PURE100 Single-offset Glazed Panel Partition System

Verified by manufacturer 11 days ago

35 dB Rw | 10 mm Toughened Glass

Planet Variant:
Third party certifications:
  • EPD

    EPD

    Certificate type

A 100 mm wide framed, single-offset glazed partition system with frameless glass joints.

Jump to:
BOS
+44 (0)1444 247933 Website

Application

All sectors: Commercial: Education; Healthcare; MoD; Airport; Rail; Industrial; Hospitality; Residential; Public.

Consult manufacturer for further details.

Description

A 100 mm wide framed, single-offset glazed partition system with frameless glass joints.


Features and benefits:

  • Demountable partitioning system offers unparalleled acoustic performance and versatility.
  • Acoustic performance of up to 40 dB (Rw).
  • The 100 mm wide framework platform offers countless options including frameless glazing, either single-offset or double-glazed, solid division walls or even modular paneled glazing.
  • All configurations utilize the same aluminium framing profiles for simple future reconfiguration.


Please note that acoustic, fire rated and structural certification and support for Planet products and systems is available on a project-specific basis. Please contact the specification team directly for further information.

General information

Color

Other

Guidance for specification option:

Polyester powder-coated or anodized.

Silver

Guidance for specification option:

Polished or linished.

Finish

Polished

Anodized

Guidance for specification option:

Etched and anodized.

Powder-coated

Material

Aluminium

Guidance for specification option:

6063 T6.

Glass

Shape

Rectangle

Other

Manufacturer guidance

To suit project requirements; consult manufacturer for further details.

Length

Bespoke

Width

100 mm

Height

Bespoke

Warranty description

Guidance for specification option:

Dealt with on a project specific basis as part of the O&M process; consult manufacturer for details.

Uniclass

Pr_25_71_57_60 Partition panelsPrimary
Ss_25_12_65_65 Panel partition systems

CAWS

K30/130 Relocatable partition system

K30/10 Relocatable partition system

Product range

Pure Glazed Partitions / PURE100

Specification data - Partition panels

Third-party certification

ISO 9001-UKAS (Quality); ISO 14001-UKAS (Environmental); Constructionline-Gold; Acclaim (SIPP); Achilles (Building confidence, SIPP); EPD - material accreditation & compliance; FIS Member; Considerate Construction; FORS Bronze; Build Profile.

Guidance for specification option:

EPD - material accreditation & compliance: Consult manufacturer for details (glass, PPC, aluminium, timber, ironmongery, waste, adhesive and more).

Unit size

-

Thickness

100 mm.

Partition height (nominal)

-

Manufacturer guidance

Insert requirements. For partitions over 3000 mm high, consult with manufacturer.

Width (nominal)

-

Manufacturer guidance

Insert requirements. For partitions over 1200 mm wide, consult with manufacturer.

Deflection allowance (maximum)

-

Head

No deflection; 27 mm deep x 100 mm wide channel.

±15 mm deflection; 60 mm deep x 100 mm wide channel.

±25 mm deflection; 90 mm deep x 100 mm wide channel.

±40 mm deflection; 146 mm deep x 100 mm wide channel.

Floor

-

Manufacturer guidance

Consult with manufacturer for system weight.

Verticals

27 mm deep x 100 mm wide channel.

Panel partition type

Frameless glass.

Framing, fixing points and joints

27 mm deep x 100 mm wide base and abutment tracks.

Manufacturer guidance

Corners: glass to glass joints.

Joint treatment

-

Type

Butt jointed glazing.

Single offset glazed.

Vertex PVC translucent cross dry joint.

Guidance for specification option:

Junctions and corners; 1.5 mm visible, glass edge preparation required.

Linea PET-G translucent dry joint.

Guidance for specification option:

Junctions and corners; 5 mm visible, glass edge preparation required.

Linea PET-G black dry joint.

Guidance for specification option:

Junctions and corners; 5 mm visible, glass edge preparation required.

Nova SAA / PPC aluminium dry joint.

Guidance for specification option:

Junctions and corners; 13 mm visible, glass edge preparation required.

Solar PVC-U translucent ‘H’ joint.

Guidance for specification option:

Junctions and corners; 12 mm visible.

Acrylic glazing tape, translucent.

Guidance for specification option:

Junctions and corners; 2 mm visible.

Finish and colour

As Framing, junctions, corners.

Glazed panels

-

Type

Single-offset, 10 mm toughened glass.

Guidance for specification option:

Additional manufacturer options;

  • Annealed laminate.
  • Annealed acoustic laminate.
  • Toughened - heat soaked.
  • LCD switchable.
  • Low iron.


Consult manufacturer for details.

Manufacturer guidance

Consult manufacturer to ensure compliance with test/ assessment data.

Integral blinds

n/a.

Guidance for specification option:

Not suitable for this system.

Additional features

None.

