealant range, P152 Flute Fillers. |
Air and vapour control layer | |
Material | Cladding rails: AP19 LPH Liner sheet.SFS/ blockwork substrate/ timber: Other.Guidance for specification option: Refer to relevant manufacturer and insert requirements. |
Fasteners | Cladding rails: To suit AP19 LPH liner sheet.Guidance for specification option: Consult manufacturer for details. SFS/ blockwork substrate/ timber: Other.Guidance for specification option: Refer to relevant manufacturer and insert requirements. |
Sealing | Cladding rails: As per liner sheet, side laps sealed with 2x runs of P108/VCT.Guidance for specification option: Consult manufacturer for details. SFS/ blockwork substrate/ timber: Other.Guidance for specification option: Refer to relevant manufacturer and insert requirements. |
Spacers | Tritherm Spacer System® - Fully-Filled Cavity.Guidance for specification option: With cladding rails or SFS/ blockwork: P546 Isopad, P157 HH Bracket, P600 + P601 Support Zed. Tritherm Spacer System® - Ventilated Cavity - aluminium sub-frame.Guidance for specification option: SFS/ Blockwork/ timber substrate: 546 Isopad, P157-ALU HH Bracket, P759 ALU L-Rail, P760 ALU T-Rail. Manufacturer guidanceConsult manufacturer for details and insert further requirements if applicable. |
Acoustic insulation | A1-rated with thickness and performance specification as required to meet performance.Guidance for specification option: Contact manufacturer for details and insert details as required. Manufacturer guidanceA1-rated, insert thickness as required to meet Acoustic Requirement. |
Thermal insulation | A1-rated.Guidance for specification option: Insert thickness as required to meet U-value requirement with minimum lambda of 0.040 for all calculation purposes. Refer to the relevant U-value table in the supporting literature. |
Soffit | |
Material | AP22/50S aluminium profiled sheets, solid.AP22/50S aluminium profiled sheets, perforated (Airwall™).Manufacturer guidance0.9 mm thick, trapezoidal profile; cover width: 1000 mm. Consult manufacturer's literature for further details. |
Fasteners | Primary/ secondary: APL 191/LP fixing range; colour matched as required. |
Jointing | End lap: 125 mm; APL 191/LP fixing range (colour matched as required); side laps stitched at maximum 400 mm centres; APL P109/GGB sealant 6 mm Ø for side laps and end laps; APL P152/HP flute fillers. |
Glazing | Required.Guidance for specification option: Insert requirements. Not required. |
System accessories | APL system flashings.APL fixings (P191 & P192).APL sealants.P152 profile flute fillers.Manufacturer guidanceAs APL recommendations and to match profiles. Omit if already covered by soffit details. |
Colour/ Finish | Armacoil™ HDP. Guidance for specification option: Subject to minimum quantities. Insert colour required. Anodized. Guidance for specification option: Contact APL for details. Polyester powder-coating, class 1. Guidance for specification option: Insert colour/ finish required. Polyester powder-coating, class 2. Guidance for specification option: Insert colour/ finish required. Stucco-Embossed Mill-Finish (SEMF). Manufacturer guidanceInsert colour requirements. Consult manufacturer for further details as required. |
Recycled content (minimum) | Up to 95%. |
Liner Supports | Guidance for specification option: Subject to loadings. Centres are to general areas only, closer at high load zones. Purlins at maximum 1800 mm centres in general areas, closer at high load zone/corners. |
Profile supports | Guidance for specification option: Subject to loadings. Centres are to general areas only, closer at high load zones. To general areas: P665 brackets at maximum 1500 mm centres along each purlin, P030 fixed to every bracket; closer at high load zones/corners. |
NominalThickness | Manufacturer guidanceContact APL for details and insert requirements. |
Contains Red List materials | No |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Recyclability | High |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | % Guidance for specification option: Subject to substrate (steel or aluminium) and grade of aluminium |
AP22/50S - Aluminium - Soffit Data sheet
AP22/50S - Steel - Soffit Data sheet
APL Tritherm Spacer System℗ - Aluminium - Data Sheet
APL Tritherm Spacer System - Roofing - System Summary
APL Tritherm Spacer System℗ - STEEL - Data Sheet
APL Liner Profiles - Roofing & Cladding - System Summary
APL Liner Profiles - Roofing & Cladding - Data Sheet
APL Soffit System Brochure
APL Airwall™ - System Summary
APL Armacoil™HDP + HDP-HT - Product Brochure
U-Values + Build Up - WALLS - Vertical Orientation to SFS / Blockwork
U-Values + Build Up - WALLS - Vertical Orientation to Cladding Rails
U-Values + Build Up - WALLS - Horizontal Orientation to SFS / Blockwork
U-Values + Build Up - WALLS - Horizontal Orientation to Cladding Rails
APL Cladding Systems Brochure
APL StrongBak™ - Cladding - System Brochure
APL StrongBak™ - System Summary
APL AluE™ Tritherm™ Aluminium Spacer System - Cladding - System Summary