Liquid Gas Membrane
Horizontal substrates, such as pile caps, require a single 1 coat application at a minimum WFT (Wet Film Thickness) of 1mm. Vertical substrates should have two coats applied. Hydroprufe LG should be applied using a suitable brush, roller, or airless spray equipment and where a mechanical key is required to promote adhesion to subsequently cast concrete, then a quartz aggregate should be broadcast into the wet coating. Once the coating has dried, then the excess aggregate should be swept or blown from the surface.
Color | Red |
Finish | Epoxy |
Material | Epoxy |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
WarrantyDescription | 25 year |
Uniclass | |
CAWS | J30/10 Cold-applied damp-proofing J30/130 Cold-applied damp-proofing |
Product range |
Modifier | Polymer modified. |
Curing time | 24 hours (at 20°C). |
Methane transmission rate | 30 ml/M²/day. |
Elongation at break | 100%. |
Water resistance | 0.6 bar. |
Adhesion to concrete | 1 N/mm². |
Application temperature | 5–30°C. |