Verified by manufacturer 6 months ago
U1-N90-B22 - 90 mm stud
BES 6001
Certificate type
BSI Kitemark
Certificate type
EPD
Certificate type
ISO 9001 Quality Management
Certificate type
ISO 14001 Environmental Management Systems
Certificate type
CCPI System
Certificate type
Metsec SFS infill wall with Euroform Versaroc sheathing board, Rockwool Duo Slab insulation and British Gypsum lining (12.5 mm).
SFS infill wall with insulation and plasterboard lining.
Metsec SFS infill wall with Euroform Versaroc sheathing board, Rockwool Duo Slab insulation and British Gypsum lining (12.5 mm).
Fire performance: Up to 120 minutes.
DXXX-U1-N90-B22, DXXX-U1-N100-B22, DXXX-U1-N120-B22, DXXX-U1-N150-B22, DXXX-U1-N180-B22, DXXX-U1-N210-B22, DXXX-U1-N240-B22, DXXX-U1-N270-B22, DXXX-U1-N300-B22, DXXX-U1-N350-B22
Finish | Galvanized Guidance for specification option: Steel. |
Material | Steel Plasterboard |
Shape | Other |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Warranty description | 30 year |
Uniclass | |
CAWS | G10/20 Steel framing system G10/150 Steel framing system |
Product range |
System performance | Structural design supervision and checking. |
Framing members | Cold-formed galvanized steel sections. |
Connections | |
Connection fasteners | Self drilling tek screws. |
Anchors to concrete and masonry | |
Type of anchor | By structural engineers design. |
Movement joints | Deflection allowance at the top of the wall. |
Insulation | External: Rockwool Duo Slab; between framing: n/a. Guidance for specification option: Insert requirements for Duo Slab external insulation thickness (minimum 75 mm). External: Rockwool Duo Slab; between framing: ___. Guidance for specification option: Insert requirements for:
|
Sheathing board | Euroform Versaroc - 12 mm. |
Framing | Metsec SFS 90 mm stud depth. Manufacturer guidanceTypically at 600 mm centres. |
Inner layer | British Gypsum Fire Board, 12.5 mm. |
Face layer | British Gypsum Fire Board, 12.5 mm. |
Fasteners | Drywall screws. |
System accessories | Flatstrap / partition brace. Guidance for specification option: Required behind horizontal board joints. |
Internal face | 120/ 120 minutes (insulation/ integrity). |
External face | 120/ 120 minutes (insulation/ integrity). |
Fire performance | 120 minutes (boundary wall); 120 minutes (non-boundary wall). |
Thermal performance (U-value maximum) | Variable. |
Air tightness | Variable. |
Dimensional constraints | Variable. Guidance for specification option: Consult manufacturer for details based on overall specification. |
Contains Red List materials | No |
Country of product manufacture | United Kingdom |
Recyclability | SFS Light Gauge Steel 95-100% |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 60 % |
BES 6001
BES 6001 Responsible Sourcing of Construction Products
BSI Kitemark
BIM Level 2 Kitemark - For Design and Construction Phase
BSI Kitemark
BSI Kitemarkâ„¢ for BIM Objects
EPD
Environmental Product Declaration EPD - SFS
ISO 9001 Quality Management
ISO 9001:2015 Quality Management System
BSI Kitemark
UKCA Certificate of Conformity of the Factory Production Control
ISO 14001 Environmental Management Systems
ISO 14001:2015 Environmental Management System
CCPI System
CCPI Light Gauge Steel Framing Systems
Metsec’s lightweight steel framing system, SFS, is being used in the creation of a new £346m riverside residential development in the Barking and Dagenham area of London
Metsec’s SFS steel framing system has helped to create a seamless finish to the façade of a new state-of-the-art custody centre and strategic policing hub for Devon and Cornwall Constabulary.
Metsec SFS Infill Wall with CORETEX Sheathing Board, BG Internal Boards, Fire performance 90 min (non boundary)
Metsec SFS Infill Wall with CORETEX Sheathing Board, BG Internal Boards, Rockwool Duo Slab, Fire performance 120 min
Metsec SFS Infill Wall with Densglas Sheathing Board, BG Internal Boards, Fire performance 90 min (non boundary)
Metsec SFS Infill Wall with Easyboard Sheathing Board, BG Internal Boards, Fire performance 60 min
Metsec SFS Infill Wall with G-Board Sheathing Board, BG Internal Boards, Fire performance 120 min (non boundary)
Metsec SFS Infill Wall with Glasroc X Sheathing Board, BG Internal Boards, Fire performance 120 min (non boundary)
Metsec SFS Infill Wall with Glasroc X Sheathing Board, BG Internal Boards, Knauf Rocksilk, Fire performance 90 min (non boundary)
Metsec SFS Infill Wall with Glasroc X Sheathing Board, BG Internal Boards, Rockwool Duo Slab, Fire performance 120 min (non boundary)
Metsec SFS Infill Wall with Multipurpose Sheathing Board, BG Internal Boards, Fire performance 90 min (non boundary)
Metsec SFS Infill Wall with Versaroc Sheathing Board, BG Internal Boards, Fire performance 120 min (non boundary)