Siderise OSCI Open State Cassette Insert designed for use in cassette panel cladding. Siderise OSCI Open State Cassette Insert are used horizontally or vertically as part of a cladding system.

Jump to:
BOS
+44 (0)1656 730833 Website

Application

Siderise Open State Cassette Inserts (OSCI) are designed for use in Cassette Panel Cladding Systems.

Siderise Open State Cassette Inserts (OSCI) can be used both horizontally and vertically as part of a cladding system. They are applied directly to the internal surface of the cassette panel to simplify the detailing and installation of adjacent cavity barriers and/or to ensure that the ventilation air gap is dimensioned within permissible limits.

Siderise Open State Cassette Inserts (OSCI) are positioned parallel and aligned centrally to Siderise 'RH' or 'RV' Cavity Barriers, taking into account the specification of the cladding system assembly. Typically, this requires consideration of the specification and configuration of the cladding panels, the positioning of the support rails or similar steelwork, and/or hook-on or bracket arrangements for panel support.


Siderise Open State Cassette Inserts (OSCI) should not be used in conjunction with cavity barriers from another manufacturer or type.

Description

Siderise Open State Cassette Inserts (OSCI) products are manufactured from strips of high density non-combustible stonewool (Class A1) with a foil-facing on two sides. One side has an additional high-performance modified acrylic pressure-sensitive adhesive with strippable film.

Siderise Open State Cassette Inserts (OSCI) are available in a range of sizes and are selected according to the type and size of the corresponding Siderise Open State Cavity Barrier specification on a project basis. 


Features and benefits:

  • Siderise Open State Cassette Insert (OSCI) is tested in multiple BS 8414 & NFPA 285 System Tests.
  • Can be used in combination with either RH25 or RH50 (horizontal), or RV (vertical) cavity barriers.
  • Range of thicknesses and widths to accommodate a wide array of Cassette Panel Cladding Systems.
  • Classified A2-s1, d0 to EN 13501-1.

General information

Color

Silver

Guidance for specification option:

Silver aluminium top and bottom facings

Other

Guidance for specification option:

Solid, green-brown exposed edges

Finish

Foil

Guidance for specification option:

Foil.

Material

Stonewool

Shape

Rectangle

Length

1220 mm

Width

-

Manufacturer guidance

Please see product width

Height

-

Manufacturer guidance

The depth of the OSCI can be variable with a minimum depth of 30mm. Other OSCI depths can be made available, please contact the manufacturer.


Please see product 'Depth'

Uniclass

Pr_25_57_06_56 Mineral wool slab insulationPrimary

CAWS

H92/776 Thermal insulation

P12/360 Mineral wool rigid batts

P12/40 Mineral wool rigid batts

Product range

Rainscreen

Specification data - Mineral wool slab insulation

Thickness

40 mm.

Edges

Square.

Thermal conductivity (maximum)

0.043 W/m·K.

Fire performance

To EN 13501-1, Class A2-s1, d0.

Width

100 mm.

Length

1220 mm.

Sustainability data

Contains Red List materials

No

Country of material origin

United Kingdom

Country of product manufacture

United Kingdom

Material

Stonewool

Recyclability

Recyclable

Expected Life

60 year

Guidance for specification option:

Only when used in combination with Siderise Cavity Barriers for Rainscreen Cladding but particular attention must be applied to the fixing system as detailed below:


• Keeping the product dry during both storage and installation

• Following the method of attaching the system detailed in our installation instructions

• Ensuring that the top and bottom of the ‘OSCI’ is sealed with lengths of Siderise RFT120

aluminium jointing tape to ensure a weather tight seal

• If appropriate to the project system and panel construction, use additional mechanical

retention

BIM objects

BOS

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.