NBS Source
I'm a manufacturer
Compare variants

Roof Environmental Ventilation Collar

Verified by manufacturer 5 months ago

RVC-R 46.110.110

Sertus Variant:

An environmental ventilation collar designed to be installed below any smoke and heat ventilation unit.

Jump to:
+44 (0) 1483 269999 Website

Application

For installation under any type of smoke and heat ventilation unit.

Description

Roof Vent Collar – Residential (RVC-R) is an environmental ventilation collar designed to be installed below any smoke and heat ventilation unit. It enables the environmental ventilation to continue to operate in any weather.


It comprises an aluminium upstand which may be insulated or uninsulated and two side flaps which drive open and closed by a single 24V DC actuator.


The flaps are centre pivot with brush seals and are protected by a weather cowl which enables environmental ventilation with no rain ingress in virtually any weather.


The base flange is available with a drip edge detail to install to a builder's upstand or to fit a profile roof or patent glazed system.

The unit is available in four heights.


Features and benefits:

  • May be installed under virtually any type of smoke and heat ventilation unit.
  • Ventilation flaps can be open in virtually any weather.
  • RVC-R are available with uninsulated or insulated upstands.
  • Operated by 24 V d.c. actuators which can be controlled to open on environment ventilation and close on fire signal.
  • Wide range of sizes and heights available giving a choice of ventilation areas.
  • Available in mill finish aluminium or polyester powder-coated to any RAL colour.
  • Base flange is supplied to install to builders upstand or into profile roofs or patent glazed systems.


General information

Color

Other

Finish

Mill

Powder-coated

Material

Aluminium

Shape

Square

Rectangle

Length

1100 mm

2200 mm

Width

1100 mm

Height

460 mm

560 mm

770 mm

850 mm

Warranty description

Five year

Guidance for specification option:

Vent collar unit.

Two year

Guidance for specification option:

Electrical actuator and opening mechanism.

Uniclass

Pr_30_59_29_75 Roof ventilator unitPrimary

CAWS

L10/47 Roof ventilators

L10/490 Roof ventilators

Specification data - Roof ventilator unit

Arrangement

Installed below smoke and heat ventilation unit.

Ventilator type

Square.

Size

1100 x 1100 mm.

Outer facing

Aluminium.

External finish

Mill finish.

Polyester powder-coated.

Colour

Mill finish.

Standard RAL.

Guidance for specification option:

For powder-coating. Insert requirements.

Operation

-

Type

Electrically powered actuator.

Electrical supply

24 V d.c..

Accessories

Type F1 flange - to builders upstand.

Type F2 flange - to profile roof.

Type F3 flange - to patent glazing system.

Height

460 mm.

Initiation

Automatic, power open power close.

Guidance for specification option:

The actuators can be controlled to open on environment ventilation and close on fire signal.

Frame

Aluminium.

Louvres

Aluminium.

BIM objects

Platform Compatible Version
Revit
-

1

Literature

Sertus RVC-R Installation Guide

Sertus RVC-R Installation Guide

Sertus RVC-R Operation & Maintenance Manual

Sertus RVC-R Operation & Maintenance Manual

Sertus RVC-R Technical Data Sheet

Sertus RVC-R Technical Data Sheet

Sertus RVC-R Warranty

Sertus RVC-R Warranty

Case studies