A torch-applied, polymer-modified reinforced bituminous capsheet which is saturated and coated with high quality thermoplastic bitumen and anti-root additives.
Designed for use as a high-performance anti-root capsheet and can be used as the final waterproofing layer for Pro-Living® extensive, intensive and bio-diverse green roof finishes on a variety of Proteus Waterproofing built-up roofing systems (e.g. Torch-Safe and full Torch-On specifications).
The product is compatible with all common bituminous underlay membranes.
Suitable for use on the following substrates:
Appropriate for the following uses:
The product is reinforced with non-woven polyester with glass fibre, a mineral finish on its upper surface, and a torch receivable film on its underside, and is specifically designed for waterproofing structures where the presence of vegetation is expected.
The combination of the reinforcement, the waterproofing mass characteristics and suitable additives with special chemicals ensure resistance against the penetration of roots and aggressive chemicals, such as fertilizers, herbicides, etc. whilst not affecting the life and health of plants. Additives are not leached by water and are resistant to the action of the blowtorch flame used for the application, therefore, the product exerts its function permanently.
Designed for use as a high-performance anti-root capsheet and can be used as the final waterproofing layer for Pro-Living® extensive, intensive and bio-diverse green roof finishes on a variety of Proteus Waterproofing built-up roofing systems (e.g. Torch-Safe and full Torch-On specifications).
The product is compatible with all common bituminous underlay membranes.
Color | Grey |
Finish | Mineral |
Material | Bitumen Polymer Polyester Glass Fibre |
Shape | Rectangle Guidance for specification option: Roll. |
Length | 10000 mm |
Width | 1000 mm |
Height | 5 mm |
Warranty description | 30 year |
Uniclass | |
CAWS | J41/400 Built-up reinforced bitumen waterproof covering J41/110 Built-up reinforced bitumen membrane warm deck roof covering J41/120 Built-up reinforced bitumen membrane inverted roof covering J41/125 Single-layer reinforced bitumen membrane inverted roof covering J41/135 Single-layer reinforced bitumen membrane cold deck roof covering J41/115 Single-layer reinforced bitumen membrane warm deck roof covering J41/130 Built-up reinforced bitumen membrane cold deck roof covering J41/405 Single-layer reinforced bitumen waterproof covering |
SKU Code | FGECSMAR08 |
Classification data | |
Standard | To BS EN 13707. |
Performance characteristics | Reaction to fire to EN 13501-1, Class E. |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | Manufacturer's standard. Guidance for specification option: Consult manufacturer for details. |
Material | |
Carrier material | Non-woven polyester reinforced with glass fibre. |
Bitumen modification | APP treated with special anti-root additive. |
Thickness (minimum) | 5 mm. |
Weight (minimum) | 5.5 kg/m². Guidance for specification option: 44 kg per standard roll. |
Surface finish | |
Top | Mineral granules. |
Underside | Torch receivable film. |
Colour | Grey. |
Roll size | 10 x 1 m. |
Tensile strength | To EN 12311-1, longitudinal 900 N/50mm; transverse 700 N/50mm. Guidance for specification option: +/-20%. |
Elongation at break | To EN 12311-1, longitudinal: 45%; transverse: 45%. |
Impact resistance | To EN 12691, 1250 mm. |
Static load resistance | To EN 12730 Method A, 20 kg. |
Resistance to tearing | To EN 12310-1 (nail shank), 150/150 N. |
Dimensional stability | To EN 1107-1:A, longitudinal/ transverse: +/-0.3%. |
Watertightness | To EN 1928 Method A, 60 kPa. |
Flexibility at low temperature | To EN 1109, -20°C. |
Technical characteristics, other | Straightness to EN 1848-1, 20 mm/10m. Shear resistance to EN 12317-1, longitudinal 500 N/50mm; transverse 500 N/50mm. Resistance to root penetration to EN 13948 FLL Method, Pass. Flow resistance at elevated temperature to EN 1110, 130°C. Flow resistance at elevated temperature after artificial ageing to EN 1296/ EN 1110, 130°C. Adhesion of granules to EN 12039, maximum 30%. |
Contains Red List materials | No |
Material | Bitumen Polymer Polyester Glass Fibre |
Carbon dioxide equivalent | |
Carbon dioxide equivalent, as defined in BS EN 15804 Self-declared | |
Stage Normalised unit (kg CO₂ eq/kg) Declared unit (kg CO₂ eq/unit) Stage:A1–A3 ('Production stage') Normalised unit : Declared unit 0.06 : Lower emissions | |
Recyclability | As part of the roof membrane, product end-of-life management is assumed to be, on average: • 40 % to landfill • 45 % to incineration with energy recovery • 15 % to recycling |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 0 % |
Expected Life | 35 year |
Pro-Vapour Control/Carrier Membrane SA
Proteus Hot Melt® Anti-Root Capsheet - Waterproofing Membrane
Proteus Hot Melt® Capsheet - Waterproofing Membrane
Proteus Pro-Felt® 3mm Plain Underlay - Torch-on Reinforced Bitumen Membrane
Proteus Pro-Felt® Dispersion Underlay - Torch-on Reinforced Bitumen Membrane
Proteus Pro-Felt® Endura AIRdhesive - Bituminous Membrane
Proteus Pro-Felt® Endura AVCL - Bituminous AVCL
Proteus Pro-Felt® Endura Mineral - Bituminous Cap Sheet
Proteus Pro-Felt® Endura SA - Bituminous Cap Sheet
Proteus Pro-Felt® Endura SA AVCL - Bituminous AVCL