Verified by manufacturer 9 months ago
SecuriCharge 1 x 7.4kW Type 2 Socket - Black (ROLEC0111B)
A heavy-duty, intelligent EV charging unit for workplaces and car parks.
Suitable for workplaces, car parks, warehouses and public locations.
SecuriCharge is a wall-mounted EV charge point for workplaces and car parks. Featuring 1 x universal charging socket (up to 7.4 kW or up to 22 kW) its heavy-duty and vandal-resistant features, make it a particularly suitable solution for exposed locations.
This OCPP-compliant unit can offer a simple plug-and-charge or pay-to-charge solution via the EV driver’s smartphone and/ or RFID card/ fob through any chosen OCPP back-office management system.
This EV charger supports dynamic load balancing and is equipped with PME fault detection, so there is no requirement for an earth rod, reducing installation costs.
Features and benefits:
Color | Black White Grey |
Finish | Powder-coated |
Material | Steel |
Shape | Rectangle |
Length | 575 mm |
Width | 320 mm |
Height | 155 mm |
Warranty description | Three year |
Uniclass | |
CAWS | V90/590 Equipment |
Product range |
Standards | To EN IEC 61851-1:2019, EN 61851-22:2002. |
Charging mode | 3. |
Input voltage | 230 V a.c. single-phase. |
Input current | 32 A. |
Rated frequency | 50/60 Hz. |
Power output | 7.4 kW. |
Outlet type | Single, Type 2 socket, to IEC 62196 series. |
Mounting | Wall-mounted.Post-mounted. |
Impact protection (minimum) | IK10. |
Ingress protection (minimum) | Enclosure IP54, socket IP54. |
Circuit protection | AC overload and fault current protection – 40 A 30 mA Type A RCBO (per socket). |
Accessories | RFID0010 RFID card.RFID0020 RFID fob.EVFP0060 Mounting post to fit 1x SecuriCharge unit.EVFP0070 Mounting post to fit 2x SecuriCharge units.EVCB0020 Root mount protection barrier – 48 mm.EVCB0040 Surface mount protection barrier – 48 mm.EVPS0010 EV parking sign – A4 landscape.Guidance for specification option: Other sizes are available. EVPP0100 5 m 32 A Type 2 to Type 2 charging cable.EVPP0107 10 m 32 A Type 2 to Type 2 charging cable.EVPP0105 5 m 32 A Three phase Type 2 to Type 2 charging cable.EVPP0108 10 m 32 A Three phase Type 2 to Type 2 charging cable.Guidance for specification option: Other cables are available, including Type 1 options. EVRS0030 Remote wall mount for Type 2 charge plug holster.ACSR0125 100 A up to 35 mm² screened CT clamp with 10 m cable. |
Operating temperature range | -30°C to +50°C. |
Colour | Black. |
Communications | 4G LTE Cat-1. |
Interfaces | Mobile app. |
Integral accessories | Integrated Class 1 MID compliant metering. |
Country of product manufacture | United Kingdom |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
- | 1 | |
- | 1 |