Double glazed/ boarded tech panel to incorporate room booking systems, access control and other electronics.

Door arrangement

-

Type

IsoClear frameless leaf in door frame, single leaf, single action.

IsoClear frameless leaf in door frame, unequal leaves, single action.

IsoClear frameless leaf in door frame, double leaves, single action.

IsoTec micro framed leaf in door frame, single leaf, single action.

IsoTec micro framed leaf in door frame, unequal leaves, single action.

IsoTec micro framed leaf in door frame, double leaves, single action.

IsoPro framed leaf in door frame, single leaf, single action.

IsoPro framed leaf in door frame, unequal leaves, single action.

IsoPro framed leaf in door frame, double leaves, single action.

Door frames

Frameless (no door frame), door frame.

Planet A131 aluminium door frame, with single leaf set.

Planet A131 aluminium door frame, with unequal leaf doors.

Planet A131 aluminium door frame, with double doors.

Door panels

-

Type

Planet IsoClear 12 mm door leaf – non-acoustic.

Guidance for specification option:

Suitable for use in:

  • Planet aluminium door frame, with single leaf set.
  • Planet aluminium door frame, with unequal leaf doorset.
  • Planet aluminium door frame, with double leaf doorset.

Planet IsoClear 12 mm door leaf – 34 dB Rw.

Guidance for specification option:

Suitable for use in Planet aluminium door frame, with single leaf set only.

Planet IsoTec 12 mm door leaf – non-acoustic.

Guidance for specification option:

Suitable for use in:

  • Planet aluminium door frame, with single leaf set.
  • Planet aluminium door frame, with double leaf doorset.

Planet IsoTec 12 mm door leaf – 34 dB Rw.

Guidance for specification option:

Suitable for use in Planet aluminium door frame, with single leaf set only.

Planet IsoPro, single glazed metal framed door leaf – 34 dB Rw.

Guidance for specification option:

Suitable for use in Planet aluminium door frame, with single leaf set only.

Planet IsoPro, double glazed metal framed door leaf – 34 dB Rw.

Guidance for specification option:

Suitable for use in Planet aluminium door frame, with single leaf set only.

Planet IsoPro, single glazed metal framed door leaf – 36 dB Rw.

Guidance for specification option:

Suitable for use in Planet aluminium door frame, with single leaf set only.

Planet IsoPro, double glazed metal framed door leaf – 39 dB Rw.

Guidance for specification option:

Suitable for use in Planet aluminium door frame, with single leaf set only.

Planet IsoPro, double glazed metal framed door leaf – 42 dB Rw.

Guidance for specification option:

Suitable for use in Planet aluminium door frame, with single leaf set only.

Timber 44 mm leaf on hinges – 29 dB on to carpet.

Guidance for specification option:

Suitable for use in Planet aluminium door frame, with single leaf set only.

Timber 44 mm leaf on hinges – 32 dB on to carpet.

Guidance for specification option:

Suitable for use in Planet aluminium door frame, with single leaf set only.

Timber 54 mm rebated leaf on hinges – 33 dB on to carpet.

Guidance for specification option:

Suitable for use in Planet aluminium door frame, with single leaf set only.

Timber 54 mm rebated leaf on hinges – 35 dB on to carpet.

Guidance for specification option:

Suitable for use in Planet aluminium door frame, with single leaf set only.

Timber 54 mm rebated leaf on hinges – 38 dB on to solid floor.

Guidance for specification option:

Suitable for use in Planet aluminium door frame, with single leaf set only.

Timber 54 mm rebated leaf on hinges – 40 dB on to aluminium threshold.

Guidance for specification option:

Suitable for use in Planet aluminium door frame, with single leaf set only.

Planet IsoPro, double glazed metal framed door leaf (non-rebated) – 31 dB Rw.

Guidance for specification option:

Suitable for use in:

  • Planet aluminium door frame, with unequal leaf doorset.
  • Planet aluminium door frame, with double leaf doorset.

Planet IsoPro, double glazed metal framed door leaf (rebated) – 33 dB.

Guidance for specification option:

Suitable for use in Planet aluminium door frame, with unequal leaf doorset only.

Planet IsoPro, double glazed metal framed door leaf (rebated) – 35 dB.

Guidance for specification option:

Suitable for use in Planet aluminium door frame, with unequal leaf doorset only.

Planet IsoPro, double glazed metal framed door leaf (rebated) – 36 dB.

Guidance for specification option:

Suitable for use in Planet aluminium door frame, with unequal leaf doorset only.

Planet IsoPro, single glazed metal framed door leaf (non-rebated) – non-acoustic.

Guidance for specification option:

Suitable for use in Planet aluminium door frame, with double leaf doorset only.

Timber 44 mm leaf on hinges – non-acoustic.

Guidance for specification option:

Suitable for use in Planet aluminium door frame, with double leaf doorset only.

Timber 54 mm rebated leaf on hinges – non-acoustic.

