Verified by manufacturer 1 day ago
Twin 15 mm I Stud Profile Width | 65dB | SFS4481
EPD
Certificate type
Double layer of Gyproc 15 mm Soundbloc each side of an SFS twin I Studs at 600 mm centres; with 50 or 100 mm insulation.
Plasterboard partition system suitable for severe duty applications.
Double layer of Gyproc 15 mm Soundbloc each side of an SFS twin I studs at 600 mm centres.
Features and benefits:
Finish | Other |
Material | Gypsum Steel |
Shape | Rectangle |
Length | Bespoke |
Width | Manufacturer guidanceOverall, excluding finishes. |
Height | 2800 mm Guidance for specification option: Maximum. 3900 mm Bespoke Guidance for specification option: Maximum. |
Uniclass | |
CAWS | K10/125 Metal stud partition system K10/30 Metal stud |
SKU Code | SFS4481 |
System performance | |
Sound insulation, Rw (minimum) to BS EN ISO 10140-2 or BS EN ISO 140-3 | 65 Rw (dB). Guidance for specification option: With service baffle box. Manufacturer guidanceTo BS EN ISO 10140-2. |
Duty rating to BS 5234-2 | Severe duty (SD). |
Maximum height - cold state | 2800 mm. Manufacturer guidanceBased on limiting deflection of L/240 @ 200 Pa. |
Thickness | 200 mm. Guidance for specification option: Minimum. Other. Guidance for specification option:
Manufacturer guidanceNominal, excluding finishes. |
Classification data | |
System manufacturer | Steel Formed Sections. |
Framing | Track: SFST52. Stud: 2 x SFS50I50 I studs 50 mm width at 600 mm centres, in two rows braced at 1200 mm centres. Manufacturer guidance
|
Insulation | 50 mm acoustic insulation. |
Linings | Board side 1, layer 1: Gyproc Soundbloc 15 mm. Board side 1, layer 2: Gyproc Soundbloc 15 mm. Board side 2, layer 1: Gyproc Soundbloc 15 mm. Board side 2, layer 2: Gyproc Soundbloc 15 mm. |
Fasteners | Inner layers: Drywall screw (25 mm length). Outer layers: Drywall screw (42 mm length). |
Joint treatment | Vertical joints: treated in accordance tape joint method. Horizontal joints: backed by SFS1 (flat strap) and treated in accordance with tape joint method. |
Finish | Manufacturer guidanceConsult manufacturer and insert requirements. |
System accessories | Acoustic sealant. Guidance for specification option: Sealant to both sides of partition framework. |
Fire resistance | To BS 476, 120 minutes. |
Material | Gypsum Steel |