Alarm which detects high water levels within pump chambers.
Provides alarm function for single or twin pump systems where no control panel is installed.
The Newton High Level Water Alarm (PA50) has been designed to detect high water levels within pump sump chambers, and is included within the Newton Titan-Pro and Newton Titan pumping systems. The alarm is powered by a standard 9V PP3 battery.
It can be programmed to automatic reset or manual reset after an alarm occurrence. A mute button to the front face silences the alarm once the alarm condition is discovered. A flashing alarm light gives visual indication of an alarm condition, and this light will continue to show even when the alarm sounder is muted.
When the unit is to be used within a single pump system, the alarm switch should be positioned just above the point where the single pump should start pumping. When used within a twin pump system, the switch should be set at a height above the point of the start of the lower pump but below the point where the secondary pump would ordinarily start.
Features and benefits:
Application:
Provides alarm function for single or twin pump systems where no control panel is installed.
Features | Auto or manual reset options, surface mounting or flush mounting to standard electric back box, battery powered and loud 90 dB alarm, mute button |
Size | 152 x 92 x 37 mm (8.00 mm if mounted in back box) (w x h x depth) |
WarrantyDescription | The alarm is supplied with a one-year back-to-base warranty which is dated from either the date of purchase or a proven date of installation. If the unit develops a fault during the warranty period, Newton Waterproofing Systems will repair or replace the unit under warranty. Consult manufacturer for a returns form which explains the returns procedure. The warranty will be invalidated if the unit is damaged because of improper handling, storage, or installation and in such cases a repair charge may be applicable |
Uniclass 2015 | |
CAWS | J40/290 High density polyethylene/ polypropylene studded cavity drain membrane R12/135 Private packaged pumping stations and pressure pipeline system R18/310 Private packaged pumping stations |
Product Reference | Newton High Water Alarm (PA50) |
Pumps | - |
Configuration | Single pump systemthe alarm switch should be positioned just above the point where the single pump should start pumping. Twin pump systemthe switch should be set at a height above the point of the start of the lower pump but below the point where the secondary pump would ordinarily start |
Pump characteristic | High Water Alarm which is included within the Newton Titan-Pro and Newton Titan pumping systems |
Control | Provides alarm function for single or twin pump systems where no control panel is installed |
Integral accessories | Newton text and speech Dialer (PA5) |
Weight | 700 g |
Power supply | 9 V - PP3 battery (supplied) |
Sounder volume (dB) | 90 (at 1000 mm) |
Switching | Reed switch |
Standard product features | Colour: Blue. Features: Auto or manual reset options, surface mounting or flush mounting to standard electric back box, battery powered and loud 90 dB alarm, mute button. Size: 152 x 92 x 37 mm (8.00 mm if mounted in back box) (w x h x depth). Warranty description: The alarm is supplied with a one-year back-to-base warranty which is dated from either the date of purchase or a proven date of installation. If the unit develops a fault during the warranty period, Newton Waterproofing Systems will repair or replace the unit under warranty. Consult manufacturer for a returns form which explains the returns procedure. The warranty will be invalidated if the unit is damaged because of improper handling, storage, or installation and in such cases a repair charge may be applicable. |