This site uses cookies to store information on your computer. Learn more about these cookies, and how to opt out of them. Find out more
50 mm.
BBA Agrément Certificate
Certificate type
Low lambda non-combustible stone wool insulation for ventilated facades.
NyRock® Rainscreen 032 is a stone wool insulation product specifically developed for use within ventilated cladding systems, as well as sealed systems such as curtain walling.
Manufactured using patented technology, NyRock Rainscreen 032 has a more efficient fibre structure that increases the density of air pockets trapped within each slab. This results in an improved thermal performance when compared to traditional stone wool products.
Once installed, the product’s high density works in combination with a factory applied water repelling agent to give improved resistance to rain ingress during construction.
The product can be fitted around brackets and other awkward details, and when tightly butted, adjacent slabs effectively ‘knit’ together to provide a continuous insulating layer, reducing heat losses that would otherwise be caused by gaps.
For optimum thermal performance in framed structures, combine NyRock Rainscreen Slab 032 with NyRock Frame Slab 032.
Features and benefits:
For use on steel frame, timber frame, or masonry walls in
conjunction rainscreen cladding:
For use on steel frame or timber frame with a brick outer leaf:
Material | Stonewool |
Shape | Rectangle |
Length | 1200 mm |
Width | 600 mm |
Height | 50 mm 55 mm 60 mm 65 mm 70 mm |
Uniclass | |
CAWS | H92/776 Thermal insulation P10/217 Insulation slabs fixed to backing wall H11/110 Curtain walling H11/780 Thermal insulation P10/42 Mineral wool insulation slabs fixed to backing wall |
Standard | To EN 13501-1, BS EN 13162. |
ThicknessConsult manufacturer's literature for example U-values based on various cladding systems, with or without NyRock Frame Slab 032. | 50 mm. |
Edges | Square. |
Density | Manufacturer's standard. |
Thermal conductivity (maximum) | 0.032 W/m·K. |
Compressive strength (minimum) | Manufacturer's standard. |
Fire performance | To BS EN 13501-1, A1. |
Sound insulation rating | Manufacturer's standard.Consult manufacturer's literature for details. |
Vapour resistivity | 5.9 MNs/gm. |
Cavity barriersInsert requirements. Manufacturer recommends the use of SP Firestop vertically and SP Firestop or SP Firestop OSCB horizontally, depending on outer leaf. Consult manufacturer's literature for details. | - |
FixingTo be secured to the substrate with metal and polypropylene fixings; consult manufacturer's literature for details and insert requirements. Horizontal joints should be staggered and all joints tight butted. | - |
Platform | Compatible | Version | Certified to |
---|---|---|---|
![]() | - | 1 | 2.1 |
![]() | - | 1 | 2.1 |
HARDROCK® UB34
NyRock® Cavity Slab 032 - Masonry Cavity Wall Insulation
NyRock® Frame Slab 032 - Insulation
ROCKWOOL® Acoustic Infills
ROCKWOOL® Fire Barrier Slab
ROCKWOOL® FIREPRO® Ablative Coated Batt
ROCKWOOL® FLEXI®
ROCKWOOL® HARDROCK® Multi-Fix (DD)
ROCKWOOL® HP Partial Fill Cavity Slabs - Insulation
ROCKWOOL® Insulation Slabs – RWA45, RW3, RW4, RW5 and RW6