Verified by manufacturer 4 months ago
Specialist pump system for use with Cavity Drain Waterproofing.
This product is designed to be used with cavity drain waterproofing, Type C cavity drain waterproofing system.
Specialist pump system that can be used with single pumps, twin pumps and twin pumps with twin discharge lines for greater pump efficiency.
The adjustable neck allows for the sump to be installed at a fixed height relative to the slab so that the connection in from the Newton drainage system and the pump discharge line are made above the concrete and always at the same height relative to the slab or raft.
The unique sump shape, together with a choice of inlet and outlet positions, allow for connections in and out of the chamber to be made to either a side wall, or to a corner.
Features and benefits:
Pump:
The Titan-Pro pumping system can be supplied with single or dual automatic or manual pumps, with single or dual pipe discharge lines.
Manual pumps must be matched to the Newton Pump Controller or Newton Control Panel-Pro.
Automatic pumps are supplied with Vertical Float Switches that allow for very flexible pump switching, allowing for adjustment of the ON and OFF positions of each pump, as well as the overall height of the pump switching. Please consult the manufacturer for further information.
Newton can supply the sump system as a whole or can supply the sump chamber and the fittings required for sump installation, separate to the pumps and High Water Level Alarm.
The internal pipe and fittings are included. External pipe and fittings in either 50 mm or 63 mm can be ordered as required.
Color | White |
Finish | Smooth |
Material | Stainless steel Guidance for specification option: Pumping System for Newton System 500. |
Shape | Other Guidance for specification option: Unique sump shape. |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Warranty description | Guidance for specification option: Chamber - Guaranteed against deterioration |
Uniclass | |
CAWS | J40/386 Cavity drainage sumps J40/388 Cavity drainage sumps with integral pumps R12/135 Private packaged pumping stations and pressure pipeline system R18/310 Package pumping stations |
Product range |
Collection tank | |
Configuration | Specified by Newton Specialist Basement Contractor. |
Pumps | |
Impeller | Pump dependent. |
Non-return valve | Internal pipework includes 50 mm valve. |
Connections | |
Inlet diameter | 63 mm pipework.Guidance for specification option: Code TPK3 |
Outlet diameter | 50 or 63 mm pipework included with the chamber.Guidance for specification option: Code TPK8 |
Product Reference | Newton CP250 (P29) Guidance for specification option: 250 W manual pump. Newton CP250 (P31) Guidance for specification option: 250 W automatic pump with vertical float suitable for ground and surface water. Newton CP400 (P28) Guidance for specification option: 400 W manual pump. Newton CP400 (P32) Guidance for specification option: 400 W automatic pump with vertical float suitable for ground and surface water. Newton NP400 (P2/ P3) Guidance for specification option: 400 W automatic/ manual pump with vertical float suitable for ground and surface water. |
Control panel | Newton Control Panel-Pro (CP2). Guidance for specification option: Supplied with a vertical water level float switch and water high alarm float switch. Newton Control Panel Pro and pre-fitted Newton Dialer (CP7). Guidance for specification option: Supplied with a vertical water level float switch and water high alarm float switch. Newton Pump Controller (CP9). Guidance for specification option: Supplied with a vertical water level float switch and water high alarm float switch. |
Integral accessories | Newton Dialer (PA5). Guidance for specification option: Can send either text or voice messages to up to five designated phones should an alarm condition occur. Anti-Drip Kit (TPK1). Anti-Smell Kit (TPK7). Wall flange for 63 mm inlet (TPO1). Wall flange for 110 mm inlet (TP02). |
Frame/ lid | Alulite, triple-sealed recessed lid (TPSL7). Guidance for specification option: 600 x 600 mm, with 450 x 450 mm opening. Brass edged, recessed lid (TPSL4). Guidance for specification option: 600 x 600 mm, with 450 x 450 mm opening. Galvanized steel frame, recessed lid (TPSL2). Guidance for specification option: 600 x 600 mm, with 450 x 450 mm opening. Stainless steel edged, recessed lid (TPSL3). Guidance for specification option: 600 x 600 mm, with 450 x 450 mm opening. |
Power converter | MultiPlus 12/800/35 (BB1). Guidance for specification option: Battery backup facility for pumps of 150 W and 250 W. MultiPlus 12/1200/50 (BB2). Guidance for specification option: Battery backup facility for pumps of 400 W. MultiPlus 12/3000.120 (BB3). Guidance for specification option: Battery backup facility for pumps of 750 W. Quattro 12/3000/120 (BB4) Guidance for specification option: Battery backup facility for all pumps up to 750 W. |
Standby batteries | 60 Ah High Efficiency battery (BB20). 101 Ah High Efficiency battery (BB21). 201 Ah High Efficiency battery (BB22). |
Alarm: | High Water Level Alarm (PA50). Guidance for specification option: Switch not suitable for regular contact with sewage. |
Contains Red List materials | No |
Recyclability | 0 |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 0 % |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
IFC2X3 | 7 | |
Revit 2016 | 8 |