NBS Source
I'm a manufacturer
Compare variants

Sliding Rooflight / Sliding Walk On Floor - Sky.by.cantifix

Verified by manufacturer 2 months ago

Sliding rooflight

Cantifix Ltd Variant:
Third party certifications:
  • Weathertightness Testing

    Certificate type

  • ISO 10140-2:2010 Sound Reduction Index Certificate

    ISO 10140-2:2010 Sound Reduction Index Certificate

    Certificate type

  • EN 1627-1630 RC3

    EN 1627-1630 RC3

    Certificate type

Sliding rooflight with one or more panels sliding over one or more fixed panels. Includes a variation for a sliding floor for roof access with a single panel sliding away from the opening.

Jump to:
+44 (0)20 8203 6203 Website

Application

Rooflights and ventilation.

Description

Sliding rooflight with one or more panels sliding over one or more fixed panels. Includes a variation for a sliding floor for roof access with a single panel sliding away from the opening.


Features and benefits:

  • Frame is a combination of thermally broken aluminium profile with fully cleated corners and steel profiles depending on the dimensions.
  • Frame is fully assembled and thermally isolated with Nylon and XPS insulation.
  • Standard clear double-glazed or triple-glazed units with a variety of low-E coating to give a minimum centre pane U-value of 0.6 W/m²K.
  • All glass is safety glass in either toughened or heat-strengthened laminate.
  • Options include low iron glass, solar control coatings along with acoustic or security interlayers.
  • Unsupported spans up to 6 m.

General information

Color

Clear

Guidance for specification option:

Glass.

Other

Guidance for specification option:

Framing.

Material

Glass

High density extruded polystyrene (XPS)

Stainless steel

Steel

Nylon

Show more

Shape

Rectangle

Length

Bespoke

Width

Bespoke

Uniclass

Pr_30_59_72_31 Framed rooflightsPrimary

CAWS

L10/45 Rooflights

L10/460 Rooflights

Specification data - Framed rooflights

Form

Sliding rooflight – single panel roof.

Sliding rooflight – Single panel over fixed.

Sliding rooflight - Double panel over fixed.

Sliding rooflight – Double panel over fixed 2+2.

Sliding rooflight – Multipanels.

Sliding rooflight - canopy.

Sliding rooflight - bespoke configuration.

Guidance for specification option:

Consult manufacturer for options and insert requirements.

Size

Guidance for specification option:

Insert requirements. Unsupported spans up to 6 m.

Product performance

-

Whole window U-value

To BS EN 10077, <1.4 W/m²K.
0.6 W/m²K (centre pane, minimum).

Guidance for specification option:

Consult manufacturer for details based on related details, or U-value requirements.

Frame

-

Material

Aluminium.

Manufacturer guidance

A combination of thermally broken aluminium profile with fully cleated corners and steel profiles depending on the dimensions.

Fully assembled and thermally isolated with Nylon and XPS insulation.

Finish

-

Coating

Powder coating.

Colour

Guidance for specification option:

Insert requirements; powder coated in any standard RAL colour.

Film thickness (minimum)

Manufacturer's standard.

Glazing or infill

-

Type

Toughened safety glass.

Heat-strengthened laminate safety glass.

Other.

Guidance for specification option:

Consult manufacturer for alternatives and insert requirements. Options include low iron glass, along with acoustic or security interlayers.


See Coatings for further options.

Construction

Double glazed.

Triple glazed.

Colour

Clear.

Coating

Low-E to achieve minimum centre pane U-value of 0.6 W/m²K.

Guidance for specification option:

Standard.

Solar control.

Operation

-

Type

Powered, electric.

Guidance for specification option:

Belt-driven by synchronised electronic motors.

Control

By internal open/ close toggle switch through dead-man operation.

Guidance for specification option:

Standard, belt-driven by synchronised electronic motors controlled through central Printed Circuit Board (pcb). 


The whole 24 V system is designed to be 'plug and play'.

External control through rain, wind and light sensors.

External control through biometric device.

External control through remote-control module.

Manufacturer guidance

See also Power supply for UPS option.

Power supply

Standard.

Uninterrupted power supply (UPS).

Guidance for specification option:

Achieved by installing a battery backup to allow for operation even during power outage.

Ironmongery

All fittings in aluminium, stainless steel (304), printed from ABS material or other non-corrosive material.
Solenoid dead-locking when roof is closed.

Guidance for specification option:

Consult manufacturer for details as required.

Air permeability

To BS EN 12207, Class 3 at 600 Pa.

Resistance to wind load

To BS EN 12210, Class E2400.

Watertightness

To BS EN 12208, Class 6A (9A).

Performance characteristics

CWCT classification (TN92): Class 2 (if four-edge supported and panels <4.5 m²).

Sustainability data

Contains Red List materials

No

Country of material origin

Poland

Country of product manufacture

Poland

Material

Glass

High density extruded polystyrene (XPS)

Stainless steel

Steel

Nylon

Show more

Manufacturing plant location

Expected Life

25 year

Third party certifications

Weathertightness Testing

Weathertightness Testing

Weathertightness Testing - Single Sliding Panel

ISO 10140-2:2010 Sound Reduction Index Certificate

ISO 10140-2:2010 Sound Reduction Index Certificate

Sound Insulation / dB rating certification - Single Sliding Panel

EN 1627-1630 RC3

EN 1627-1630 RC3

EN1627:2011 Security Testing – Sliding rooflights all types

Weathertightness Testing

Weathertightness Testing

Weathertightness Testing – Multi panels sliding rooflight

Literature

L11 - sky.by.cantifix slide-over Rooflight / floor

L11 - sky.by.cantifix slide-over Rooflight / floor

L11 - sky.by.cantifix sliding Rooflight

L11 - sky.by.cantifix sliding Rooflight