NBS Source
I'm a manufacturer

Sikaplan®-1650 DPM - Gas Barrier

Verified by manufacturer 3 months ago

Sika Limited

Multi-layer, low density polyethylene membrane for ground level damp proofing.

Jump to:
+44 (0)1707 394444 Website

Application

Suitable uses:

  • Ground level DPM.
  • Building protection from ground gases, radon, methane and carbon dioxide.

Description

Sikaplan®-1650 DPM Gas Barrier is a multi-layer, low density polyethylene membrane, reinforced with a polypropylene reinforcing grid with an integral aluminium foil. It is specifically designed and manufactured to perform as a methane, carbon dioxide, radon ground gas, air and moisture protection system.


Features and benefits:

  • Fully tested to BS 8485:2015+ A1:2019.
  • Welded joints for improving sealing.
  • In-build grid to give greater strength.
  • Fully compatible with below ground waterproofing systems.


Approvals/ standards:

  • Conforms to the requirements of EN13967:2012 and BS 8485:2015+ A1:2019.
  • NHBC Standards Compliant.
  • BBA Certified – Certificate No: 20/5738.

General information

Color

Black

Finish

Other

Material

Polyethylene

Polypropylene

Aluminium

Shape

Other

Length

50000 mm

Width

2000 mm

Height

0.6 mm

Uniclass

Pr_25_57_21_35 Gas-resistant damp-proof coursesPrimary

CAWS

F30/360 Gas-resistant damp-proof courses/ cavity trays

F30/54 Gas-resistant dpcs/ cavity trays

Product range

Waterproofing

Specification data - Gas-resistant damp-proof courses

Third party certification

British Board of Agrément (BBA) certified.

Guidance for specification option:

Certificate number 20/5738.

Material

Polyethylene with reinforcing grid of high density polyethylene and integral aluminium foil.

Overall thickness

To EN 1849-2, 0.6 m.

Guidance for specification option:

Thickness between scrim 0.4 mm Micrometre.

Width

To EN 1849-2, 2 m.

Length

To EN 1849-2, 50 m.

Weight

To EN 1849-2, 370 g/m².

TensileStrength

To EN 12311-1, 600 N/50 mm (MD); 480 N/50 mm (CMD).

Elongation

To EN 12310-1, 20% (MD and CMD).

Puncture resistance

To EN 12236, 1.25 kN.

Manufacturer guidance

Resistance to static puncture.

Static load resistance

To EN 12730-B, 20 kg.

Watertightness

To EN 1296, EN 1367 and EN 1928, Pass.

Methane permeability

To BS EN ISO 15105-1, <0.09 ml/m²/day/atm.

Carbon dioxide permeability

To BS EN ISO 15105-1, <0.09 ml/m²/day/atm.

Radon permeability

To K124/02/95, 8.0 x 10-¹⁵ m²/s.

Reaction to fire (to EN 13501-1)

Class E.

Third-party certification

British Board of Agrément (BBA) certificate.