RX 561 Top Coat

RX 561 Top Coat

Fassa UK Ltd Third party certifications:
  • QA Certificate

    QA Certificate

    Certificate type

  • BBA Agrément Certificate

    BBA Agrément Certificate

    Certificate type

Rustic, acrylic siloxane finishing coat plaster.

Jump to:
+44 (0)1684 218305 www.fassabortolo.com

Application

Used as a coating for decorating and protecting exterior facades, on:

  • Lime-cement base coat plaster.
  • Skim coats reinforced with alkali-resistant fibreglass reinforcing mesh.
  • The FASSATHERM External Thermal Insulation Composite System.

Consult manufacturer's literature for details on recommended substrate preparation and mixing instructions.

Description

Rustic, acrylic siloxane finishing coat plaster. Composed of acrylic copolymers, polysiloxanes in aqueous emulsion, graded aggregate and titanium dioxide.

Features and benefits:

  • Provides a high level of protection against the growth of algae and mould.
  • Applicable with a trowel.
  • Manufactured in accordance with EN 15824.

Applications:

Used as a coating for decorating and protecting exterior facades, on:

  • Lime-cement base coat plaster.
  • Skim coats reinforced with alkali-resistant fibreglass reinforcing mesh.
  • The FASSATHERM External Thermal Insulation Composite System.

Consult manufacturer's literature for details on recommended substrate preparation and mixing instructions.

General information

Uniclass 2015

Pr_35_31_64_32 Finish plastersPrimary

CAWS

M20/240 One coat proprietary plaster

M20/47 One coat proprietary plaster

Product range

Plastering and rendering

Specification data - Finish plasters

Product Reference

RX 561 Top Coat

Colour

Consult manufacturer and insert requirements.

Version

0

0

Standard product features

Technical characteristics:

  • Specific weight: 1.85 kg/L (approximately).
  • Mixing water required: Up to 2%.
  • Water vapour permeability (to EN 15824): Class V2 (medium).
  • Liquid water absorption (to EN 15824): Class W3 (low).
  • Adhesion (to EN 15824): >0.3 MPa.
  • Thermal conductivity (to EN 15824): λ = 0.74 W/m∙K.
  • Reaction to fire (to EN 15824): A2-s1,d0.
  • VOC content (to 2004/42/EC): <40 g/L.

Literature

Fassatherm

Fassatherm

Fassa Bortolo Plaster & Render System

Fassa Bortolo Plaster & Render System

Third party certifications

  • ETA: Certificate: 07/0280 and 09/0282 and 13/0532 and 16/0932
  • DoP: Certificate: 561-CPR-14-07
  • Certificate: 14/5091