BBA Agrément Certificate
Certificate type
Monarplan is a flexible PVC-P single ply membrane offering excellent characteristics of strength, elongation and weathering making it ideal for new build or refurbishment projects.
All membranes are reinforced and are available with or without a fleece backing providing scope for all methods of application and offering specifiers confidence in performance and unlimited freedom in design.
Mechanically Fastened System:
Monarplan FM systems rely on the use of fasteners and pressure plates installed at pre-determined centres within the overlap to attach the roofing system to the structure. The system offers fast application time, instant seam strength and reduced impact associated with inclement weather conditions. Monarplan FM membrane is mechanically attached through to the structural deck using Monarplan Tubular Fasteners of appropriate length. The fasteners are required to penetrate through the structural deck with a minimum projection to the underside of 25 mm.
Fully Adhered System:
Monarplan GF Fleecebacked membrane offers an ideal solution on very complex building shapes or where drilling and mechanical fasteners are inappropriate or impractical.
Warm Ballasted System:
Monarplan G membrane offers an ideal solution on very complex building shapes or where drilling and mechanical fasteners are inappropriate or impractical, and is fast to installation but can support the increased loading from the ballast material.
Components:
Uniclass 2015 | |
CAWS | J42/110 Warm deck roof covering |
Product Reference | Monarplan Warm Deck Roofing System |
Primer | Not requiredIcopal S.A. PrimerQuick drying primer for self-adhesive membranes. |
Vapour control layer | Not requiredMicoral NB vapour control layerHeat-activated/ self-adhesive bituminous vcl for mechanically fastened systems only. TorchSafe T.A. VCL - SandHeat-activated/ self-adhesive bituminous vcl. Monofilament 250 vapour control layerLoose-laid polyethylene vcl (low-med humidity). For mechanically fixed systems only. Reflex 275 vapour control layerLoose-laid polyethylene vcl (med-high humidity). For mechanically fixed systems only. |
Insulation | - |
Type | Thermazone FoilboardFoil-faced insulation for mechanically fixed single-ply systems. Thermazone RoofboardFor adhered, warm ballasted or mechanically fixed single-ply systems. |
Fixing | Adhered with Icopal Insulation AdhesiveMechanically fastened, with fixings as clause 355 |
Waterproof membrane | - |
Type | Monarplan FMMechanically fixed systems only. Monarplan GWarm ballast systems only. Monarplan GFFully adhered systems only. |
Fixing | Adhered with Icopal Fleeceback AdhesiveAdhered with Icopal SBR Spray Contact AdhesiveLoose-laid with sealed lapsWarm ballasted systems. Mechanically fastened, with fixings as clause 355 |
Thickness | 1.2 mmMonarplan FM only. 1.5 mm1.8 mmMonarplan FM only. |
Colour | Anthracite (RAL 7015)Light Grey (RAL 7001) |
Surface protection | Not requiredMechanically fixed/ fully adhered systems. 20-40 mm diameter river-washed stone ballast50 mm concrete paving slabs on supports/pads |
Accessories | NoneIcopal PVC Cable and Tube DuctIcopal PVC Cowled Telescopic VentIcopal PVC Lightning Conductor PadsIcopal PVC OutletIcopal PVC Parapet OutletIcopal PVC Standing Seam Profile, as clause 450Icopal PVC Walkway Membrane, as clause 485 |
Product Options | Preparation: Consult with Icopal Ltd for details of the preparation and priming of the intended roof structure and substrate and for details of the requirements for preparation layers, venting layers, nailing layers and taping strips. System build-up: Consult Icopal Limited’s technical literature for details and guidance. Icopal Limited are also able to offer a design and specification service and it is recommended that they are consulted early in the design process. |