Rada 222-T3 DK

Rada 222-T3 DK

Rada Third party certifications:
  • BSI Kitemark

    BSI Kitemark

    Certificate type

  • QA Certificate

    QA Certificate

    Certificate type

A ¾” thermostatic mixing valve incorporating Radatherm service-free cartridge, check valves and strainers.

Jump to:
+44 (0)844 571 1777 www.radacontrols.com

Description

A concealed thermostatic mixing valve, designed for use with a separate outlet flow control such as a tap.

General information

Features

Radatherm cartridge, Check valves, Strainers

Finish

Nickel plated

Size

0.0

WarrantyDescription

Two years parts and labour as standard; Extended to five years parts and labour if commissioned by Rada. UK only

Uniclass 2015

Pr_40_20_87_81 Shower thermostatic water supply setsPrimary

CAWS

N13/35 Baths

N13/355 Baths

S90/680 Thermostatic mixing valves

S90/680 Thermostatic mixing valves

Specification data - Shower thermostatic water supply sets

Product Reference

Rada 222-T3 Thermostatic Mixing Valve (1.0.407.07.3)

Standard product features

A ¾" thermostatic mixing valve incorporating a Radatherm service-free cartridge, check valves and strainers.

Mixers are supplied with ¾" flat faced union connectors terminating in 22 mm compression connections.

Operation:

Designed to be concealed in a duct or cupboard and used with a separate outlet in bathing facilities.

Connections:

  • Inlet and outlet: ¾" flat faced male union.
  • Note: 2 elbows and 1 straight union connectors are supplied, terminating in 22 mm compression connections.
  • Standard connections are hot (left), right (cold).

Pressure/ Flow rates:

  • Minimum dynamic supply pressure: 0.15 bar.
  • Minimum flow rate: 3 litres/minute at mid blend.
  • Maximum flow rate: 40 litres/minute at mid blend.
  • Maximum pressure loss ratio: 10:1 (in favour of either supply).
  • Maximum dynamic supply pressure: 5 bar.
  • Maximum static pressure: 10 bar.

Note: Both hot and cold pressures should be nominally equal.

Temperature range:

  • Factory pre-set maximum outlet temperature: 43°C.
  • Minimum temperature differential blend to either supply: 12°C.
  • Optimum temperature control range: 30–50°C.
  • Minimum cold water temperature: 1°C.
  • Maximum hot water temperature: 85°C.

Note: The mixing valve can accept temporary temperature excursions above 85°C without damage, however, operation at such elevated temperatures is not recommended. For safety reasons it is recommended that the hot water storage temperature is maintained at between 60°C and 65°C in ablutionary applications.

Materials:

  • Body: DZR brass nickel plated.
  • Locking shroud: White engineering plastic.

Digital objects

Platform Compatible Version Certified to
Revit

Revit 2016

4

1.3
IFC
-

5

1.3
AECOsim
-

1.0

1.0

Download now from NBS National BIM Library

Literature

Rada Healthcare Product Selector

Rada Healthcare Product Selector

Third party certifications

  • BS 7942 : For high and low pressure use on baths
  • BS EN 1111
  • BS EN 1287
  • Buildcert: Certificate - ETC/15/0597 : Buildcert TMV3 Thermostatic Mixing Valve Scheme approved
  • Water Regulations Advisory Scheme (WRAS) approved

Similar products from Rada

Meynell Bonus

Meynell Bonus

Rada 120 Mono-Control System

Rada 120 Mono-Control System

Rada 129 Mono-Control System

Rada 129 Mono-Control System

Rada 215-t3 bc Thermostatic Mixing Valve

Rada 215-t3 bc Thermostatic Mixing Valve

Rada 215-t3 c Thermostatic Mixing Valve

Rada 215-t3 c Thermostatic Mixing Valve

Rada 215-t3 dk Thermostatic Mixing Valve

Rada 215-t3 dk Thermostatic Mixing Valve

Rada 320 - C Thermostatic Mixing Valve

Rada 320 - C Thermostatic Mixing Valve

Rada 320 IC Thermostatic Mixing Valve

Rada 320 IC Thermostatic Mixing Valve

Rada 32RMX Temperature Controller

Rada 32RMX Temperature Controller

Rada 425 IC Thermostatic Mixing Valve

Rada 425 IC Thermostatic Mixing Valve