Balcony bracket cavity barrier kit providing a rapid solution to a complex detail and allows continuity of cavity compartmentation when abutted either side by SIDERISE Cavity Barriers and Fire Stops.
External masonry wall build-ups.
Balcony bracket cavity barrier kit providing a rapid solution to a complex detail and allows continuity of cavity compartmentation when abutted either side by SIDERISE Cavity Barriers and Fire Stops.
Comprises a low resin content stone wool insulation core which is pre-compressed internally to form a resilient strip. The material is faced with a reinforced aluminium foil which is an effective smoke barrier.
Kit comprises of four pre-cut interlocking sections that encapsulate the balcony bracket connection.
Should be installed in accordance with PD 6697: 2019 - 'Recommendations for the design of masonry structures to BS EN 1996-1-1 and BS EN 1996-2' when used in conjunction with SIDERISE EW in external masonry wall build-ups:
Must be installed with a damp-proof course (DPC) extending a minimum of 25 mm into the cavity either side of where the product contacts the brickwork. DPC to be specified separately.
Features and benefits:
Application:
External masonry wall build-ups.
Material | Non-combustible stonewool that is rated A1 to EN 13501-1 as a standalone material and is covered in a reinforced aluminium foil |
Uniclass 2015 | |
CAWS | F30/18 Cavity closers F30/180 Cavity closers P12/360 Mineral wool rigid batts P12/40 Mineral wool rigid batts |
Product Reference | SIDERISE® BB-CB120 minutes' fire rating, EI 120. |
Spiral fixings | Insert requirement, contact manufacturer's literature for more information. |
Standard product features | Material: Non-combustible stonewool that is rated A1 to EN 13501-1 as a standalone material and is covered in a reinforced aluminium foil. |
SIDERISE CVB Acoustic Void Barriers (formerly Lamaphon CVB)
SIDERISE CW-FB curtain wall fireboard
SIDERISE CW-FS Perimeter Barriers and Firestops for Curtain Walling (formerly Lamatherm CW-FS)
Siderise EW - Cavity Barriers and Fire Stops for Masonry External Walls
SIDERISE OSCI Open State Cassette Insert
SIDERISE RF Cavity Barriers and Firestops for Raised Access Floors (formerly Lamatherm RF)
SIDERISE RH Open State Horizontal Cavity Barriers (formerly Lamatherm CW-RS)
SIDERISE RV Vertical Cavity Barriers (formerly Lamatherm CW-RS)
SIDERISE TW Firestops for Tops of Walls
SIDERISE TW-P Firestops for Profiled Decks (formerly Lamatherm TW-PP and Lamatherm TW-PS)