You are viewing content for United Kingdom.
Choose a country to see content for your location. Changing region will navigate you to the homepage.
Verified by manufacturer 10 days ago
50 mm
EPD
Certificate type
Extruded polystyrene (XPS) thermal insulation designed for high loadbearing floors.
Provides a suitable thermal insulation with its closed cell structure is a solution for heavy-duty inverted roofs and floor structures.
Ravatherm XPS X 500 SL is used on heavy-duty inverted roofs, floor structures and load-bearing base slabs. The board has low water absorption (<0.7% according to EN 12087).
Available in 50mm, 75mm, and 10mm thicknesses.
500kPa compressive strength (according to EN 826)
180kPa compressive creep (2% deformation after 50 years according to EN 1606)
Color | Grey |
Finish | Smooth Guidance for specification option: Smooth surface skin (extrusion skin). |
Material | Polystyrene Guidance for specification option: Homogeneous, closed-cell material structure comprised of extruded polystyrene (XPS), a rigid form of insulation. |
Shape | Rectangle |
Length | 1250 mm |
Width | 600 mm |
Height | 50 mm 75 mm 100 mm |
Uniclass | |
CAWS | E20/200 Proprietary underslab insulation E20/30 Underslab insulation K11/115 Battened plywood floating floor K11/125 Battened particleboard floating floor K11/135 Battened oriented strand board floating floor K11/145 Battened cement-bonded particleboard floating floor K11/20 Battened particleboard floating floor K11/215 Plywood floating floor K11/225 Particleboard floating floor K11/235 Oriented strand board floating floor K11/245 Cement bonded particleboard floating floor K11/25 Particleboard floating floor K20/150 Battened timber board floating floor K20/20 Battened timber board floating floor K21/120 Battened wood flooring K21/130 Battened wood floating floor K21/30 Wood lining on battens M10/290 Floating construction M10/40 Floating construction M13/260 Floating construction M13/40 Floating construction |
SKU Code | XPS X 500 SL |
Classification data | |
Standard | To BS EN 13164. |
Fire performance | Euroclass E. Guidance for specification option: Products contain an ecologically safe flame-retardant additive. Manufacturer guidanceTo BS EN 13501-1. |
Compressive strength (minimum) at 10% compression | 500 kPa. Guidance for specification option: To EN 826. To plan the reinforcement steel requirements of floor slab used as a load-distribution structure over the thermal insulation layer, please consult a structural engineer. |
Thermal conductivity (maximum) | 0.031 W/m·K. Guidance for specification option: To EN 13164. |
Thickness | 50 mm. |
Face size (length x width) | 1250 x 600 mm. Guidance for specification option: The maximum installation depth of the thermal insulation is determined by the load: the horizontal pressure must not exceed the compressive strength of the boards, taking into account the value of the permanent load. |
Facing | Smooth. Guidance for specification option: Smooth surface skin (extrusion skin). PE film separating and sliding layer between the thermal insulation and the concrete screed for installation on floor applications. |
Edges | Ship lap. Guidance for specification option: A grooved edge allowing boards to overlap, minimizing gaps. |
Compressive creep (design load) maximum 2% deflection after 50 years | 180 kPa. Guidance for specification option: To EN 1606. |
TemperatureRange | -50°C to +75°C maximum. Guidance for specification option: Provides the permanent application temperature of Ravatherm XPS X products. At higher temperatures, the boards will start to soften and suffer permanent deformation. |
Thermal resistance (R-value) | 1.60. Manufacturer guidance(Rd m2 .K/W) |
Country of product manufacture | United Kingdom |
Material | Polystyrene Guidance for specification option: Homogeneous, closed-cell material structure comprised of extruded polystyrene (XPS), a rigid form of insulation. |
| Carbon dioxide equivalent | |
Carbon dioxide equivalent, as defined in BS EN 15804 Certified | |
Stage Normalised unit (kg CO₂ eq/kg) Declared unit (kg CO₂ eq/kg) Stage:A1–A3 ('Production stage') Normalised unit : 2.77 (kg CO₂ eq/kg) Declared unit : 2.77 Lower emissions | |
Recyclability | 100% |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | Manufacturer guidanceRavatherm XPS X uses carbon dioxide as a blowing agent, which gives it an ozone-depleting potential (ODP) of zero and a Global Warming Potential (GWP) of less than five. |
This BIM object has been authored to meet the requirements of the
Find out more about the
| Platform | Compatible | Version |
|---|---|---|
| - | 7 | |
| - | 7 |