Verified by manufacturer 6 months ago
BBA Agrément Certificate
Certificate type
Adhered PVC single-ply membrane water attenuation blue roofing system for warm roof constructions.
Can be laid on roofs designed for slopes with a minimum 1:100 towards the outlet. Suitable for new build and refurbishment applications on flat or pitched roofs. Can be used on concrete roof decking, plywood WBP to BS 5268-2 and BS EN 636-3, profiled galvanized steel deck, roofing Grade OSB to BS EN 300 and profiled aluminium deck.
Water attenuation blue roofing system for new and existing roofs that includes Protan BPX 1.8 mm thick roofing membranes manufactured from PVC with a polyester reinforced core. Installed as exposed roofing, allowing rainwater to accumulate to a predefined maximum level and be stored on the roof for a certain amount of time after rainfall. Water run-off is then gradually permitted into the into the building's drainage system before entering the drainage network. This avoids water overloading, which can result in flooding. Joint welding is carried out using hot air.
Features and benefits:
Substrates:
Can be used on the following:
Manufacturer recommends that at least one additional overflow is installed into the parapet for protection.
Finish | Anti-slip Guidance for specification option: Embossed surface with anti-slip texture. |
Material | Guidance for specification option: Manufactured from polyvinyl chloride (PVC) with a core of polyester reinforcement. |
Warranty description | Guidance for specification option: Inclusive system warranty available, consult manufacturer. |
Uniclass | |
CAWS | J42/10 Warm deck roof covering J42/110 Warm deck roof covering |
Product Reference | Protan BlueProof Adhered - Warm Roof System |
Width | 2000 mm. As manufacturer's recommendations. |
Thickness | 1.8 mm. |
Weight | ≥2.1 kg/m² (plus fleece weight). |
Foldability at low temperature (to EN 1107-2) | ≤−30°C. |
Dimensional stability (to EN 1107-2) | ≥-0.5 and ≤0.5%. |
Water tightness (to EN 1928) | Pass. |
Resistance to tearing (EN 12310-2) | ≥450/300 N. |
Tensile strength (to EN 12311-2) | ≥1800/1400 N/50 mm. |
Elongation at break (to EN 12311-2) | ≥15%. |
Peel resistance of joints (to EN 12317-2) | ≥150 N/50 mm. |
Shear resistance of joints (to EN 12317-2) | ≥1000 N/50 mm. |
Water vapour resistance (to EN ISO 12572) | 27 m. |
Colour | Dark grey. |
Protan BlueProof System - Warm Roof Construction Mechanically Fixed - BP Membrane
Protan Prefabricated System - SE Membrane - Warm Roof Construction
Protan UK Adhered System - EX-A Membrane - Warm Roof Construction
Protan UK BlueProof Vacuum BP membrane - Warm Roof System
Protan UK Green Roof System Prefabricated G Membrane - Warm Roof Construction
Protan UK Protected System - Prefabricated G Membrane - Warm Roof Construction
Protan UK Standard Overlap System - SE Membrane - Warm Roof Construction
Protan UK Vacuum System - SE and EX-A membranes - Warm Roof Construction