NBS Source
I'm a manufacturer

Rooflight - Ridgelight - Dual Pitched

Verified by manufacturer 6 months ago

Lonsdale Patent Glazing & Rooflights Third party certifications:
  • BRE Certificate

    BRE Certificate

    Certificate type

  • ISO 9001 Quality Management

    Certificate type

Self-supporting dual pitched rooflight

Jump to:
+44 (0)20 8801 4221 Website

Application

Suitable for commercial, public, heritage, listed building, historic, museums, galleries, offices, universities, residential, schools, colleges, atriums and domestic buildings.

Description

TG50 System

  • Thermally broken 50 mm wide aluminium sloped glazing system suitable for commercial, public and domestic buildings.
  • Outstanding air-tightness and weathering performance independently certified.
  • Superior overlapping drainage channels and thermally broken head and eaves aluminium transoms for enhanced thermal efficiency. 
  • Suitable for double or triple insulating glass units.
  • Tested to CWCT TN66-67 and classified Class 2 Non-Fragile. May be deemed to comply with CWCT TN92 when used with recommended glass specifications.
  • Opening ventilation available for natural or smoke.
  • Designed to conform with the requirements of BS 5516 2004 Parts 1 & 2 for the design and installation of sloping and vertical patent glazing when installed within the manufacturers recommendations.
  • Variable pitch down to minimum 5 degrees.
  • Wide centres and long spans means less metal and more daylight.
  • Materials are supplied mill finish as standard or may be polyester powder coated to standard RAL or BS colours to BS 6496.


ThermGard ALM100

A neat 40 mm wide box bar design, ThermGard provides a cost-effective alternative to more expensive sloped curtain walling systems without sacrificing aesthetics. Various slim-line box rafters are available to suit small or large spans. Alternatively the carrier rail may be mounted on top of continuous timber rafters – see our ThermGard-R glazing bars. A continuous screw on pressure plate with gaskets provides outstanding glass retention and a choice of decorative external covers are available to provide either contemporary glass roof appearance or a more traditional heritage style for roof lanterns on period buildings.

General information

Color

Silver

Clear

Guidance for specification option:

Infill.

Other

Guidance for specification option:

Polyester powder coated frame to any RAL or BS colour.

Finish

Glazed

Mill

Powder-coated

Material

Aluminium

Stainless steel

Steel

PVC

Lead

Show more

Shape

Rectangle

Length

Bespoke

Width

Bespoke

Height

Bespoke

Uniclass

Pr_30_59_72_31 Framed rooflightsPrimary

CAWS

H10/115 Patent glazing

L10/45 Rooflights

L10/460 Rooflights

Specification data - Framed rooflights

Form

Flat.

Size

Guidance for specification option:

Consult manufacturer and insert requirements.

Product performance

-

Fire performance

-

Fire resistance

External fire exposure: Class AA.

Guidance for specification option:

To BS 476.

Reaction to fire

Surface spread of flame: Class 1.

Frame

-

Material

Extruded aluminium alloy, 6063-T6.

Finish

-

Coating

Mill finish.

Guidance for specification option:

Standard.

Polyester powder-coated.

Colour

RAL.

Guidance for specification option:

Polyester powder coated: Insert RAL or BS colour code.

Glazing or infill

-

Type

Double glazed, heat soak test (HST) toughened clear glass (laminated softcoat glass).

Guidance for specification option:

Thermal transmittance (U-value): 1.2 W/m²·K.

Double glazed, heat soak test (HST) toughened neutral solar control glass 70/30 (laminated clear glass).

Guidance for specification option:

Thermal transmittance (U-value): 1.0 W/m²·K.

Triple glazed, heat soak test (HST) toughened neutral solar control glass 70/30 (laminated softcoat, clear glass).

Guidance for specification option:

Thermal transmittance (U-value): 0.6 W/m²·K.

Manufacturer guidance

  • Other infills may be incorporated; suitable to receive 24–46 mm double or triple glazing and polycarbonates.
  • Photo voltaics, composite panels, glass reinforced plastic (GRP) and solar thermal panels can also be incorporated on request (consult manufacturer for details).

Construction

Double skin.

Triple skin.

Colour

Clear.

Operation

-

Type

Manual.

Design

Guidance for specification option:

Insert drawing/ reference.

Box bar

Box bar 2.

Box bar 3.

Box bar 4.

Manufacturer guidance

Consult manufacturer for further details.

Combustibility

Non-combustible.

Non-fragility rating

Required.

Guidance for specification option:

  • Tested to CWCT TN66-67, and classified Class 2 non-fragile.
  • May be compliant with CWCT TN92 when used with recommended glass specifications.

Not required.

Flashings

Aluminium.

Lead.

PitchAngle

5° (minimum).

Air permeability

0.71 m³/h.m² at 600 Pa, Class 4.

Guidance for specification option:

To BS EN 12207: 2016.

Weather performance

Weather-tight to Class E1650.

Guidance for specification option:

To BS EN 12208.

Capping

Extruded aluminium alloy, 6063-T6.

Fittings

Extruded aluminium alloy, 6063-T6.

Fasteners

Stainless steel, grade A2.

Pressure plate

PVC.

Manufacturer guidance

Co-extruded.

Thermal break

PVC.

Manufacturer guidance

Co-extruded thermal barrier.

Gaskets

PVC.

Sustainability data

Contains Red List materials

No

Country of material origin

Europe

Country of product manufacture

United Kingdom

Recyclability

Approximately 85% of the product is aluminium which 100% recyclable, remaining 15% is gaskets and thermal liners.

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

35 %

Third party certifications

BRE Certificate

BRE Certificate

Air Permeability Test BS EN 1026

BRE Certificate

BRE Certificate

Watertightness Test BS EN 1027

ISO 9001 Quality Management

ISO 9001 Quality Management

ISO 9001

Literature

TG50 System - Intermediate transom details

TG50 System - Intermediate transom details

TG50 System - Transom drainage details

TG50 System - Transom drainage details

TG50 System - Thermally broken transom assembly details

TG50 System - Thermally broken transom assembly details

TG50 Data Sheet

TG50 Data Sheet

Case studies

Ridgelight for McCarty & Stone

Ridgelight for McCarty & Stone

Similar products from Lonsdale Patent Glazing & Rooflights

Glazing Bar System for Timber Rafters - 50 mm & 40 mm wide

Glazing Bar System for Timber Rafters - 50 mm & 40 mm wide

Patent Glazing - Traditional

Patent Glazing - Traditional

Rooflight - Northlight & Longlights - For Continuous Strip Glazing

Rooflight - Northlight & Longlights - For Continuous Strip Glazing