Siderise RV vertical cavity barriers for rainscreen cladding are used to full fill the void between the external envelope and internal substrate.

Jump to:
BOS
+44 (0) 1656 730 833 Website

Application

Siderise RV vertical cavity barriers for rainscreen cladding are used to full fill the void between the external envelope and internal substrate.

The construction of RV vertical cavity barriers offers resistance to the passage of fire. Additionally, by fully sealing the void, they assist ventilated façades to function by maintaining air-pressurisation compartmentation.

Significantly, their unique stone wool lamella core construction enables the vertical barriers to accommodate the serviceability movement normally associated with rainscreen façades.

Intersections between horizontal and vertical cavity barriers are simply abutted, with RFT 120/45 foil tape applied as detailed in the RV Installation Instructions. The leading edge compresses directly against the external envelope. No intumescent strip is required.

Description

Siderise RV vertical cavity barriers for rainscreen cladding applications consist of a non-combustible stone wool lamella core, with reinforced aluminium foil faces.

Siderise RV vertical cavity barriers are installed within the cavity, formed between the rainscreen facade and the inner structural wall, using the appropriate Siderise support brackets. Brackets are available in either galvanised mild steel (G) or stainless steel (S).

The standard product length is 1200mm.

Features and benefits:

  • Siderise RV Cavity Barriers provides a fire resistance of up to 120 minutes of integrity and 120 minutes insulation. (Siderise RV-120/120 & Siderise RV120/120X).
  • Siderise RV Cavity Barriers are fully compliant and meet ASFP guidelines.
  • Siderise RV Cavity Barriers are suitable for vertical (full seal) applications.
  • Siderise RV Cavity Barriers accommodate cladding movement.
  • Siderise RV Cavity Barriers are tested to BS EN 1366-4:2006+A1:2010.
  • Siderise RV Cavity Barriers are Third-party approved: Intertek US(WHI20-32944302 ), Intertel UK(WHI-09-02-22-000001-02), IFC Certification (IFCC 1712).
  • Siderise RV Cavity Barriers have been used in several large-scale system tests such as BS 8414 (1 and 2) and NFPA 285.

General information

Color

Silver

Brown

Yellow

Green

Manufacturer guidance

Solid, green-brown exposed edges with silver aluminium on both facings.

Finish

Foil

Material

Stonewool

Shape

Rectangle

Length

1200 mm

Width

20 mm

Guidance for specification option:

Minimum.

400 mm

Guidance for specification option:

Maximum.

Manufacturer guidance

Cavity width

Height

75 mm

100 mm

120 mm

Manufacturer guidance

Thickness

Uniclass

Pr_25_80_80_79 Sleeved mineral wool cavity barriersPrimary

CAWS

H92/776 Thermal insulation

P12/360 Mineral wool rigid batts

P12/40 Mineral wool rigid batts

SKU Code

RV

Product range

Rainscreen

Specification data - Sleeved mineral wool cavity barriers

Manufacturer

Siderise.

Third-party certification

IFCC 1712 (BS EN 1366-4).
Intertek UK WHI-09-02-22-000001(BS EN 13501-1).
Intertek US WHI20-32944302 (BS EN 13501-1).

Cavity barriers

-

Sleeves

Aluminium foil to surfaces exposed to cavity.

Size

1200 mm x (void width).

Manufacturer guidance

Can be supplied in sheets of 1200 mm x 1200 mm and cut on site to suit void width. Alternatively supplied as pre-cut in widths to suit advised void size.

Insert requirements or refer to drawing.

Fire performance

Reaction to fire to EN 13501-1; Class A1.
Fire resistance to BS EN 1366-4; 90 minutes integrity, 30 minutes insulation.

Guidance for specification option:

BS EN 1366-4:2006+A1:2010.

Type

Semi-rigid.

Configuration

Vertical.

Thickness

75 mm.

Compression

Minimum +10%.

Guidance for specification option:

Compression fit.

Cavity width

20–50 mm.

Nominal density

75 kg/m³ .

ThermalConductivity

To EN 12667, 0.038 W/m·K.

Guidance for specification option:

± 5%.

Fixing brackets

Not required.

Accessories

Siderise RFT120/45 Tape.

Weighted sound reduction index, Rw

Rw 21 (C;Ctr) (-1;-2).

Sustainability data

Contains Red List materials

No

Country of material origin

United Kingdom

Country of product manufacture

United Kingdom

Material

Stonewool

A1-A3 (production stage)

Normalised unit

1.7 kg CO₂ eq/kg

Declared unit

1.72 kg CO₂ eq/kg

Certified

Lower emissions

Recyclability

Recyclable

Manufacturer guidance

The stone wool core is recyclable

Expected Life

60 year

Guidance for specification option:

When correctly installed in open cavities in facade applications.

Product certifications

Certified

BIM objects

BOS

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.

Find out more about the NBS BIM Object Standard.

Platform Compatible Version
IFC
-

3

Revit
-

3

Product certifications

Certifire Certificate

Certifire Certificate

Certifire - Certificate of Approval No CF 6028

IFCC

IFCC

Siderise RH,RV Cavity Barriers- IFCC 1712 Certificate

Intertek

Intertek

Intertek US: WHI20-32944302 Iss. 8

EPD

EPD

EPD HUB, HUB-1302

CCPI Product

CCPI Product

CCPI 000800106/1126 - RV Cavity Barriers for Cladding/ Rainscreen - Vertical

Literature

Siderise RV | Cavity Barriers for Cladding / Rainscreen – Vertical v3.05 – Technical Data

Siderise RV | Cavity Barriers for Cladding / Rainscreen – Vertical v3.05 – Technical Data

CPD materials

Passive Fire Protection in Curtain Wall Facades. Firestopping, Perimeter Seals and Protected Spandrels

Passive Fire Protection in Curtain Wall Facades. Firestopping, Perimeter Seals and Protected Spandrels

Passive Fire Protection in Curtain Wall Facades. Firestopping, Perimeter Seals and Protected Spandrels.  (Lite Version)

Passive Fire Protection in Curtain Wall Facades. Firestopping, Perimeter Seals and Protected Spandrels. (Lite Version)

Case studies

ONE Tower, Limassol

ONE Tower, Limassol

Similar products from Siderise Group

Siderise RF Cavity Barrier and Firestop for Raised Access Floors

Siderise RF Cavity Barrier and Firestop for Raised Access Floors