NBS Source
I'm a manufacturer

Smoke Lift Rooflight F100 W - AOV Smoke vent SHEV

Verified by manufacturer 2 months ago

Lamilux Rooflights Ltd Third party certifications:
  • EPD

    EPD

    Certificate type

  • TUV - Safety and Quality Report

    Certificate type

AOV rooflight for SHEV - smoke and heat exhaust ventilation.

Jump to:
01284 749051 Website

Application

For flat roofs of production buildings, warehouses, and sports and exhibition halls.

Description

The basis for the Smoke Lift Rooflight F100​ W is the Rooflight F100 W, which means that all of the benefits of the Rooflight F100 W are incorporated into this smoke vent rooflight. With a solution for natural daylight to enter the building and an added benefit of EN12101-2 certified smoke ventilation, the Smoke Lift Rooflight F100 W is ideal for many applications.

The Smoke Lift Rooflight F100 W consists of polycarbonate wave shaped triple layered opal glazing giving added stability to the traditional dome shape plus the system required to control the SHEV function.


Features and benefits:

  • Opens into the SHEV position in less than 60 seconds.
  • Multi layered double sealing system reduces the risk of condensation, mould growth and air leakage.
  • A full range of sizes available to give the required aerodynamic free area for a certified smoke vent.
  • GRP heat-insulated upstand with seamless silk-white interior finish removes the need of internal plastering.
  • Delivered as fully pre-assembled unit with PVC cap flashing included as standard for quick and easy installation on site by others.

General information

Color

White

Finish

Smooth

Material

Plastic

PVC

Guidance for specification option:

Polyvinyl chloride (PVC).

Aluminium

Steel

Polycarbonate

Shape

Square

Length

1200 mm

Width

1200 mm

Uniclass

Pr_70_65_04_56 Natural smoke and heat exhaust ventilatorsPrimary
Pr_30_59_72_31 Framed rooflights

CAWS

L10/45 Rooflights

L10/460 Rooflights

L10/490 Roof ventilators

Product range

Smoke ventilation

Specification data - Natural smoke and heat exhaust ventilators

Standard

To EN 12101-2.

Opening type

Single flap. Multi-stage ventilation fitted as standard.

Mounting

Roof-mounted.

Aerodynamic free area

1.02 m².

Guidance for specification option:

Non-standard sizes are available on request.

Reliability classification

Re 1000.

Guidance for specification option:

Functional reliability tested: Re1000 times in SHEV position and 10 000 times in ventilation position.

Snow load classification

SL 500—SL 2400.

Guidance for specification option:

Dependent on the size and weight of flaps.

Low ambient temperature classification

T (-15).

Wind load classification

WL 1500.

Guidance for specification option:

To DIN EN 1873 .

Resistance to heat classification

B300.

Arrangement

(PETG) domed glazing.

Dimensions

-

Length

1200 mm.

Guidance for specification option:

F100D-S1-S: 1200 x 1200mm (Aa 1.02m²). Structural roof opening size. Non-standard sizes are available on request.

Width

1200 mm.

Guidance for specification option:

F100D-S1-S: 1200 x 1200mm (Aa 1.02m²). Structural roof opening size. Non-standard sizes are available on request.

Controls

SHEV fitting - 24 v solo motor 7.5 A.

Guidance for specification option:

Opening angle approximately 165°.

Materials

-

Ventilator

-

Frame

PVC.

Glazing

Impact resistant polyethylene (PETG) domed triple layered opal glazing.

Guidance for specification option:

Non-standard glazing options are available on request.

Colour

White (RAL 9016).

Integral upstands

-

Material

300 mm high fully insulated GRP upstand - factory fitted.

Guidance for specification option:

Non-standard upstand options are available on request.

Finish

Internal (with no joints), white matt silk finish.

Colour

RAL 9016.

Watertightness

To DIN EN 1873.

Air permeability

To DIN EN 1873.

Ingress protection (IP) rating

IP54.

Operating temperature

-15°C to +75°C.

Sound insulation

Rwp 24 dB.

Light transmission

58%.

Whole window U-value

Ur: 2.4W/m²k.

Hinges

On short side.

On long side.

Manufacturer guidance

When installed in a roof pitch over 10° inclination (11–25°) unit must be hinged on the eave side.

Sustainability data

Contains Red List materials

No

Country of product manufacture

Germany

Material

Plastic

PVC

Guidance for specification option:

Polyvinyl chloride (PVC).

Aluminium

Steel

Polycarbonate

Third party certifications

BIM objects

Platform Compatible Version
Revit
-

1

Third party certifications

EPD

EPD

EDP - Barrel Vault Rooflight

TUV - Safety and Quality Report

TUV - Safety and Quality Report

ISO 50001:2011

TUV - Safety and Quality Report

TUV - Safety and Quality Report

ISO 9001 : 2015

Literature

LAMILUX SHEV Systems Brochure

LAMILUX SHEV Systems Brochure

LAMILUX Roofs of Light Brochure

LAMILUX Roofs of Light Brochure

Similar products from Lamilux Rooflights Ltd

Continuous Barrel Vault Rooflight B

Continuous Barrel Vault Rooflight B

Fire Rated Glass Roof REI 30 / REI 60 - Rooflight

Fire Rated Glass Roof REI 30 / REI 60 - Rooflight

Fire Rated Glass Skylight REI 30 / REI 60 / REI 90 - Rooflight

Fire Rated Glass Skylight REI 30 / REI 60 / REI 90 - Rooflight

Glass Roof PR60 glazed rooflight - Rooflight / Glass Atrium

Glass Roof PR60 glazed rooflight - Rooflight / Glass Atrium

Glass Roof PR60 Passivhaus Rooflight

Glass Roof PR60 Passivhaus Rooflight

Glass Skylight F100 - rooflight

Glass Skylight F100 - rooflight

Glass Skylight F100 Circular - rooflight

Glass Skylight F100 Circular - rooflight

Glass Skylight FE 3°  - Rooflight

Glass Skylight FE 3° - Rooflight

Glass Skylight FE Circular - rooflight

Glass Skylight FE Circular - rooflight

Glass Skylight FE Passivhaus - Rooflight

Glass Skylight FE Passivhaus - Rooflight