NBS Source
I'm a manufacturer
Compare variants

SLIM - Heat Recovery Unit

Verified by manufacturer 3 months ago

SLIM 1200 L - 5153137500

S&P UK Ventilation Systems Ltd Variant:

Counter flow, high efficiency heat recovery units.

Jump to:
BOS
+44 (0)1473 276890 Website

Application

  • Public buildings, offices, stores, schools and restaurants.
  • Suited for both newly constructed buildings and renovation projects.

Description

Low-profile heat recovery units specially designed for false ceiling installation (indoors). Aluminium counter-flow heat exchanger up to 92% efficiency (EUROVENT certified), plug-fans with backward curved metal blades and EC motor. Integrated bypass (100%) for free-cooling and defrost. Suited for airflows up to 2000 m³/h. Pre-configured control system for easy startup with touch screen. The casing is made of 30 mm self-supporting double skinned panels (mineral wool, 100 kg/m³, thermal conductivity 0.037 W/mK). The inner and outer skin are made from galvanized steel. Easy access to all the components via the bottom access over generously sized sliding doors. Filters are accessible from the side as well. Rectangular inlet and discharge connections.


Versions available:

Left hand/ right hand. With integrated electric preheater/ without preheater.


Sizes by nominal airflow at 250–300 Pa:

800 m³/h, 1200 m³/h, 1600 m³/h, and 2000 m³/h.


Options:

Integral preheater module. SLIM units can be ordered with the preheater module mounted from factory or as an accessory to be installed on site.


Accessory modules (post-treatment):

External modules specially designed for the range.

  • Electric battery.
  • Hot water coil.
  • Cold water coil.
  • Reversible water coil for heating/ cooling.
  • Direct expansion coil.


Filter:

  • M5 (ePM10 50%) filter on the extract air side to protect the heat exchanger.
  • F7 (ePM1 50%) filter on the outdoor air side. It is possible to replace the F7 filter by a F9 (ePM1 80%) type on site.
  • The filter clogging is controlled by differential pressure switches.


Control system:

  • Built-in programable control system (plug and play).
  • Modbus RTU (RS485) and BACNET IP communication protocol. Remote touchscreen panel included. 


Features and benefits:

  • Sliding access doors.
  • One man maintenance.
  • Integrated condensation pump.
  • Easy installing.
  • Patented tight filter system.
  • Good air quality.
  • Patented module fixation.
  • Clean design.
  • Bottom and side access to the filters.
  • Easy maintenance.
  • All main components are easily removable.
  • Separate electrical cabinet facilitates commissioning and service.

General information

Finish

Galvanized

Material

Steel

Shape

Rectangle

Length

-

Manufacturer guidance

Dependent on model specified.

Width

-

Manufacturer guidance

Dependent on model specified.

Height

-

Manufacturer guidance

Dependent on model specified.

Uniclass

Pr_60_65_03_87 Supply and return air-handling unitsPrimary

Specification data - Supply and return air-handling units

Duty

-

Air volume

-

Supply

1200 m³/h.

Extract

1200 m³/h.

Sound power level

69 dB(A).

Environment

Internal.

Casing construction

-

Material

Galvanized sheet steel.

Finish

Galvanized.

Components

-

Filters

M5 (ePM10 50%) filter and F7 (ePM1 50%) filter.

Guidance for specification option:

  • M5: Filter on the extract air side to protect the heat exchanger.
  • F7: On the outdoor air side.
  • It is possible to replace the F7 filter with an F9 (ePM1 80%) type on site.
  • The filter clogging is controlled by differential pressure switches.

Heaters

-

Pre-heaters

Without preheater.

Supply fan

-

Fan type

Plug fans.

Accessories

Not required.

SL-DI Electric heater.

Guidance for specification option:

External module that includes an electrical battery.

SL-DC Hot water coil.

Guidance for specification option:

External module that includes a hot water coil. Suitable to be combined with 2 tube-systems.

SL-DFR Reversible water coil (hot/cold water).

Guidance for specification option:

External module that includes a reversible water coil. Suitable to be combined with 2 tubes systems, both for heating and cooling applications.

SL-DF Cold water coil.

Guidance for specification option:

External module that includes a chilled water coil. Suitable to be combined with 2 tube-systems.

SL-DX Direct expansion coil.

Guidance for specification option:

External module that includes a direct expansion coil for R-410A.

IJK - Manual motorisable dampers.

Guidance for specification option:

Supplied with standard rectangular flanges. Manufactured from galvanized sheet steel.

IAE - Rectangular flexible connection.

LF 230 S - On-off actuator with spring return.

Guidance for specification option:

Power supply: 230 V 50 Hz.

Three way valve with proportional actuator.

Guidance for specification option:

Three way motorised control valve. Required accessory for external modules (water coils). Refer to the SLIM Series Catalogue for details and insert requirements.

AIRSENS CO2.

Guidance for specification option:

Indoor air-quality control device with a built-in CO2 sensor.

TDP-S - Presure sensor.

SCO2-G 0/10V - CO2 sensor.

Guidance for specification option:

For duct installation.

Manufacturer guidance

Accessory modules (post-treatment). Refer to the SLIM Series Catalogue for details.

Control

Built-in programable control system (plug and play).

Guidance for specification option:

  • Modbus RTU (RS485) and BACNET IP communication protocol.
  • Remote touchscreen panel included. 

Dimensions

1700 x 1560 x 380 mm.

Power supply

1/230 V, 50 Hz.

Configuration

Left handed.

Sustainability data

Material

Steel

BIM objects

BOS

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.

Find out more about the NBS BIM Object Standard.

Platform Compatible Version
Revit
-

1

IFC
-

1

Literature

SLIM Catalogue

SLIM Catalogue