NBS Source
I'm a manufacturer
Compare variants

SHERPA® Goods-only Lift

Verified by manufacturer 6 months ago

Cabin width ≤1500 mm

Lödige Industries Variant:

The SHERPA® is a space-saving goods-only lift. It is a machine-room-less chain lift for low and medium height buildings with integrated shaft for the transportation of goods without attendant.

Jump to:
01784 221140 Website

Application

The SHERPA® goods lifts are a cost-effective, efficient solution and can be used for a variety of applications. The quick and easy installation does not require any construction modifications and enables uninterrupted day-to-day operations even during assembly.


The SHERPA® goods lifts are ideally suited for use in distribution and logistics companies and can easily be integrated into existing shelving systems and mezzanine levels.


In production facilities, goods can be transported between different levels more quickly and efficiently, thus greatly simplifying and improving process flows.


Whether exhibits, archive files or supplies – with our goods lifts, a quick and safe transport is ensured without affecting visitor traffic in public buildings.


In hospitals and medical facilities, medical supplies, clean laundry and groceries are delivered daily. A centrally located passenger or bed elevator is often not sufficient. Our goods lifts are a sustainable solution for optimising logistics.


In office buildings, the use of goods lifts can significantly relieve and safeguard the existing passenger lifts while increasing the attractiveness of rental space by making the transport of furniture and equipment easy.


Thanks to the fast and safe transportation of everyday necessities, waste and laundry away from the guests in hotels, our goods lifts can make a fundamental contribution to a positive visitor experience.


The installation of our SHERPA® goods lifts permanently enables the fast and safe transport of consumer goods and food between delivery and sales areas in event venues and shopping centres.

Description

Space saving goods-only lift.


Features and benefits:

  • Can be easily integrated into existing buildings or rack systems.
  • Freestanding lift structure.
  • Tailor-made cabin dimensions.
  • Minimal pit required. 70-150 mm
  • No separate machine room necessary.
  • Easy and fast installation.
  • In accordance with European Machinery Directive 2006/42/EC.
  • Energy class: A.


Technical data Sherpa:

  • Load capacity: max. 4,500 kg
  • Nominal speed: 0.2 m/s
  • Lifting height: up to 18 m
  • Cabin depth: up to 4,500 mm
  • Cabin width: up to 2,800 mm
  • Cabin height: up to 2,800 mm
  • Number of stopping points: 2 to 6
  • Door configuration: one side or through car loading
  • Power train: electric with chain
  • After machine directive 2006/42/EC


Goods with attendant lift also available, specified separately (ESCORTA®).

General information

Color

Beige

Black

Blue

Bronze

Brown

Show more

Manufacturer guidance

Contact manufacturer for any colour.

Finish

Galvanized

Material

Steel

Guidance for specification option:

Galvanized.

Shape

Rectangle

Length

Bespoke

Manufacturer guidance

1200–4500 mm.

Width

Bespoke

Manufacturer guidance

900mm to 2,800mm

Height

Bespoke

Manufacturer guidance

Cabin height 1,800mm to 2,800mm

Warranty description

One year

Uniclass

Ss_80_50_01_05 Electric accessible goods-only lift (AGOL) systemsPrimary

CAWS

X12/110 Vertical lifting platform systems

X12/110 Vertical lifting platform systems

Specification data - Electric accessible goods-only lift (AGOL) systems

Lift type

Accessible goods-only lift.

Lift components

Free-standing self-supporting lift shaft; cabin; integrated drive.

Guidance for specification option:

  • Steel lift shaft with sheet metal cladding. Supplied prime coated or galvanized.
  • Steel cabin with hinged doors (primed or painted).
  • Drive: Integrated in the shaft head.
  • Control mounted on the shaft cabinet.
  • Energy-saving gear motor with an integrated disk brake.

Door configuration

Single entrance (front only), two floors.

Guidance for specification option:

Number of entrances/ doors to match number of stops specified (See Lift height below).

Single entrance (front only), three floors.

Guidance for specification option:

Number of entrances/ doors to match number of stops specified (See Lift height below).

Single entrance (front only), four floors.

Guidance for specification option:

Number of entrances/ doors to match number of stops specified (See Lift height below).

Single entrance (front only), five floors.

Guidance for specification option:

Number of entrances/ doors to match number of stops specified (See Lift height below).

Single entrance (front only), six floors.

Guidance for specification option:

Number of entrances/ doors to match number of stops specified (See Lift height below).

Doors opposite/ through car, two floors.

Guidance for specification option:

Insert requirements for number of entrances/ doors (Two, three or four).


For each floor, define for each opening whether a double swing door or no door is required.

Doors opposite/ through car, three floors.

Guidance for specification option:

Insert requirements for number of entrances/ doors (Three, four, five or six).


For each floor, define for each opening whether a double swing door or no door is required.

Doors opposite/ through car, four floors.

Guidance for specification option:

Insert requirements for number of entrances/ doors (Four, five, six, seven or eight).


For each floor, define for each opening whether a double swing door or no door is required.

Doors opposite/ through car, five floors.

Guidance for specification option:

Insert requirements for number of entrances/ doors (Five, six, seven, eight, nine or ten).


