NBS Source
I'm a manufacturer

+point® ICCP System - Corrosion Management System: Restoration

Verified by manufacturer 4 months ago

C-Probe Systems

Impressed current cathodic protection (ICCP) anode to pass protection current to the structural steel frame of transitional era (1890–1950) buildings, and masonry clad steel frame buildings.

Jump to:
+44 (0) 1744 611 555 Website

Application

Corrosion protection of structural steel frames within transitional era (1890–1950) buildings which are commonly affected by structural deterioration otherwise known as Regent Street Disease.

Installed using a conventional repointing gun and finishing tools.

Description

Impressed current cathodic protection (ICCP) anode.

Installed using a conventional repointing gun and finishing tools. Operates behind the heritage mortar finish to pass protection current to the structural steel frame of transitional era (1890–1950) buildings and masonry clad steel frame buildings which are commonly affected by structural deterioration otherwise known as Regent Street Disease.


Features and benefits:

  • For permanent and continuous operation.
  • Single lifetime application.
  • Service life tracking and compliance with ICCP standards via AiMS facility.
  • Provides greater flexibility with the design parameters that influence service life.
  • Reduces cost of traditional repair.
  • Contributes to NetZero initiatives through products and systems that are Environmental Social Governance (ESG) compliant.
  • Control zones provide remote access to performance data from embedded sensors and probes to remotely control the current and voltage provided to each zone within the property.
  • A continuous record of performance is provided with C-Probe's online service live tracking facility.


Components:

  • +point® anode mortar
  • CP200 corrosion rate probes (four per zone)
  • AchillesICP power, control and monitoring network
  • Electrical connections, wiring and environmentally-protected enclosure
  • a.c. and broadband connectors at the NAU.
  • AiMS facility for ongoing performance management and reporting.

General information

Uniclass

Ss_20_70_10_27 Embedded impressed current anode systemsPrimary

CAWS

C42/305 Proprietary repair systems

Specification data - Embedded impressed current anode systems

System performance

Guidance for specification option:

Insert requirements or omit.

System reference

Guidance for specification option:

Insert details.

Standards

Anode is manufactured by C-Probe and compliance tested at anode source to meet: ISO 12696:2016, BSI PAS 8820:2016 and is designed to meet ISO 15257:2019 by Structural Healthcare.

Products

Guidance for specification option:

Consult manufacturer and insert requirements.

Components:

  • +point® anode mortar
  • CP200 corrosion rate probes (four per zone)
  • AchillesICP power, control and monitoring network
  • Electrical connections, wiring and environmentally-protected enclosure
  • a.c. and broadband connectors at the Network Access Units (NAU).
  • AiMS facility for ongoing performance management and reporting.


Achilles interactive Management Server (AiMS):

To provide resilience information and service life tracking for the whole life performance of the protected asset.

Sustainability data

Contains Red List materials

Yes

Country of material origin

United Kingdom

Country of product manufacture

United Kingdom

Literature

Achilles interactive Management Server (AiMS) - Online Control and Monitoring of Your Structure

Achilles interactive Management Server (AiMS) - Online Control and Monitoring of Your Structure

+point® - ICCP System for Stone and Brick Clad Heritage Buildings

+point® - ICCP System for Stone and Brick Clad Heritage Buildings

Background to Corrosion for Heritage Buildings

Background to Corrosion for Heritage Buildings

Case studies

Historic Restoration - Terry's Chocolate Factory York

Historic Restoration - Terry's Chocolate Factory York

Historic Restoration - 230 Park Avenue (The Helmsley Building)

Historic Restoration - 230 Park Avenue (The Helmsley Building)

Historic Restoration - Concourse Village Plaza, New York City

Historic Restoration - Concourse Village Plaza, New York City

Similar products from C-Probe Systems

+chase® - ICCP System for Reinforced Concrete Structures - Corrosion Management System: Restoration

+chase® - ICCP System for Reinforced Concrete Structures - Corrosion Management System: Restoration

LoCem® Modular Anode Unit (MAU) - ICCP System - Corrosion Management System: New Build

LoCem® Modular Anode Unit (MAU) - ICCP System - Corrosion Management System: New Build