The hands-free interface, used with hands-free tokens, means the token that identifies a user is read from within a pocket or handbag by using Paxton’s wireless technology.

Jump to:
BOS
+44 (0)1273 811011 Website

Application

Installation – Any new or existing P series reader, and KP keypads, can be converted to hands-free by fitting a hands-free interface. The interface requires no external power source and is wired in series between the reader and the control unit. It should be mounted as close to the reader as is possible up to a maximum of 15 m.

 

Operation – Once the interface has been fitted, the hands-free tokens will have a read range of between 0.85–2.5 m. The reader will continue to read regular tokens as usual. If the long read range causes any problems, such as people unlocking the door as they walk past, an entry confirmation button can be fitted. The entry button can be any standard push-to-make device and prevents the door from opening until it has been pressed.

Description

Hands free entry is useful to provide ease of access through doors in warehouses or to provide contactless hygienic access in hospitals and 'clean room' environments. Unlike most hands free solutions available for access control systems, there is a choice from a range of stylish and discreet readers.


Features and benefits:

  • Any new or existing P series reader, and KP keypads, can be converted to hands free by fitting a hands free interface.
  • The interface requires no external power source and is wired in series between the reader and the control unit.
  • The interface should be mounted as close to the reader as is possible up to a maximum of 15 m.

General information

Color

Black

Material

Plastic

Shape

Rectangle

Length

120 mm

Width

120 mm

Height

40 mm

Warranty description

Five year

Uniclass

Ss_75_40_02_11 Card access control systemsPrimary

CAWS

W90/363 Access control units

W90/130 Electronic access control system

Product range

Accessories
Net2

Specification data - Card access control systems

System supplier

Paxton Access Limited.

System type

Networked stand-alone door controller.

Equipment interconnectivity

Wired access control unit linking to readers and ancillary components; wireless data connection between access control units and proximity devices.

Method of authorization

Active proximity devices.

Readers

Proximity card readers.

Controls

Access control units.

Door status monitoring

Door status monitoring devices.

Rewireable installation

Required.

Accessories

Not required.

Net2 hands free keyfob.

Guidance for specification option:

690-222.

Switch2 hands free keyfob - Green, Pack of 10.

Guidance for specification option:

860-010G.

Current

80 mA.

Extension

100 m (Maximum cable extension length between ACU and interface),
15 m (Maximum cable extension length between interface and reader).

Guidance for specification option:

Belden 9540.

Frequency

2.4 GHz.

Operating temperature

-20 to 55°C.

Operating voltage

11–14 V d.c.

Sustainability data

Country of product manufacture

United Kingdom

Material

Plastic

BIM objects

BOS

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.

Find out more about the NBS BIM Object Standard.

Platform Compatible Version
Revit
-

1

IFC
-

1

Literature

Proximity hands-free interface, Plastic housing - instructions

Proximity hands-free interface, Plastic housing - instructions

Similar products from Paxton Access Ltd

Entry - Audio Monitor - Intercom Handset

Entry - Audio Monitor - Intercom Handset

Entry - Premium Monitor - Intercom Handset

Entry - Premium Monitor - Intercom Handset

Entry - Standard Monitor - Intercom Handset

Entry - Standard Monitor - Intercom Handset

Entry - Standard Panel - Intercom Call Station

Entry - Standard Panel - Intercom Call Station

Entry - Touch Panel - Intercom Call Station

Entry - Touch Panel - Intercom Call Station

Entry - VR Panel - Intercom Call Station

Entry - VR Panel - Intercom Call Station

Entry monitor  - Desktop Stand

Entry monitor - Desktop Stand

Net2 Air Bridge

Net2 Air Bridge

Net2 Desktop Reader, USB - Enrolment Reader

Net2 Desktop Reader, USB - Enrolment Reader

Net2 I/O Board 12V 2A PSU, Plastic Cabinet - I/O Module

Net2 I/O Board 12V 2A PSU, Plastic Cabinet - I/O Module