Patent glazing system with slim, external extruded aluminium capping.
To be used to the external facade of a patent glazing system in commercial and domestic applications, and can accommodate the following:
Two edge supported patent glazing system with slim, external extruded aluminium capping.
Features and benefits:
Applications:
To be used to the external facade of a patent glazing system in commercial and domestic applications, and can accommodate the following:
Material | Grade 6063 temper T6 aluminium alloy, conforming to BS EN 755-2 |
Uniclass 2015 | |
CAWS | H10/10 Patent glazing H10/115 Patent glazing |
Product Reference | Skyline Patent Glazing System |
Supporting structure | - |
Top | Suitably pitched steel railsSuitably pitched timber rails |
Intermediate | Not requiredSuitably pitched steel railsSuitably pitched timber rails |
Bottom | Suitably pitched steel railsSuitably pitched timber rails |
Glazing bar | - |
Type | SPG2Depth: 55 mm. SPG3Depth: 75 mm. SPG4Depth: 100 mm. |
Capping | - |
External | PC2, plain square edged extruded aluminium capPC3, ornate extruded aluminium profiled cap |
Internal | Not requiredPC4, ornate extruded aluminium profiled inner capFully conceals the internal stalk, giving the appearance of a feature timber rafter. |
Colour/ Finish | Polyester powder-coated to BS 6496Insert non-metallic RAL colour from the standard range. Untreated (mill finish) |
Slope | 15°20°25°30°35°40°45° |
Infill | Consult manufacturer's literature and insert requirements. |
Opening vents | - |
Type | Not requiredBottom hung, thermally brokenNot available for single glazing. Side hung, thermally brokenTop hung, thermally broken |
Quantity | 1–20. Consult manufacturer and insert requirements. If opening vents are not required, insert N/A. |
Operation | Not applicableElectric control - chain actuator, 24 VElectric control - chain actuator, 230 VElectric control - linear actuator, 24 VElectric control - linear actuator, 230 VManual control - screwjack gearPneumatic control - gas springs |
Controls | Not applicable/ not requiredCrank handleFor use with screwjack gear. Standard open/ close wall mounted switchFor electric actuators. Wall mounted thermostatic control panel with rain sensorFor electric actuators. |
Accessories/ Other requirements | Not requiredDress only lead flashingsTo perimeter positions (lead flashings measured elsewhere). Pre-formed sheet aluminium flashingsTo perimeter positions. |
Standard product features | Material: Grade 6063 temper T6 aluminium alloy, conforming to BS EN 755-2. Pressure cap: PC1, extruded aluminium cap. Minimum film thickness: 40 µm. Glazing bar spacing: Approximately 600 mm centres. |
Product Options | Glazing bar: Consult manufacturer before specifying a particular glazing bar. - SPG2:
- SPG3:
- SPG4:
Please note that the lower span values are calculated using the most extreme environmental loadings, whereas the higher span values are based on the least extreme. The manufacturer requests a site postal code to enable them to calculate the correct glazing bar type for every project. The glazing bar spans above are based on using 6 mm thick glass for the double glazed, single glazed and canopy types. Spans are dependent upon the site location and exposure rating, site altitude, distance from the sea, height of glazing from ground level, shape of the roof, pitch of glazing, glazing bar centres, glass weight, wind speeds, snow load, dead load and maintenance loads. Glazing infill: A variety is available, e.g. clear laminated, heat soaked toughened, etc. Consult manufacturer's literature for information.
A 16 mm Argon gas filled cavity with warm edge spacer bars is supplied for double and triple glazing. |