For each floor, define for each opening whether a double swing door or no door is required.

Doors opposite/ through car, six floors.

Guidance for specification option:

Insert requirements for number of entrances/ doors (6, 7, 8, 9, 10, 11 or 12).


For each floor, define for each opening whether a double swing door or no door is required.

Drive type

Machine room-less.

Drive position

Integrated in shaft head.

Speed control

Manufacturer's standard.

Rated load

-

Manufacturer guidance

Insert requirements; 500–4500* kg.

Individually configured lifts have a load range of 500–3000* kg.


Maximum load is also dependent on cabin size specified; consult manufacturer for full details.

Pit opening

Required.

Guidance for specification option:

Pit depth required is between 70 and 150 mm, dependent on load capacity. Consult manufacturer for details.

Not required (ramp).

Guidance for specification option:

Chequered plate metal, primed in RAL 9016 Pebble grey as standard.

Other colours and/ or a side bevel available on request.

Cabin

1200 x 1800 x 2000 mm.

Guidance for specification option:

Width x depth x height.

Not available for rated loads >2500 kg.

1400 x 2000 x 2000 mm.

Guidance for specification option:

Width x depth x height.

Not available for rated loads >2500 kg.

Bespoke.

Guidance for specification option:

Insert requirements:

  • Width: 900–1500 mm.
  • Depth: 1200–3000 mm*.
  • Height: 1800–2800 mm.


Consult manufacturer if larger size is required.

System accessories

None.

Frequency converter.

Fire-rated doors, E120/ EI05/ EW30.

Fire-rated doors, E120/ EI15/ EW60.

Door dampers.

Guidance for specification option:

Prevents the door slamming shut with subsequent noise generated. Also protects the door and the door hinges.

Note: Not classified as fire-resistant under EN 81-58.

Show more

Lift height

-

Manufacturer guidance

Insert requirements for:

  • Lighting height (up to 18 000 mm).
  • Number of stops (two to six).
  • Distance between floors.

Shaft

-

Manufacturer guidance

Insert requirements:

  • Width: 1270–3600 mm.
  • Depth: 1740–4840 mm.

Colour

Galvanized.

Powder-coated.

Guidance for specification option:

Consult manufacturer for colour options and insert requirements. All common Classic RAL colours are available (metallic and neon colours are not possible).

Manufacturer guidance

Shaft colour/ finish.

Control cabinet

-

Manufacturer guidance

Insert placement requirements:

  • Floor number;
  • Position (left or right).


Painted in RAL 7035 as standard.

Ingress protection: IP54 without a frequency converter; IP44 with a a frequency converter.

The size of the control cabinet will vary depending on the lift configuration; consult manufacturer for details.

Speed

0.2 m/s.

Door configuration

Single leaf, left-hand openings only.

Guidance for specification option:

Cabin width ≤1500 mm only.

Single leaf, right-hand openings only.

Guidance for specification option:

Cabin width ≤1500 mm only.

Single leaf, left and right openings.

Guidance for specification option:

Cabin width ≤1500 mm only.

Specify left or right leaf opening per floor, front and back for through car arrangements.

Single leaf/ no door combinations.

Guidance for specification option:

Cabin width ≤1500 mm only.

Specify left or right leaf opening and/or no door combinations per floor (front and back).


Minimum of one door required per floor (adjust distance between floors if one level of the building is to be bypassed).

Manufacturer guidance

Door size determined by cabin size.

No door handle shells on the inside of the doors as standard.

Door colour

Traffic red.

Sky blue.

Dusty grey.

Primed (RAL 9016 Pebble grey).

Other, Classic RAL.

Guidance for specification option:

Consult manufacturer for options and insert requirements.

All common Classic RAL colours are available (metallic and neon colours are not possible)

Landing operating panels

Manufacturer's standard, door handle side.

Flooring

Manufacturer's standard.

Guidance for specification option:

Smooth sheet metal with a two-component anti-slip coating (epoxy resin-based, solvent-free and non-slip coating in RAL 7040).

Steel tear plate.

Guidance for specification option:

Painted to match door colour.

Aluminium tear plate.

Manufacturer guidance

For lifts up to maximum 1000 kg nominal load and maximum 1400 mm cabin width, galvanized platforms are standard.

Length

1200–4500 mm.

Sustainability data

Contains Red List materials

No

Country of product manufacture

Germany

Literature

SHERPA and ESCORTA Planning Guide

SHERPA and ESCORTA Planning Guide

SHERPA goods lift brochure

SHERPA goods lift brochure

Lifting Solutions Brochure

Lifting Solutions Brochure

Case studies

Bespoke twin goods lifts enhancing space and time in Holland and Barrett’s warehouse in Staffordshire, England

Bespoke twin goods lifts enhancing space and time in Holland and Barrett’s warehouse in Staffordshire, England

Efficient and safe goods lifts optimize performance for a large online shopping retailer’s warehouse

Efficient and safe goods lifts optimize performance for a large online shopping retailer’s warehouse

Similar products from Lödige Industries

SERWA® Mezzanine Goods Lift

SERWA® Mezzanine Goods Lift