BBA Agrément Certificate
Certificate type
PVC-P single-ply membrane with polyester reinforcement, for mechanical fastening.
PVC-P single-ply membrane system for mechanical fastening on cold roofs.
System (can) include:
- Waterproof membrane:
Sarnafil S membranes are manufactured using a state of the art extrusion coating process that eliminates shrinkage and plastic memory and produces a dynamically stable membrane. In the coating process, a polyester scrim carrier is coated on both sides with liquid Plastisol, prior to the application of a lacquer coating on the upper surface and laser marking of the membrane for identification. The unique lacquer coating eliminates the need for biocides, provides the membrane with an easy to clean surface and prolongs the life of the membrane by reducing plasticiser loss.
The process enables between 2% and 5% of recycled material to be used in the production of new membranes.
- Fleece (cushion layer):
A polypropylene fleece used either as a protective layer below the waterproof liner or as a protective layer on top of the liner.
Performance:
Certified by BBA, in their opinion, to have a "life expectancy in excess of 40 years" for exposed applications, with periodic maintenance as stated below.
A planned maintenance cycle, including inspections by the Certificate holder at minimum intervals of five years, should be introduced if an extended service life is required. The Certificate holder can advise on methods of extending the service life. This could include the use of thicker membranes, specific maintenance requirements or localised replacement and repair.
Should the maintenance cycle not be followed Sarnafil G/S membranes have been given, by the BBA in their opinion, a life expectancy of "in excess of 35 years".
Installation:
- Waterproof membrane:
Sarnafil S327-EL is mechanically attached to the substrate using either the Sarnafast or Sarnabar system and suitable Sarnafil fasteners. Laps are then hot air welded to form seams which are stronger than the membrane itself.
Installation is carried out by Sarnafil trained contractors.
- Fleece (cushion layer):
Sarnafil Type A and Type T:
Sarnafil Type A and Type T are generally loose laid, but can be partially bonded to the substrate with Sarnacol 2170 or Sarnacol 2172 if required. In either application, all edges must be overlapped by at least 100 mm.
Uniclass 2015 | |
CAWS | J42/130 Cold deck roof covering |
Product Reference | Sarnafil S327-EL Mechanically Fastened Cold Roof System |
Primer | Not requiredPrimer 110 |
Waterproof membrane | - |
Type | Sarnafil S327-EL |
Thickness | 1.2 mmAs standard. 1.5 mm1.8 mm |
Colour | Copper Patina GreenLead greyLight greyWhite RAL 9016 SR (solar reflective) |
Attachment | Mechanically fastened |
Fleece | Not requiredSarnafil Type ASarnafil Type T |
Accessories | G/S rainwater outletsSarnafil Constant Force postSarnafil heat weldable lightning conductor clipsSarnametalSarnaplast 2235 |
Standard product features | Waterproof membrane: - Width: 2.0 m. - Length of roll: 20 m: 15 m for 1.8 mm thick membrane. - Weight:
Fleece (cushion layer):
|
Product Options | Waterproof membrane: - Colour: Available in standard colours. Other colours may be available, subject to a lead time and minimum order quantities. Accessories:
|
G410-EL Adhered Cold Roof System
G410-EL Adhered Roof System - Sarnavap 500E
G410-EL Ballasted Roof System - Sarnavap 500E & Sarnafil G445-13
G410-EL Green Roof System - Cuspated PUR Foam Drainage Board
G410-ELF Adhered Cold Roof System
G410-ELF Adhered Roof System - Sarnavap 500E
Sarnafil G410-EL FSA
Sarnafil S327-EL
Sarnafil TG76 Felt
Sarnafil TG76 Felt Adhered Cold Roof System