Guidance for specification option:

Suitable for use in Planet aluminium door frame, with double leaf doorset only.

Vision panels

Not required.

Required.

Guidance for specification option:

Available with timber door leaves only; consult manufacturer for details and insert requirements.

Ceiling

-

Type

-

Manufacturer guidance

Consult manufacturer for interface detail and insert requirements.

Method of support

-

Manufacturer guidance

Consult manufacturer for support detail and insert requirements.

Perimeters, skirtings, sills

27 mm deep x 100 mm wide aluminium channel.

Hardware

-

Manufacturer guidance

See appropriate door specification for applicable ironmongery options.

Seals

Clear perimeter compression seals.

Black perimeter compression seals.

Cable management and outlets

Not required.

As Glazed panels - Additional features.

Guidance for specification option:

Double glazed/ boarded Tech Panel to incorporate room booking systems, access control and other electronics.

Other features

-

Manufacturer guidance

Consult manufacturer and insert requirements or leave blank.

Product Reference

p100 Single-offset Glazed Panel Partition System

Manifestation

Allowance of 2 nr rows 50 mm dots or square (minimum) Opal Frost.

Guidance for specification option:

Insert requirements.

Artwork and custom manifestation to client design.

Guidance for specification option:

Insert requirements.

StrengthGrade

-

Manufacturer guidance

Consult with the manufacturer to ensure the system complies with current regulations BS 5234:1992 non load-bearing screens not protecting a change in adjacent floor level of >380 mm.


For glass load resistance criteria;

  • BS 5234 not applied to “all glass partition screens”.
  • Nominal line load criteria of “short-term impact load” utilised.
  • 0.36 kN/m applied as linear load at 1100 mm above FFL.
  • Glass deflection limited to L/65 or 25 mm, whichever is less under load.
  • Maximum deflection and stress in accordance with the glass performance requirements of EN 572/ EN 12150/ EN 12543/ EN 14179 (where heat soaked).


Building regulations Part N (BS 6262 & BS EN 12600) + InsStucEng publication “structural use of glass in buildings” insert as required:

  • 0.36 kN/m (default load).
  • 0.74 kN/m.
  • 1.5 kN/m.


BS 6180:2011 barriers in and about buildings for Atria or protected change in adjacent floor level of >380 mm.

Horizontal uniformly distributed line load 1100 mm above FFL (glass deflection limited to L/65 or 25 mm, whichever is less relative to glass fixings).

Structural glass based on line-load and attendant UDL + point load, insert as required:

  • 0.74 kN/m.
  • 1.5 kN/m.
  • 3.0 kN/m.

Acoustic performance

35 dB Rw.

Manufacturer guidance

To comply to EN ISO 10140-2 and ISO 717-1: Acoustics vary according to framework/glazing options subject to further design development.

Partition

Frameless glass - offset single glazed.

Fasteners

To manufacturer's specification, type, length and frequency to suit substrates.

Joint treatment

Butt jointed glazing.

System accessories

-

Manufacturer guidance

Tech panels, access control - consult with manufacturer for details.

Samples required

-

Manufacturer guidance

Consult with manufacturer.

Finish/ Colour

Polyester powder-coated, RAL.

Guidance for specification option:

Insert colour requirement.

Polished and chemically brightened.

Linished and chemically brightened.

Etched and anodized.

Guidance for specification option:

Insert requirement.

Sustainability data

Contains Red List materials

No

Guidance for specification option:

No substance on the “Candidate List of Substances of Very High Concern for authorisation” derived under REACH is present either above the limits for registration with the European Chemicals Agency or in excess of 0.1% weight by weight of the product.

Country of material origin

United Kingdom

Country of product manufacture

United Kingdom

Material

Aluminium

Guidance for specification option:

6063 T6.

Glass

Embodied carbon

A1-A3 (production stage) as defined in BS EN 15804

71.2 kg CO₂ eq/m²

Guidance for specification option:

There will be slight variances in embodied carbon if different glass thicknesses, etc, are used. These embodied carbon figures are for 1 m² of each type of partition – modules A1-A3 including biogenic carbon.


The EPD for the single glazed partition systems is based on powder-coated aluminium-framed single-glazed partition systems using 12.8 mm laminated glass, without a door.

Recyclability

100%

Guidance for specification option:

Aluminium and glass.

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

-

Manufacturer guidance

17–28% for glass.

70% for aluminium.

Third party certifications

BIM objects

BOS

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.

Find out more about the NBS BIM Object Standard.

Platform Compatible Version
Revit
-

2

IFC
-

1

Third party certifications

EPD

EPD

Planet Single Glazed Partition System EPD

Literature

Planet Partitioning Product Guide

Planet Partitioning Product Guide

PURE100 Glazed Partition System Data Sheet

PURE100 Glazed Partition System Data Sheet

Case studies

Leading Technology Company

Leading Technology Company