NBS Source
I'm a manufacturer

Plaza

Verified by manufacturer 8 months ago

Knauf UK Third party certifications:
  • EPD

    EPD

    Certificate type

Edge A gypsum acoustic ceiling tile in an exposed grid ceiling system.

Jump to:
0800 521 050 Website

Application

Recommended use in various construction projects, such as within the education sector due to the acoustic performance, up to 0.90 NRC, and the increased air quality certified according to the Danish Indoor Climate Labelling.

Description

Demountable gypsum acoustic ceiling tile in an exposed grid ceiling system.


Features and benefits:

  • An acoustic gypsum ceiling tile designed with a straight edge for installation in an exposed T-grid system, ensuring a highly robust, clean cut looking, suspended ceiling.
  • Fast and easy to mount and adapt, as all edges remain hidden above the grid system.
  • No issue of tile re-alignment.
  • Perforations options available: Globe (GI), Micro (M1), Quadril (Q1), Tangent (T1), Plain (P), Unity 3, Unity 4 and Unity 8/15/20.
  • Demountable for access to services.
  • Class C sound absorption (Class B with Tangent and Unity 3 perforations)
  • Aesthetic options of border around the perforations (standard range) or perforations right up to edge (unity range).

General information

Color

White

Finish

Painted

Material

Gypsum

Guidance for specification option:

Glass fibre reinforced.

Length

600 mm

Width

600 mm

Height

9.5 mm

12.5 mm

Uniclass

Ss_30_25_22_51 Modular suspended ceiling systemsPrimary

CAWS

K40/10 Unit/ modular suspended ceilings

K40/115 Unit/ modular suspended ceiling system

K40/135 Board-suspended ceiling system

K40/265 Infill units

Product range

Danoline

Specification data - Modular suspended ceiling systems

System performance

Acoustic performance.

Ceiling support

Demountable suspended ceiling grids.

Support fasteners

As schedule.

As drawing.

Guidance for specification option:

Insert drawing reference number.

Guidance for specification option:

  • For sizes up to 625 x 625 not in Tangent perforation, units of up to 3 k.g. can be installed directly into the panel without reinforcement.
  • For larger module sizes and all sizes with Tangent perforation a reinforcement panel of sufficient strength can be installed behind the tile.
  • The reinforcement panel must extend all the way into the main runners, so that the weight is transferred to them.
  • The total weight should not be greater than 3 k.g. for each m² of ceiling.
  • Where loads are greater than 3 k.g./m², additional hangers must be used.
  • Units over 3 k.g., should be installed independently, so that they do not place any load on the ceiling.


Insert additional requirements; contact manufacturer for more information.

Ceiling units

Glass fibre reinforced gypsum tiles.

Samples required

Not required.

Required.

Guidance for specification option:

Insert requirements; contact manufacturer for more information.

Grid

15 mm lay-in.

24 mm lay-in.

Hangers

Standard suspension wire.

Adjustable hanger.

Finishing

Pre painted white.

Fire safety

A2-s1, d0.

Light reflectance

69.2-82.6%.

Guidance for specification option:

Depending on perforation design in accordance with DIN 5036.

Weight

7.8-8.7 k.g./m² (for 9.5 mm) / 9-9.9 k.g./m² (for 12.5 mm).

Surface pattern

Plain (P).

Micro (M1) - (square 3 x 3 mm).

Globe (GI) - (circles Ø 6 mm).

Quadril (Q1) - (square 12 x 12 mm).

Tangent (T1) - (obround 4 x 14 mm).

Show more

Edge profile

A.

A+.

Grid system

Exposed T-grid with cross tees and hangers.

Fixing into substrates

As per site requirements.

Guidance for specification option:

Fixings are used to meet performance constraint confirmation is required from supplier to meets ceiling specification and any additional loading.


Insert requirements; contact manufacturer for more information.

Construction

As schedule.

As drawing.

Guidance for specification option:

Insert drawing reference number.

Guidance for specification option:

  • Suspension hangers: Knauf 25 x 25 mm angle section at 1200 mm centres, (first angle maximum 400 mm from wall).
  • Primary support channel: Knauf 38 mm deep 15 T-grid primary runner at 1200 mm centres (first runner maximum 600 mm from wall).
  • Cross tees: Knauf 38 mm deep 15 T-grid cross tees at 600 mm centres (cross ties available in 1200 mm and 600 mm lengths).
  • Perimeter channel: Use Knauf 20 X 24 mm wall angle or Knauf MS15 shadow line trim (creating 15 mm shadow gap) fixed at 300 mm centres.


Insert additional requirements; contact manufacturer for more information.

Tile size

600 x 600 x 9.5 mm.

600 x 600 x 12.5 mm.

Sustainability data

Country of material origin

Denmark

Country of product manufacture

Denmark

Material

Gypsum

Guidance for specification option:

Glass fibre reinforced.

Recyclability

-

Manufacturer guidance

Recyclable.

Third party certifications

Third party certifications

EPD

EPD

Knauf Plaza Perforated EPD

Literature

Knauf Acoustic and Design Solutions For Hospitals and Healthcare Facilities

Knauf Acoustic and Design Solutions For Hospitals and Healthcare Facilities

Similar products from Knauf UK

Belgravia

Belgravia

Contur

Contur

Corridor 400

Corridor 400

Danotile

Danotile